ECG-based machine-learning algorithms for heartbeat classification
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Electrocardiogram (ECG) signals represent the electrical activity of the human hearts and consist of several waveforms (P, QRS, and T). The duration and shape of each waveform and the distances between different peaks are used to diagnose heart diseases. In this work, to better analyze ECG signals, a new algorithm that exploits two-event related moving-averages (TERMA) and fractional-Fourier-transform (FrFT) algorithms is proposed. The TERMA algorithm specifies certain areas of interest to locate desired peak, while the FrFT rotates ECG signals in the time-frequency plane to manifest the locations of various peaks. The proposed algorithm’s performance outperforms state-of-the-art algorithms. Moreover, to automatically classify heart disease, estimated peaks, durations between different peaks, and other ECG signal features were used to train a machine-learning model. Most of the available studies uses the MIT-BIH database (only 48 patients). However, in this work, the recently reported Shaoxing People’s Hospital (SPH) database, which consists of more than 10,000 patients, was used to train the proposed machine-learning model, which is more realistic for classification. The cross-database training and testing with promising results is the uniqueness of our proposed machine-learning model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
The fractional Fourier transform and time-frequency representations
Almeida, L. B. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.330368 · Cited by 1,924
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Digital computation of the fractional Fourier transform
Ozaktas, H. M., Arikan, O., Kutay, M. A., & Bozdagt, G. (1996) · IEEE Transactions on Signal Processing · doi:10.1109/78.536672 · Cited by 1,187
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Dagenais, G. R., Leong, D. P., Rangarajan, S., Lanas, F., Lopez-Jaramillo, P., Gupta, R., Diaz, R., Avezum, A., Oliveira, G. B. F., Wielgosz, A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(19)32007-0 · Cited by 651
Martínez-Sancho, E., Slámová, L., Morganti, S., Grefen, C., Carvalho, B., Dauphin, B., Rellstab, C., Gugerli, F., Opgenoorth, L., Heer, K., et al. (2020) · Scientific Data · doi:10.1038/s41597-019-0340-y · Cited by 496
A 12-lead electrocardiogram database for arrhythmia research covering more than 10,000 patients
Zheng, J., Zhang, J., Danioko, S., Yao, H., Guo, H., & Rakovski, C. (2020) · Scientific Data · doi:10.1038/s41597-020-0386-x · Cited by 487 · cited 1×
“In this work, MIT-BIH arrhythmia 21 and SPH 34 database signals were used.”
MethodFractional Fourier transform as a signal processing tool: An overview of recent developments
Sejdić, E., Djurović, I., & Stanković, L. (2011) · Signal Processing · doi:10.1016/j.sigpro.2010.10.008 · Cited by 424 · cited 1×
“The FrFT of a signal can be defined as follows 26 : where α is the order of FrFT and φ = απ/ 2 is the angle of rotation.”
BackgroundSchneider, T., & Neumaier, A. (2001) · ACM Transactions on Mathematical Software · doi:10.1145/382043.382316 · Cited by 388 · cited 1×
“Moreover, auto-regressive (AR) model coefficients of the ECG signal can be used as a feature 33 .”
MethodSieberts, S. K., Perumal, T. M., Carrasquillo, M. M., Allen, M., Reddy, J. S., Hoffman, G. E., Dang, K. K., Calley, J., Ebert, P. J., Eddy, J., et al. (2020) · Scientific Data · doi:10.1038/s41597-020-00642-8 · Cited by 318
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Classification of ECG signals using machine learning techniques: A survey
Jambukia, S. H., Dabhi, V. K., & Prajapati, H. B. (2015) · 2015 International Conference on Advances in Computer Engineering and Applications · doi:10.1109/icacea.2015.7164783 · Cited by 248 · cited 1×
“This technique can immediately prioritize the patients that need urgent medical attention 35 .”
MethodECG Feature Extraction and Classification Using Wavelet Transform and Support Vector Machines
Zhao, Q., & Zhang, L. (2006) · 2005 International Conference on Neural Networks and Brain · doi:10.1109/icnnb.2005.1614807 · Cited by 239 · cited 4×
“The parameter values of C and γ = 12 σ 2 were respectively adjusted to 65536 and 2.44 × 10 − 4 37 .”
BackgroundMethodInfluentialXiong, Z., Stiles, M., & Zhao, J. (2017) · Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2017.066-138 · Cited by 171
Classification of imbalanced ECG beats using re-sampling techniques and AdaBoost ensemble classifier
Rajesh, K. N. V. P. S., & Dhuli, R. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.12.004 · Cited by 163
Alves, L. G. A., Ribeiro, H. V., Lenzi, E. K., & Mendes, R. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0069580 · Cited by 154
FREQUENCY BANDS EFFECTS ON QRS DETECTION
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0002742704280431 · Cited by 147 · cited 1×
“It was reported in 30 , that most of the QRS complex energy is concentrated within the range of 8 to 20 Hz.”
BackgroundNaïve Bayes Classifier for ECG Abnormalities Using Multivariate Maximal Time Series Motif
Padmavathi, S. V., & Ramanujam, E. (2015) · Procedia Computer Science · doi:10.1016/j.procs.2015.03.201 · Cited by 69
A Proof-of-Concept Study: Simple and Effective Detection of P and T Waves in Arrhythmic ECG Signals
Elgendi, M., Meo, M., & Abbott, D. (2016) · Bioengineering · doi:10.3390/bioengineering3040026 · Cited by 63
R wave detection using Coiflets wavelets
Elgendi, M., Jonkman, M., & Boer, F. D. (2009) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2009.4967756 · Cited by 47
2005 International Conference on Neural Networks and Brain
(2005) · International Conference on Neural Networks and Brain · doi:10.1109/icnnb.2005.1614852 · Cited by 30
TERMA Framework for Biomedical Signal Analysis: An Economic-Inspired Approach
Elgendi, M. (2016) · Biosensors · doi:10.3390/bios6040055 · Cited by 26
Mabrouki, R., Khaddoumi, B., & Sayadi, M. (2014) · International Conference on Advanced Technologies for Signal and Image Processing · doi:10.1109/atsip.2014.6834603 · Cited by 19
ECG baseline drift removal using discrete wavelet transform
Vega-Martínez, G., Alvarado-Serrano, C., & Leija, L. (2011) · International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE) · doi:10.1109/iceee.2011.6106625 · Cited by 15 · cited 1×
“The baseline drift is mostly localized around 0.5Hz 28 .”
BackgroundSingle Scale CWT Algorithm for ECG Beat Detection for a Portable Monitoring System
Smaoui, G., Young, A., & Abid, M. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0212-2 · Cited by 15
Aiding the Detection of QRS Complex in ECG Signals by Detecting S Peaks Independently
Sabherwal, P., Singh, L., & Agrawal, M. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-0355-0 · Cited by 11 · cited 1×
“…using different metrics reported in the literature, such as sensitivity, positive predictivity, and error-rate, which are defined as follows 39,40 : where TP denotes the true-positive, FN denotes the false-negative defined as the annotated peaks not detected by the algorithm, and FP…”
Fractional Fourier Transform Based QRS Complex Detection in ECG Signal
Yaqoob, T., Aziz, S., Ahmed, S., Amin, O., & Alouini, M. (2020) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp40776.2020.9052939 · Cited by 8 · cited 1×
“In R-peak detection, time localization is very important 32 .”
BackgroundSelf-citationMotion artifact suppression in the ECG signal by successive modifications in frequency and time
Subramaniam, S. R., Ling, B. W., & Georgakis, A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609527 · Cited by 7 · cited 11×
“First step is to remove the baseline drift using DWT 27 .”
MethodInfluentialECG parameter extraction and classification in noisy signals
Maciejewski, M., & Dzida, G. J. (2017) · Signal Processing: Algorithms, Architectures, Arrangements, and Applications · doi:10.23919/spa.2017.8166872 · Cited by 7
Cited by
Gala, D., Behl, H., Shah, M., & Makaryus, A. N. (2024) · Healthcare · doi:10.3390/healthcare12040481 · Cited by 183
“The algorithm outperformed existing methods and utilized the Shaoxing People’s Hospital (SPH) database, which included over 10,000 patients, making it a more realistic dataset for training a machine-learning model [46].”
Kaur, D., Hughes, J. W., Rogers, A. J., Kang, G., Narayan, S. M., Ashley, E. A., & Perez, M. V. (2024) · Circulation: Heart Failure · doi:10.1161/circheartfailure.123.010879 · Cited by 58
Metadata
- Authors
- Aziz, S., Ahmed, S., & Alouini, M.-S.
- Venue
- Scientific Reports
- Published
- 2021-09-21
- Volume
- 11
- Issue
- 1
- Pages
- 18738-18738
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3201016655
- Cited by
- 200
- References
- 31
- FWCI
- 17.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.