Cited by 40Radioactive element chemistry and processingChemical Synthesis and CharacterizationAdsorption and biosorption for pollutant removal

Ultra-effective modified clinoptilolite adsorbent for selective thorium removal from radioactive residue

Open access
Alotaibi, Abdulrahman Masoud, Ismail, Aznan Fazli, Aziman, Eli Syafiqah·2023·Scientific Reports

Abstract

This study investigated the efficacy of using phosphate-modified zeolite (PZ) as an adsorbent for removing thorium from aqueous solutions. The effects of various factors such as contact time, adsorbent mass, initial thorium concentration, and pH value of the solution on the removal efficiency were analyzed using the batch technique to obtain optimum adsorption condition. The results revealed that the optimal conditions for thorium adsorption were a contact time of 24 h, 0.03 g of PZ adsorbent, pH 3, and a temperature of 25 °C. Isotherm and kinetics parameters of the thorium adsorption on PZ were also determined, with equilibrium studies showing that the experimental data followed the Langmuir isotherm model. The maximum adsorption capacity (Q o) for thorium was found to be 17.3 mg/g with the Langmuir isotherm coefficient of 0.09 L/mg. Using phosphate anions to modify natural zeolite increased its adsorption capacity. Furthermore, adsorption kinetics studies demonstrated that the adsorption of thorium onto PZ adsorbent fitted well with the pseudo-second-order model. The applicability of the PZ adsorbent in removing thorium from real radioactive waste was also investigated, and nearly complete thorium removal was achieved (> 99%) from the leached solution obtained from cracking and leaching processes of rare earth industrial residue under optimized conditions. This study elucidates the potential of PZ adsorbent for efficient removal of thorium from rare earth residue via adsorption, leading to a reduction in waste volume for ultimate disposition.

Integrity signals

Registry

Crossref · 10.1038/s41598-023-36487-5

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Alotaibi, A. M., Ismail, A. F., & Aziman, E. S.
Affiliations
  • Umm al-Qura University (SA)
  • National University of Malaysia (MY)
Corresponding author
Ismail, Aznan Fazli
Venue
Scientific Reports
Published
2023-06-08
Volume
13
Issue
1
Pages
9316-9316
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4379966563
Cited by
40
References
3
Citations by year
2026: 14 · 2025: 10 · 2024: 12 · 2023: 4
FWCI
3.10
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Ministry of Higher Education (MoHE) Malaysia (FRGS/1/2020/STG07/UKM/02/5)
  • Universiti Kebangsaan Malaysia (DIP-2020-022)
Topics
  • Physical Sciences › Chemistry › Inorganic Chemistry › Radioactive element chemistry and processing
  • Physical Sciences › Environmental Science › Waste Management and Disposal › Chemical Synthesis and Characterization
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
Keywords
thorium removal, clinoptilolite, adsorption, radioactive waste, leaching solution, Langmuir isotherm, pseudo-second-order kinetics, pH effect, adsorption capacity, waste volume reduction
MeSH terms
Adsorption, Hydrogen-Ion Concentration, Kinetics, Phosphates, Temperature, Thermodynamics, Thorium, Water Pollutants, Chemical, Zeolites

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review