Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index; none of the 26 sources its claims cite is checked for support yet.

Tracing multi-isotopically labelled CdSe/ZnS quantum dots in biological media

Open access

Abstract

The strengths and limits of isotopically labelled Engineered Nanoparticles (spiked ENPs) spread in biological media have been assessed. Multi-spiked CdSe/ZnS quantum dots (QDs), measuring 7 nm and coated with thioglycolic acid (TGA), were synthesized and enriched in 68 Zn, 77 Se and 111 Cd. These QDs were dispersed at very low concentrations (0.1 to 5000 ppt) in diverse biological matrices (synthetic saliva, synthetic urine, plasma and Dulbecco’s phosphate buffered saline - DPBS growth medium) and the isotopic compositions were determined by HR-ICP-MS. The initial QDs concentrations were calculated to assess the limit of quantification (QD-LOQ) according to the matrix and the isotopically enriched element. The obtained results demonstrated the advantages of the isotopic labelling method in order to work at very low concentrations: the QD-LOQ values for the spiked Zn, Cd and Se originated from the QDs were 10, 0.3 and 6 ppt, respectively, which is below the conventional LOQ of the HR-ICP-MS used (30, 3 and 60 ppt for Zn, Cd and Se, respectively). Conversely, in complex matrices such as saliva, urine, plasma and DPBS growth medium, the QD-LOQ values increased significantly, with values ranging from 16 to 32 ppt for Cd, 446 to 10598 ppt for Zn and 1618 to 8317 ppt for Se. These QD-LOQs are dependent on factors as the elemental background concentration already present in the matrices, and the dilution factor. In this study, the QD-LOQs are expressed for the first time with respect to the background concentration in biological media (QD-RLOQ), which can be used to better assess and then predict the efficiency of the spiking method.

Overview

CoChat Summary

TL;DR

Multi-isotopically labelled CdSe/ZnS quantum dots were synthesized and tested in biological matrices to determine HR-ICP-MS quantification limits. Isotopic labelling enabled detection below conventional LOQs in simple media, but QD-LOQs rose in complex matrices depending on background concentration and dilution.

Key findings

  • Multi-spiked CdSe/ZnS QDs enriched in 68Zn, 77Se and 111Cd, TGA-coated and measuring 7.6 ± 1.6 nm (n = 230), were dispersed at 0.1–5000 ppt in synthetic saliva, synthetic urine, rat plasma and DPBS growth medium.
  • In simple media, QD-LOQs were 10, 0.3 and 6 ppt for Zn, Cd and Se in HNO3 2%, and 7 and 2 ppt for Zn and Cd in NaNO3 0.01 M, below the conventional HR-ICP-MS LOQs of 30, 3 and 60 ppt for Zn, Cd and Se.
  • In biological matrices, QD-LOQs increased to 446–10598 ppt for Zn, 16–32 ppt for Cd and 1618–8317 ppt for Se; specific values were saliva 2275/20/1618 ppt, urine 5459/16/8317 ppt, plasma 10598/32/7291 ppt and DPBS 446/17/3388 ppt for Zn/Cd/Se.
  • Recovery rates were 93 ± 9.9% for Cd and 93 ± 10% for Zn, but only 11–79% for Se; QD-RLOQs in biological matrices ranged from 0.8–5.5% for Zn, 4–42% for Cd and 1.0–68% for Se, with Zn QD-LOQ correlated to background concentration (r² = 0.9957) and Cd QD-LOQ correlated to dilution factor (r² = 0.8237).

Methods

  • Multi-spiked CdSe/ZnS QDs were synthesized by adapting Bae et al., substituting 68Zn-enriched ZnO, 111Cd-enriched CdO and 77Se-enriched Se, then TGA-functionalized; characterization used UV-Vis, fluorescence, TEM, EDXS, ICP-OES and HR-ICP-MS.
  • QDs were added to synthetic saliva, synthetic urine, rat plasma, DPBS and control HNO3 2%/NaNO3 0.01 M at target Zn concentrations of 0.1, 10, 50, 100, 1000 and 5000 ppt (Cd 0.03–1500 ppt; Se 0.02–1000 ppt), with triplicates; samples were acidified and biological matrices diluted 50-fold before HR-ICP-MS analysis with Rh internal standard.
  • QD concentrations were calculated from isotopic contrast; recovery plots, RMSEP, t-tests at 99.9% confidence, ANOVA and linear models were used to determine QD-LOQs and factors affecting them, and QD-RLOQ was calculated as QD-LOQ/(QD-LOQ + background concentration) × 100.

Limitations

  • Stated: Se recovery was poor (11–79%) because Se required high-resolution ICP-MS and suffered polyatomic interferences, so Se QD-LOQs were not discussed further; QD-LOQ estimates were considered conservative because few experimental points were near the LOQ and RMSEP was calculated over several decades.
  • Stated: the study assesses analytical limits in selected matrices rather than in vivo fate or toxicity, and the authors note that the limitations of isotopic labelling for NPs in biological matrices had not previously been studied.
  • Evident from the text: only four matrices were tested, including artificial saliva and urine and rat plasma, all biological samples were 50-fold diluted, and the QD-RLOQ for Cd in DPBS could not be calculated because background Cd was below the HR-ICP-MS LOQ.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41598-020-59206-w

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 (a) TEM image of the multi-spiked CdSe/ZnS QDs dispersed in chloroform. (b) TEM image of the CdSe/ZnS TGA-coated QDs dispersed in Milli-Q® water. (c) Size distribution of the QDs estimated from (a)
Figure 1 (a) TEM image of the multi-spiked CdSe/ZnS QDs dispersed in chloroform. (b) TEM image of the CdSe/ZnS TGA-coated QDs dispersed in Milli-Q® water. (c) Size distribution of the QDs estimated from (a)CC BY · PubMed Central
Figure 2 Cpred vs. Cref recovery plots to estimate the concentration of the QDs based on the 111Cd tracer. The solid black line indicates the best linear fit and the dashed black line represents the ideal Cpred = Cref recovery plot.
Figure 2 Cpred vs. Cref recovery plots to estimate the concentration of the QDs based on the 111Cd tracer. The solid black line indicates the best linear fit and the dashed black line represents the ideal Cpred = Cref recovery plot.CC BY · PubMed Central
Figure 3 (a) Recovery rates grouped by tracer element for all matrices. (b) QD-LOQs grouped by tracer element for simple matrices (empty symbols) and complex matrices (filled symbols).
Figure 3 (a) Recovery rates grouped by tracer element for all matrices. (b) QD-LOQs grouped by tracer element for simple matrices (empty symbols) and complex matrices (filled symbols).CC BY · PubMed Central
Figure 4 QD-LOQs grouped by tracer element for the biological matrices (●) compared with the background concentration (BC) in the matrix (□) for the studied elements: (a) Zn, (b) Cd and (c) Se. The black circles (●) represent the QD-LOQs found for 50-fold diluted samples, whereas the white circles (o) indicate the non-diluted samples.
Figure 4 QD-LOQs grouped by tracer element for the biological matrices (●) compared with the background concentration (BC) in the matrix (□) for the studied elements: (a) Zn, (b) Cd and (c) Se. The black circles (●) represent the QD-LOQs found for 50-fold diluted samples, whereas the white circles (o) indicate the non-diluted samples.CC BY · PubMed Central
Figure 5 Global concept of the study.
Figure 5 Global concept of the study.CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 3 Not valid · 13 Not checked · 91 Own results and interpretations

57 more claims

Create a free account to see all 107 claims and to verify the 22 references still open.

See all claims — free account
  • It may state two separate claims as one. 26
  • Probably not a substantial claim. 21
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 35 references

Cited by

See all 10

Metadata

Authors
Supiandi, N. I., Charron, G., Tharaud, M., Benedetti, M. F., & Sivry, Y.
Affiliations
  • Centre National de la Recherche Scientifique (FR)
  • Université Paris Cité (FR)
Corresponding author
Sivry, Y.
Venue
Scientific Reports
Published
2020-02-18
Volume
10
Issue
1
Pages
2866-2866
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3007177044
Cited by
10
References
35
Citations by year
2022: 2 · 2021: 5 · 2020: 3
FWCI
0.98
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • HAL (submittedVersion, cc-by)
Funders
  • Agence Nationale de Sécurité Sanitaire de l’Alimentation, de l’Environnement et du Travail
  • Institut de Physique du Globe de Paris (12015908)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Heavy Metal Exposure and Toxicity
Keywords
CdSe/ZnS quantum dots, isotopic labeling, engineered nanoparticles, limit of quantification, 68Zn, 77Se, 111Cd, saliva, urine, plasma

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tracing multi-isotopically labelled CdSe/ZnS quantum dots in biological media. https://app.cochat.ai/papers/10.1038/s41598-020-59206-w
The paper
Supiandi, N. I., Charron, G., Tharaud, M., Benedetti, M. F., & Sivry, Y. (2020). Tracing multi-isotopically labelled CdSe/ZnS quantum dots in biological media. Scientific Reports. https://doi.org/10.1038/s41598-020-59206-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.