A Low Cost and Portable Microwave Imaging System for Breast Tumor Detection Using UWB Directional Antenna array
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Globally, breast cancer is a major reason for female mortality. Due to the limitations of current clinical imaging, the researchers are encouraged to explore alternative and complementary tools to available techniques to detect the breast tumor in an earlier stage. This article outlines a new, portable, and low-cost microwave imaging (MWI) system using an iterative enhancing technique for breast imaging. A compact side slotted tapered slot antenna is designed for microwave imaging. The radiating fins of tapered slot antenna are modified by etching nine rectangular side slots. The irregular slots on the radiating fins enhance the electrical length as well as produce strong directive radiation due to the suppression of induced surface currents that radiate vertically at the outer edges of the radiating arms with end-fire direction. It has remarkable effects on efficiency and gain. With the addition of slots, the side-lobe levels are reduced, the gain of the main-lobe is increased and corrects the squint effects simultaneously, thus improving the characteristics of the radiation. For experimental validation, a heterogeneous breast phantom was developed that contains dielectric properties identical to real breast tissues with the inclusion of tumors. An alternative PC controlled and microcontroller-based mechanical MWI system is designed and developed to collect the antenna scattering signal. The radiated backscattered signals from the targeted area of the human body are analyzed to reveal the changes in dielectric properties in tissues. The dielectric constants of tumorous cells are higher than that of normal tissues due to their higher water content. The remarkable deviation of the scattered field is processed by using newly proposed Iteratively Corrected Delay and Sum (IC-DAS) algorithm and the reconstruction of the image of the phantom interior is done. The developed UWB (Ultra-Wideband) antenna based MWI has been able to perform the detection of tumorous cells in breast phantom that can pave the way to saving lives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Kuhl, C. K., Schrading, S., Leutner, C. C., Morakkabati-Spitz, N., Wardelmann, E., Fimmers, R., Kuhn, W., & Schild, H. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2004.00.4960 · Cited by 1,147
Ten-Year Risk of False Positive Screening Mammograms and Clinical Breast Examinations
Elmore, J. G., Barton, M. B., Moceri, V. M., Polk, S., Arena, P. J., & Fletcher, S. W. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381601 · Cited by 1,053
Microwaves for breast cancer detection?
Fear, E. C., Meaney, P. M., & Stuchly, M. A. (2003) · IEEE Potentials · doi:10.1109/mp.2003.1180933 · Cited by 487
Microwave System for Head Imaging
Mohammed, B. J., Abbosh, A. M., Mustafa, S. A., & Ireland, D. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2277562 · Cited by 405
27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(2005) · IEEE Transactions on Nanobioscience · doi:10.1109/tnb.2005.845677 · Cited by 288
Review of Terahertz Tomography Techniques
Guillet, J. P., Recur, B., Frederique, L., Bousquet, B., Canioni, L., Manek-Hönninger, I., Desbarats, P., & Mounaix, P. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-014-0057-0 · Cited by 254
Double-square frequency-selective surfaces and their equivalent circuit
Langley, R. J., & Parker, E. A. (1983) · Electronics Letters · doi:10.1049/el:19830460 · Cited by 244
A Wearable Microwave Antenna Array for Time-Domain Breast Tumor Screening
Porter, E., Bahrami, H., Santorelli, A., Gosselin, B., Rusch, L. A., & Popovic, M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2518489 · Cited by 216
Review of Electromagnetic Techniques for Breast Cancer Detection
Hassan, A. M., & El-Shenawee, M. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2169780 · Cited by 214
Cited by
A YOLOv3 Deep Neural Network Model to Detect Brain Tumor in Portable Electromagnetic Imaging System
Hossain, A., Islam, M. T., Islam, M. S., Chowdhury, M. E. H., Almutairi, A. F., Razouqi, Q. A., & Misran, N. (2021) · IEEE Access · doi:10.1109/access.2021.3086624 · Cited by 66
Self-citation
Metadata
- Authors
- Islam, M. T., Mahmud, M. Z., Islam, M. T., Kibria, S., & Samsuzzaman, M.
- Venue
- Scientific Reports
- Published
- 2019-10-29
- Volume
- 9
- Issue
- 1
- Pages
- 15491-15491
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2982550332
- Cited by
- 219
- References
- 14
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Low Cost and Portable Microwave Imaging System for Breast Tumor Detection Using UWB Directional Antenna array. https://app.cochat.ai/papers/10.1038/s41598-019-51620-z
- The paper
- Islam, M. T., Mahmud, M. Z., Islam, M. T., Kibria, S., & Samsuzzaman, M. (2019). A Low Cost and Portable Microwave Imaging System for Breast Tumor Detection Using UWB Directional Antenna array. Scientific Reports. https://doi.org/10.1038/s41598-019-51620-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.