A deep learning model for identifying diabetic retinopathy using optical coherence tomography angiography
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
As the prevalence of diabetes increases, millions of people need to be screened for diabetic retinopathy (DR). Remarkable advances in technology have made it possible to use artificial intelligence to screen DR from retinal images with high accuracy and reliability, resulting in reducing human labor by processing large amounts of data in a shorter time. We developed a fully automated classification algorithm to diagnose DR and identify referable status using optical coherence tomography angiography (OCTA) images with convolutional neural network (CNN) model and verified its feasibility by comparing its performance with that of conventional machine learning model. Ground truths for classifications were made based on ultra-widefield fluorescein angiography to increase the accuracy of data annotation. The proposed CNN classifier achieved an accuracy of 91–98%, a sensitivity of 86–97%, a specificity of 94–99%, and an area under the curve of 0.919–0.976. In the external validation, overall similar performances were also achieved. The results were similar regardless of the size and depth of the OCTA images, indicating that DR could be satisfactorily classified even with images comprising narrow area of the macular region and a single image slab of retina. The CNN-based classification using OCTA is expected to create a novel diagnostic workflow for DR detection and referral.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697 · cited 1×
“In this study, a deep CNN algorithm using OCTA achieved comparable accuracy to previous CNN-based DR grading algorithms using fundus photographs with less than 250 samples 11–15 .”
MethodCheung, N., Mitchell, P., & Wong, T. Y. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62124-3 · Cited by 3,288
Antonetti, D. A., Klein, R., & Gardner, T. W. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1005073 · Cited by 1,659
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Randomized controlled trial of a 12-week digital care program in improving low back pain
Shebib, R., Bailey, J. F., Smittenaar, P., Perez, D. A., Mecklenburg, G., & Hunter, S. (2019) · npj Digital Medicine · doi:10.1038/s41746-018-0076-7 · Cited by 341
Ruamviboonsuk, P., Krause, J., Chotcomwongse, P., Sayres, R., Raman, R., Widner, K., Campana, B. J. L., Phene, S., Hemarat, K., Tadarati, M., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0099-8 · Cited by 233 · cited 1×
“In this study, a deep CNN algorithm using OCTA achieved comparable accuracy to previous CNN-based DR grading algorithms using fundus photographs with less than 250 samples 11–15 .”
MethodAutomated Diagnosis and Grading of Diabetic Retinopathy Using Optical Coherence Tomography
Sandhu, H. S., Eltanboly, A., Shalaby, A., Keynton, R. S., Schaal, S., & El-Baz, A. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-23677 · Cited by 44
Cited by
AI-Driven Clinical Decision Support Systems: An Ongoing Pursuit of Potential
Elhaddad, M., & Hamam, S. (2024) · Cureus · doi:10.7759/cureus.57728 · Cited by 301
“Ryu et al. developed a CNN model capable of predicting diabetic retinopathy from OCTA images with an accuracy of 91%-98%, underscoring AI’s potential in facilitating timely interventions to prevent irreversible damage and improve patient outcomes [17].”
BackgroundVision Transformers in medical computer vision—A contemplative retrospection
Parvaiz, A., Khalid, M. A., Zafar, R., Ameer, H., Ali, M., & Fraz, M. M. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.106126 · Cited by 276
Liu, X., Wu, J., Shao, A., Shen, W., Ye, P., Wang, Y., Ye, J., Jin, K., & Yang, J. (2024) · Journal of Medical Internet Research · doi:10.2196/51926 · Cited by 52
Artificial intelligence for early detection of diabetes mellitus complications via retinal imaging
Sobhi, N., Sadeghi-Bazargani, Y., Mirzaei, M., Abdollahi, M., Jafarizadeh, A., Pedrammehr, S., Alizadehsani, R., Tan, R.-S., Islam, S. M. S., & Acharya, U. R. (2025) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-025-01596-7 · Cited by 39
Elsharkawy, M., Elrazzaz, M., Sharafeldeen, A., Alhalabi, M., Khalifa, F., Soliman, A., Elnakib, A., Mahmoud, A., Ghazal, M., El-Daydamony, E., et al. (2022) · Sensors · doi:10.3390/s22093490 · Cited by 38
Metadata
- Authors
- Ryu, G., Lee, K., Park, D., Park, S. H., & Sagong, M.
- Venue
- Scientific Reports
- Published
- 2021-11-26
- Volume
- 11
- Issue
- 1
- Pages
- 23024-23024
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3215326316
- Cited by
- 87
- References
- 9
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A deep learning model for identifying diabetic retinopathy using optical coherence tomography angiography. https://app.cochat.ai/papers/10.1038/s41598-021-02479-6
- The paper
- Ryu, G., Lee, K., Park, D., Park, S. H., & Sagong, M. (2021). A deep learning model for identifying diabetic retinopathy using optical coherence tomography angiography. Scientific Reports. https://doi.org/10.1038/s41598-021-02479-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.