Unpaired Brain MR-to-CT Synthesis Using a Structure-Constrained CycleGAN
Open accessAbstract
The cycleGAN is becoming an influential method in medical image synthesis. However, due to a lack of direct constraints between input and synthetic images, the cycleGAN cannot guarantee structural consistency between these two images, and such consistency is of extreme importance in medical imaging. To overcome this, we propose a structure-constrained cycleGAN for brain MR-to-CT synthesis using unpaired data that defines an extra structure-consistency loss based on the modality independent neighborhood descriptor to constrain structural consistency. Additionally, we use a position-based selection strategy for selecting training images instead of a completely random selection scheme. Experimental results on synthesizing CT images from brain MR images demonstrate that our method is better than the conventional cycleGAN and approximates the cycleGAN trained with paired data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unpaired image-to-image translation using cycle-consistent adversarial networks
Zhu, J.-Y., Park, T., Isola, P., & Efros, A. A. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.244 · Cited by 23,602
Cited by
Generative adversarial network in medical imaging: A review
Yi, X., Walia, E., & Babyn, P. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101552 · Cited by 1,863
ResViT: Residual Vision Transformers for Multimodal Medical Image Synthesis
Dalmaz, O., Yurt, M., & Cukur, T. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3167808 · Cited by 597
Unsupervised Medical Image Translation With Adversarial Diffusion Models
Özbey, M., Dalmaz, O., Dar, S. U. H., Bedel, H. A., Özturk, Ş., Güngör, A., & Çukur, T. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3290149 · Cited by 517
Unsupervised MR-to-CT Synthesis Using Structure-Constrained CycleGAN
Yang, H., Sun, J., Carass, A., Zhao, C., Lee, J., Prince, J. L., & Xu, Z. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3015379 · Cited by 204
Self-citationDeep learning for Alzheimer's disease diagnosis: A survey
Khojaste-Sarakhsi, M., Haghighi, S. S., Ghomi, S. M. T. F., & Marchiori, E. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102332 · Cited by 194
Metadata
- Authors
- Yang, H., Sun, J., Carass, A., Zhao, C., Lee, J., Xu, Z., & Prince, J.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2018
- Pages
- 174-182
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2889779108
- Cited by
- 180
- References
- 1
- FWCI
- 4.46
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unpaired Brain MR-to-CT Synthesis Using a Structure-Constrained CycleGAN. https://app.cochat.ai/papers/10.1007/978-3-030-00889-5_20
- The paper
- Yang, H., Sun, J., Carass, A., Zhao, C., Lee, J., Xu, Z., & Prince, J. (2018). Unpaired Brain MR-to-CT Synthesis Using a Structure-Constrained CycleGAN. Lecture Notes in Computer Science. https://doi.org/10.1007/978-3-030-00889-5_20
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.