CoChat

A quantitative meta-analysis comparing cell models in perfused organ on a chip with static cell cultures

Open access
Dufva, Martin · 2023 · Scientific Reports

Published version of a preprint

The DOI matches its Crossref record; 173 of the 174 references it cites were found in a registry or an index.

Abstract

As many consider organ on a chip for better in vitro models, it is timely to extract quantitative data from the literature to compare responses of cells under flow in chips to corresponding static incubations. Of 2828 screened articles, 464 articles described flow for cell culture and 146 contained correct controls and quantified data. Analysis of 1718 ratios between biomarkers measured in cells under flow and static cultures showed that the in all cell types, many biomarkers were unregulated by flow and only some specific biomarkers responded strongly to flow. Biomarkers in cells from the blood vessels walls, the intestine, tumours, pancreatic island, and the liver reacted most strongly to flow. Only 26 biomarkers were analysed in at least two different articles for a given cell type. Of these, the CYP3A4 activity in CaCo2 cells and PXR mRNA levels in hepatocytes were induced more than two-fold by flow. Furthermore, the reproducibility between articles was low as 52 of 95 articles did not show the same response to flow for a given biomarker. Flow showed overall very little improvements in 2D cultures but a slight improvement in 3D cultures suggesting that high density cell culture may benefit from flow. In conclusion, the gains of perfusion are relatively modest, larger gains are linked to specific biomarkers in certain cell types.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-023-35043-5

Cites

173 of 173 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Overview of different cell culture methods. The green tick marks indicate which conditions that were included in the meta-analysis. Chips can be operated in many ways. The medium passes the cells only once in perfused chips. Alternatively, the medium is recirculated using either one directional or two directional flows. Recirculation is a form of batch culture with, normally, a larger medium to cell ratio than to wells and flasks. The traditional culture box indicates configurations to obtain similar functionalities as in the corresponding chips. Many of the plate/well controls could be agitated to provide better mass transfer (mixing) or shear but these controls were not generally used in the literature.
Figure 1 Overview of different cell culture methods. The green tick marks indicate which conditions that were included in the meta-analysis. Chips can be operated in many ways. The medium passes the cells only once in perfused chips. Alternatively, the medium is recirculated using either one directional or two directional flows. Recirculation is a form of batch culture with, normally, a larger medium to cell ratio than to wells and flasks. The traditional culture box indicates configurations to obtain similar functionalities as in the corresponding chips. Many of the plate/well controls could be agitated to provide better mass transfer (mixing) or shear but these controls were not generally used in the literature.CC BY · PubMed Central
Figure 2 Summary of the study. (A) flow diagram of the selection of articles. (B) The number of scientific articles screened and selected. (C) The number of articles using the respective tissue. (D) The number of data points where the significance was tested and on which level. “NS”—tested but no significance “No stat”—no statistical test was performed. (E) The number of biomarker ratios per tissue that could be calculated from the data in the literature.
Figure 2 Summary of the study. (A) flow diagram of the selection of articles. (B) The number of scientific articles screened and selected. (C) The number of articles using the respective tissue. (D) The number of data points where the significance was tested and on which level. “NS”—tested but no significance “No stat”—no statistical test was performed. (E) The number of biomarker ratios per tissue that could be calculated from the data in the literature.CC BY · PubMed Central
Figure 3 (A) Scatter plot of raw extracted data from well static controls and chips under perfusion or recirculation (Dynamic cultures). The axes show log2 transformed data. (B) Corresponding boxplot of the data in (A). (C) Scatter plot of raw extracted data from chip static controls and perfused chips. (D) Corresponding boxplot of the data in (C). The median biomarker ratio value per tissue for the wells (E) and chip static controls (F) respectively on a linear scale. “All” means all data and “> 0.7” means raw data that forms a ratio above 0.7 when biomarker activity obtained in a chip under flow is divided with the respective static control. *P < 0.05, **P < 0.01, ***P < 0.001 using t-test on raw data on from dynamic and static culture respectively.
Figure 3 (A) Scatter plot of raw extracted data from well static controls and chips under perfusion or recirculation (Dynamic cultures). The axes show log2 transformed data. (B) Corresponding boxplot of the data in (A). (C) Scatter plot of raw extracted data from chip static controls and perfused chips. (D) Corresponding boxplot of the data in (C). The median biomarker ratio value per tissue for the wells (E) and chip static controls (F) respectively on a linear scale. “All” means all data and “> 0.7” means raw data that forms a ratio above 0.7 when biomarker activity obtained in a chip under flow is divided with the respective static control. *P < 0.05, **P < 0.01, ***P < 0.001 using t-test on raw data on from dynamic and static culture respectively.CC BY · PubMed Central
Figure 4 Boxplots of biomarker regulation (log2 ratio) in different tissues by flow. Blue shows the data with wells as static controls and yellow shows data with chips as static controls. “n” indicates the number of observations for wells as static controls and “m” indicated the number of observations for chips as static control for the respective biomarker. “n” and “m” are also reported in Fig. 2E that gives a better overview. Lightly grey shaded area around 0 indicate two-fold up and down regulation respectively (log2(2) = 1 and log2(0.5) = − 1). Darker grey shaded area around of indicate 0.7–1.4-fold regulation (log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5) respectively.
Figure 4 Boxplots of biomarker regulation (log2 ratio) in different tissues by flow. Blue shows the data with wells as static controls and yellow shows data with chips as static controls. “n” indicates the number of observations for wells as static controls and “m” indicated the number of observations for chips as static control for the respective biomarker. “n” and “m” are also reported in Fig. 2E that gives a better overview. Lightly grey shaded area around 0 indicate two-fold up and down regulation respectively (log2(2) = 1 and log2(0.5) = − 1). Darker grey shaded area around of indicate 0.7–1.4-fold regulation (log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5) respectively.CC BY · PubMed Central
Figure 5 Analysis of biomarker distributions of Log2(ratio) data. (A) Histograms showing the distribution of ratio for biomarkers. “All” includes all the biomarker data from wells (blue) and chips (yellow) as static control, respectively. “No mRNA” is all the biomarkers but excluding the mRNA data. “mRNA” only includes mRNA data. (B) The number of observations within a given ratio interval on the linear scale. Strong blue includes all ratios, medium blue includes ratio interval log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5 and light blue includes the ratio interval log2(0.5) = − 1 to log2(2) = 1. (C) Calculated skewness and kurtosis on the respective distributions for wells as control using the respective data subset described in (A). (D) The number of observations in each ratio interval for chip control. See (B) for interval explanations. (E) Calculated skewness and kurtosis on the respective distributions for chips as controls.
Figure 5 Analysis of biomarker distributions of Log2(ratio) data. (A) Histograms showing the distribution of ratio for biomarkers. “All” includes all the biomarker data from wells (blue) and chips (yellow) as static control, respectively. “No mRNA” is all the biomarkers but excluding the mRNA data. “mRNA” only includes mRNA data. (B) The number of observations within a given ratio interval on the linear scale. Strong blue includes all ratios, medium blue includes ratio interval log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5 and light blue includes the ratio interval log2(0.5) = − 1 to log2(2) = 1. (C) Calculated skewness and kurtosis on the respective distributions for wells as control using the respective data subset described in (A). (D) The number of observations in each ratio interval for chip control. See (B) for interval explanations. (E) Calculated skewness and kurtosis on the respective distributions for chips as controls.CC BY · PubMed Central
Figure 6 Regulation of biomarker classes by flow. The data is log2 transformed. Blue shows wells as static controls and yellow shows chips as static controls. “Cell physiology” include a collection of higher-level cell functions not covered by the other functions in the figure. “n” indicates the number of observations for wells as static controls and “m” indicated the number of observations for chips as static control for the respective biomarker. Lightly grey shaded area around 0 indicate two-fold up and down regulation respectively (log2(2) = 1 and log2(0.5) = − 1). Darker grey shaded area around of indicate 0.7–1.4-fold regulation (log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5) respectively.
Figure 6 Regulation of biomarker classes by flow. The data is log2 transformed. Blue shows wells as static controls and yellow shows chips as static controls. “Cell physiology” include a collection of higher-level cell functions not covered by the other functions in the figure. “n” indicates the number of observations for wells as static controls and “m” indicated the number of observations for chips as static control for the respective biomarker. Lightly grey shaded area around 0 indicate two-fold up and down regulation respectively (log2(2) = 1 and log2(0.5) = − 1). Darker grey shaded area around of indicate 0.7–1.4-fold regulation (log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5) respectively.CC BY · PubMed Central
Figure 7 Log2 ratio boxplots for each specific biomarker and cell type. The data from chips and wells as controls were pooled for the respective biomarker. “m” indicates the number of publications and “n” indicates the total number of observations in the publications for the respective biomarker. Lightly grey shaded area around 0 indicate two-fold up and down regulation respectively (log2(2) = 1 and log2(0.5) = − 1). Darker grey shaded area around of indicate 0.7–1.4-fold regulation (log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5). The specific biomarkers were categorised into three classes based on the deviation from two-fold regulations (stringent) or being above 0 (less stringent). If a biomarker had observations both inside and outside the light grey area, they were classified as inconsistently regulated.
Figure 7 Log2 ratio boxplots for each specific biomarker and cell type. The data from chips and wells as controls were pooled for the respective biomarker. “m” indicates the number of publications and “n” indicates the total number of observations in the publications for the respective biomarker. Lightly grey shaded area around 0 indicate two-fold up and down regulation respectively (log2(2) = 1 and log2(0.5) = − 1). Darker grey shaded area around of indicate 0.7–1.4-fold regulation (log2(~ 0.7) = − 0.5 to log2(~ 1.4) = 0.5). The specific biomarkers were categorised into three classes based on the deviation from two-fold regulations (stringent) or being above 0 (less stringent). If a biomarker had observations both inside and outside the light grey area, they were classified as inconsistently regulated.CC BY · PubMed Central
Figure 8 Box plots of ratio of different cell classes under perfusion where the medium passes the chips once with wells as control (A), is recirculated on chip with wells as control (B) or perfused using a chip as control (C). (D) Comparison of perfusion, recirculation on 2D and 3D cultures respectively using wells as controls.
Figure 8 Box plots of ratio of different cell classes under perfusion where the medium passes the chips once with wells as control (A), is recirculated on chip with wells as control (B) or perfused using a chip as control (C). (D) Comparison of perfusion, recirculation on 2D and 3D cultures respectively using wells as controls.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 173 references

Research works printed but not linked: 6

  1. Levesque M Nerem R The elongation and origenation of cultured endothelial cell sin response to shear stress J. Biol. Eng. 1985 107 341 347 4079361
  2. Chen, Z., He, S., Zilberberg, J. & Lee, W. Pumpless platform for high-throughput dynamic multicellular culture and chemosensitivity evaluation. in Transactions of the Annual Meeting of the Society for Biomaterials and the Annual International Biomaterials Symposium vol. 40 705 (Society for Biomaterials, 2019). PMC6333476 30547180
  3. Miller PG Shuler ML Design and demonstration of a pumpless 14 compartment microphysiological system Biotechnol. Bioeng. 2016 113 2213 2227 10.1002/bit.25989 27070809 · DOI · Paper page
  4. Lee DW Choi N Sung JH A microfluidic chip with gravity-induced unidirectional flow for perfusion cell culture Biotechnol. Prog. 2019 35 e2701 10.1002/btpr.2701 30294886 · DOI · Paper page
  5. Lohasz, C., Frey, O., Bonanini, F., Renggli, K. & Hierlemann, A. Tubing-free microfluidic microtissue culture system featuring gradual, in vivo-like substance exposure profiles. Front. Bioeng. Biotechnol. 72 (2019). PMC6454105 31001529 · DOI
  6. Zhou, Q. et al. Lab on a Chip Liver injury-on-a-chip: Microfluidic co-cultures with integrated biosensors for monitoring liver cell signaling during injury. 15, (2014). 26480303 · DOI · Paper page

Cited by

Metadata

Authors
Dufva, M.
Affiliations
Technical University of Denmark (DK)
Corresponding author
Dufva, Martin
Venue
Scientific Reports
Published
2023-05-22
Volume
13
Issue
1
Pages
8233-8233
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4377292710
Cited by
14
References
174
Citations by year
2026: 7 · 2025: 5 · 2024: 1 · 2023: 1
FWCI
0.31
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Research Square (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion, other-oa)
Funders
H2020 Industrial Leadership (953201)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
organ-on-a-chip, perfusion, CYP3A4 induction, hepatocytes, Caco-2 cells, vascular cells, intestinal cells, pancreatic islets, reproducibility, 3D cell culture, in vitro model
MeSH terms
Microphysiological Systems, Humans, Reproducibility of Results, Biomarkers, Cell Culture Techniques, Caco-2 Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.