CoChat

Physical imaging parameter variation drives domain shift

Kilim, Oz, Olar, Alex, Joó, Tamás, Palicz, Tamás, Pollner, Péter, Csabai, István · 2022 · Scientific Reports
Cited by 39

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Statistical learning algorithms strongly rely on an oversimplified assumption for optimal performance, that is, source (training) and target (testing) data are independent and identically distributed. Variation in human tissue, physician labeling and physical imaging parameters (PIPs) in the generative process, yield medical image datasets with statistics that render this central assumption false. When deploying models, new examples are often out of distribution with respect to training data, thus, training robust dependable and predictive models is still a challenge in medical imaging with significant accuracy drops common for deployed models. This statistical variation between training and testing data is referred to as domain shift (DS).To the best of our knowledge we provide the first empirical evidence that variation in PIPs between test and train medical image datasets is a significant driver of DS and model generalization error is correlated with this variance. We show significant covariate shift occurs due to a selection bias in sampling from a small area of PIP space for both inter and intra-hospital regimes. In order to show this, we control for population shift, prevalence shift, data selection biases and annotation biases to investigate the sole effect of the physical generation process on model generalization for a proxy task of age group estimation on a combined 44 k image mammogram dataset collected from five hospitals.We hypothesize that training data should be sampled evenly from PIP space to produce the most robust models and hope this study provides motivation to retain medical image generation metadata that is almost always discarded or redacted in open source datasets. This metadata measured with standard international units can provide a universal regularizing anchor between distributions generated across the world for all current and future imaging modalities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-022-23990-4

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Research works printed but not linked: 31

  1. Malich, A., Fischer, D. R. & Böttcher, J. Cad for mammography: The technique, results, current role and further developments. Eur. Radiol. 16, 1449–1460 (2006). · DOI
  2. Puliti, D. et al. Overdiagnosis in mammographic screening for breast cancer in Europe: A literature review. J. Med. Screen. 19, 42–56 (2012). · DOI · Paper page
  3. Williams, M. B. et al. Optimization of exposure parameters in full field digital mammography. Med. Phys. 35, 2414–2423 (2008). · doi:10.1118/1.2912177
  4. Zhao, R. et al. Study on the inverse square law of X-ray radiation field. Chin. J. Nucl. Sci. Eng. 37, 482–486 (2017).
  5. Baur, M., Uhlmann, N., Pöschel, T. & Schröter, M. Correction of beam hardening in X-ray radiograms. Rev. Sci. Instrum. 90, 025108 (2019). · doi:10.1063/1.5080540
  6. Kouw, W. M. & Loog, M. An introduction to domain adaptation and transfer learning. arXiv preprint arXiv:1812.11806 (2018). · arXiv
  7. Zhang, Y., Liang, G., Jacobs, N. & Wang, X. Unsupervised domain adaptation for mammogram image classification: A promising tool for model generalization. arXiv preprint arXiv:2003.01111 (2020). · arXiv
  8. Zhu, J. -Y., Park, T., Isola, P. & Efros, A. A. Unpaired image-to-image translation using cycle-consistent adversarial networks. In Proceedings of the IEEE International Conference on Computer Vision, 2223–2232 (2017). · DOI · Paper page
  9. Zhang, L. et al. Generalizing deep learning for medical image segmentation to unseen domains via deep stacked transformation. IEEE Trans. Med. Imaging 39, 2531–2540 (2020). · DOI · Paper page
  10. Tirindelli, M. et al. Rethinking ultrasound augmentation: A physics-inspired approach. In International Conference on Medical Image Computing and Computer-Assisted Intervention 690–700 (Springer, 2021).
  11. Desai, A. D. et al. Vortex: Physics-driven data augmentations for consistency training for robust accelerated mri reconstruction. arXiv preprint arXiv:2111.02549 (2021). · arXiv
  12. Ganin, Y. et al. Domain-adversarial training of neural networks. J. Mach. Learn. Res. 17, 2096–2030 (2016).
  13. Kamnitsas, K. et al. Unsupervised domain adaptation in brain lesion segmentation with adversarial networks. In International Conference on Information Processing in Medical Imaging 597–609 (Springer, 2017). · DOI · Paper page
  14. Kouw, W. M., Loog, M., Bartels, L. W. & Mendrik, A. M. Mr acquisition-invariant representation learning. arXiv preprint arXiv:1709.07944 (2017). · arXiv
  15. Liu, Q., Chen, C., Qin, J., Dou, Q. & Heng, P. -A. Feddg: Federated domain generalization on medical image segmentation via episodic learning in continuous frequency space. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 1013–1023 (2021). · DOI · Paper page
  16. Cai, H. et al. Breast microcalcification diagnosis using deep convolutional neural network from digital mammograms. Comput. Math. Methods Med. 2019 (2019). · DOI
  17. Wang, J. et al. Discrimination of breast cancer with microcalcifications on mammography by deep learning. Sci. Rep. 6, 1–9 (2016). · DOI · Paper page
  18. Mustra, M., Delac, K. & Grgic, M. Overview of the dicom standard. In 2008 50th International Symposium ELMAR, Vol. 1, 39–44 (IEEE, 2008).
  19. Etta, D., Pisano, S. Z., Zong, R. & Jhonston, E. Contrast limited adaptive histogram equalization image processing to improve the detection of simulated speculation in dense monograms. J. Digit. Imaging 11, 193–200 (1998). · DOI · Paper page
  20. Krizhevsky, A., Sutskever, I. & Hinton, G. E. Imagenet classification with deep convolutional neural networks. Adv. Neural Inf. Process. Syst. 25 (2012).
  21. Paszke, A. et al. Pytorch: An imperative style, high-performance deep learning library. Adv. Neural Inf. Process. Syst. 32 (2019).
  22. Schafft, K. A. & Kulcsár, L. J. The demography of race and ethnicity in hungary. In The International Handbook of the Demography of Race and Ethnicity, 553–573 (Springer, 2015). · doi:10.1007/978-90-481-8891-8_26
  23. Yu, A. C. & Eng, J. One algorithm may not fit all: How selection bias affects machine learning performance. Radiographics 40, 1932–1937 (2020). · DOI · Paper page
  24. Boncz, I. et al. The organisation and results of first screening round of the hungarian nationwide organised breast cancer screening programme. Ann. Oncol. 18, 795–799 (2007). · doi:10.1093/annonc/mdl489
  25. Checka, C. M., Chun, J. E., Schnabel, F. R., Lee, J. & Toth, H. The relationship of mammographic density and age: Implications for breast cancer screening. Am. J. Roentgenol. 198, W292–W295 (2012). · DOI · Paper page
  26. Lekamlage, C. D., Afzal, F., Westerberg, E. & Cheddad, A. Mini-ddsm: Mammography-based automatic age estimation. In 2020 3rd International Conference on Digital Medicine and Image Processing, 1–6 (2020). · DOI
  27. Kwan, R. K. -S., Evans, A. C. & Pike, G. B. An extensible mri simulator for post-processing evaluation. In International Conference on Visualization in Biomedical Computing, 135–140 (Springer, 1996). · DOI · Paper page
  28. Opieliński, K. J. et al. Multimodal ultrasound computer-assisted tomography: An approach to the recognition of breast lesions. Comput. Med. Imaging Graph. 65, 102–114 (2018). · doi:10.1016/j.compmedimag.2017.06.009
  29. Goodfellow, I. J., Shlens, J. & Szegedy, C. Explaining and harnessing adversarial examples. arXiv preprint arXiv:1412.6572 (2014). · arXiv
  30. Yang, H. et al. Unpaired brain mr-to-ct synthesis using a structure-constrained cyclegan. In Deep Learning in Medical Image Analysis and Multimodal Learning for Clinical Decision Support, 174–182 (Springer, 2018). · DOI · Paper page
  31. Ghandeharioun, A. et al. Dissect: Disentangled simultaneous explanations via concept traversals. ArXiv:2105.15164 (2021). · arXiv

Metadata

Authors
Kilim, O., Olar, A., Joó, T., Palicz, T., Pollner, P., & Csabai, I.
Venue
Scientific Reports
Published
2022-12-09
Volume
12
Issue
1
ISSN
2045-2322
Cited by
39
References
11
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physical imaging parameter variation drives domain shift. https://app.cochat.ai/papers/10.1038/s41598-022-23990-4
The paper
Kilim, O., Olar, A., Joó, T., Palicz, T., Pollner, P., & Csabai, I. (2022). Physical imaging parameter variation drives domain shift. Scientific Reports. https://doi.org/10.1038/s41598-022-23990-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.