The application of deep learning based diagnostic system to cervical squamous intraepithelial lesions recognition in colposcopy images
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background Deep learning has presented considerable potential and is gaining more importance in computer assisted diagnosis. As the gold standard for pathologically diagnosing cervical intraepithelial lesions and invasive cervical cancer, colposcopy-guided biopsy faces challenges in improving accuracy and efficiency worldwide, especially in developing countries. To ease the heavy burden of cervical cancer screening, it is urgent to establish a scientific, accurate and efficient method for assisting diagnosis and biopsy. Methods The data were collected to establish three deep-learning-based models. For every case, one saline image, one acetic image, one iodine image and the corresponding clinical information, including age, the results of human papillomavirus testing and cytology, type of transformation zone, and pathologic diagnosis, were collected. The dataset was proportionally divided into three subsets including the training set, the test set and the validation set, at a ratio of 8:1:1. The validation set was used to evaluate model performance. After model establishment, an independent dataset of high-definition images was collected to further evaluate the model performance. In addition, the comparison of diagnostic accuracy between colposcopists and models weas performed. Results The sensitivity, specificity and accuracy of the classification model to differentiate negative cases from positive cases were 85.38%, 82.62% and 84.10% respectively, with an AUC of 0.93. The recall and DICE of the segmentation model to segment suspicious lesions in acetic images were 84.73% and 61.64%, with an average accuracy of 95.59%. Furthermore, 84.67% of high-grade lesions were detected by the acetic detection model. Compared to colposcopists, the diagnostic system performed better in ordinary colposcopy images but slightly unsatisfactory in high-definition images. Implications The deep learning-based diagnostic system could help assist colposcopy diagnosis and biopsy for HSILs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
He, K., Gkioxari, G., Dollar, P., & Girshick, R. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.322 · Cited by 29,137
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
Self-citationArtificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803 · cited 1×
“Studies in optical coherence tomography 17 , radiology 18 , computerized tomography scan 19 , colonoscopy 20 and pathologic slides 15 have indicated that computer algorithms can approach and even surpass the diagnostic accuracy of clinicians after training a large number of medical images in a…”
BackgroundHe, K., Gkioxari, G., Dollar, P., & Girshick, R. (2020) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2018.2844175 · Cited by 3,457
Coudray, N., Ocampo, P. S., Sakellaropoulos, T., Narula, N., Snuderl, M., Fenyö, D., Moreira, A. L., Razavian, N., & Tsirigos, A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0177-5 · Cited by 2,930
Deep learning algorithms for detection of critical findings in head CT scans: a retrospective study
Chilamkurthy, S., Ghosh, R., Tanamala, S., Biviji, M., Campeau, N. G., Venugopal, V. K., Mahajan, V., Rao, P., & Warier, P. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31645-3 · Cited by 1,020
Arbyn, M., Verdoodt, F., Snijders, P. J. F., Verhoef, V. M. J., Suonio, E., Dillner, L., Minozzi, S., Bellisario, C., Banzi, R., Zhao, F.-H., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70570-9 · Cited by 674
Natural history and epidemiology of HPV infection and cervical cancer
Castellsagué, X. (2008) · Gynecologic Oncology · doi:10.1016/j.ygyno.2008.07.045 · Cited by 590
Qiao, Y.-L., Sellors, J. W., Eder, P. S., Bao, Y.-P., Lim, J. M., Zhao, F.-H., Weigl, B., Zhang, W.-H., Peck, R. B., Li, L., et al. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70210-9 · Cited by 471
He, K., Gkioxari, G., Dollár, P., & Girshick, R. (2017) · arXiv · doi:10.48550/arxiv.1703.06870 · Cited by 406
Cited by
Artificial Intelligence in Cervical Cancer Screening and Diagnosis
Hou, X., Shen, G., Zhou, L., Li, Y., Wang, T., & Ma, X. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.851367 · Cited by 205
“Patients with a high suspicion of invasive cancer should undergo colposcopy-guided biopsy, the gold standard for the diagnosis of cervical cancer and plays a key role in the early detection of cervical cancer (26).”
BackgroundSelf-citationPassive daytime radiative cooling: Fundamentals, material designs, and applications
Chen, M., Pang, D., Chen, X., Yan, H., & Yang, Y. (2022) · EcoMat · doi:10.1002/eom2.12153 · Cited by 203
Magne, T. M., de Oliveira Vieira, T., Alencar, L. M. R., Junior, F. F. M., Gemini-Piperni, S., Carneiro, S. V., Fechine, L. M. U. D., Freire, R. M., Golokhvast, K., Metrangolo, P., et al. (2022) · Journal of Nanostructure in Chemistry · doi:10.1007/s40097-021-00444-3 · Cited by 197
Metadata
- Authors
- Yuan, C., Yao, Y., Cheng, B., Cheng, Y., Li, Y., Li, Y., Liu, X., Cheng, X., Xie, X., Wu, J., Wang, X., & Lu, W.
- Venue
- Scientific Reports
- Published
- 2020-07-15
- Volume
- 10
- Issue
- 1
- Pages
- 11639-11639
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3043279728
- Cited by
- 213
- References
- 38
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.