Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The objective of this study was to evaluate the performance of a new version of quantusFLM®, a software tool for prediction of neonatal respiratory morbidity (NRM) by ultrasound, which incorporates a fully automated fetal lung delineation based on Deep Learning techniques. A set of 790 fetal lung ultrasound images obtained at 24 + 0–38 + 6 weeks’ gestation was evaluated. Perinatal outcomes and the occurrence of NRM were recorded. quantusFLM® version 3.0 was applied to all images to automatically delineate the fetal lung and predict NRM risk. The test was compared with the same technology but using a manual delineation of the fetal lung, and with a scenario where only gestational age was available. The software predicted NRM with a sensitivity, specificity, and positive and negative predictive value of 71.0%, 94.7%, 67.9%, and 95.4%, respectively, with an accuracy of 91.5%. The accuracy for predicting NRM obtained with the same texture analysis but using a manual delineation of the lung was 90.3%, and using only gestational age was 75.6%. To sum up, automated and non-invasive software predicted NRM with a performance similar to that reported for tests based on amniotic fluid analysis and much greater than that of gestational age alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Note on the Sampling Error of the Difference Between Correlated Proportions or Percentages
McNemar, Q. (1947) · Psychometrika · doi:10.1007/bf02295996 · Cited by 4,754
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157 · cited 1×
“Automatic medical ultrasound image segmentation has been widely studied 33,34 , with notable success examples such as prostate 35 or breast cancer images 36 .”
BackgroundAntenatal Betamethasone for Women at Risk for Late Preterm Delivery
Gyamfi-Bannerman, C., Thom, E. A., Blackwell, S. C., Tita, A. T. N., Reddy, U. M., Saade, G. R., Rouse, D. J., McKenna, D. S., Clark, E. A. S., Thorp, J. M., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1516783 · Cited by 814
Timing of Indicated Late-Preterm and Early-Term Birth
Spong, C. Y., Mercer, B. M., D'Alton, M., Kilpatrick, S., Blackwell, S., & Saade, G. (2011) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3182255999 · Cited by 581
Alexander, N., Rosenlöcher, F., Stalder, T., Linke, J., Distler, W., Morgner, J., & Kirschbaum, C. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1970 · Cited by 211
Carneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.928917 · Cited by 205
Quantitative ultrasound texture analysis of fetal lungs to predict neonatal respiratory morbidity
Bonet‐Carne, E., Palacio, M., Cobo, T., Perez‐Moreno, A., Lopez, M., Piraquive, J. P., Ramirez, J. C., Botet, F., Marques, F., & Gratacos, E. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13441 · Cited by 85
Self-citation
Cited by
Burgos-Artizzu, X. P., Coronado-Gutiérrez, D., Valenzuela-Alcaraz, B., Bonet-Carne, E., Eixarch, E., Crispi, F., & Gratacós, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-67076-5 · Cited by 240
“Operator 1 (874) Operator 2 (946) Operator 3 (1,460) ALL (5,271)”
Self-citationMachine Learning in Fetal Cardiology: What to Expect
Garcia-Canadilla, P., Sanchez-Martinez, S., Crispi, F., & Bijnens, B. (2020) · Fetal Diagnosis and Therapy · doi:10.1159/000505021 · Cited by 123
Use of artificial intelligence and deep learning in fetal ultrasound imaging
Ramirez Zegarra, R., & Ghi, T. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26130 · Cited by 102
“The application of DL is beginning to expand, with DL algorithms able to detect other fetal structures, such as the face 112–114 , spine 115 , kidneys 116,117 , lungs 118–120 , adipose tissue 121,122 and sexual organs 123 .”
BackgroundArtificial intelligence in obstetric ultrasound: A scoping review.
Horgan, R., Nehme, L., & Abuhamad, A. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6411 · Cited by 72
Artificial Intelligence in Prenatal Ultrasound Diagnosis
He, F., Wang, Y., Xiu, Y., Zhang, Y., & Chen, L. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.729978 · Cited by 62
Metadata
- Authors
- Burgos-Artizzu, X. P., Perez-Moreno, Á., Coronado-Gutierrez, D., Gratacos, E., & Palacio, M.
- Venue
- Scientific Reports
- Published
- 2019-02-13
- Volume
- 9
- Issue
- 1
- Pages
- 1950-1950
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2923700253
- Cited by
- 51
- References
- 8
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis. https://app.cochat.ai/papers/10.1038/s41598-019-38576-w
- The paper
- Burgos-Artizzu, X. P., Perez-Moreno, Á., Coronado-Gutierrez, D., Gratacos, E., & Palacio, M. (2019). Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis. Scientific Reports. https://doi.org/10.1038/s41598-019-38576-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.