The DOI matches its Crossref record.
Asbestos Exposure During Renovation and Demolition of Asbestos-Cement Clad Buildings
Abstract
External asbestos cement (AC) claddings become weathered after many years by the gradual loss of cement from exposed surfaces; as a result, loosely bound layers enriched with asbestos fibers are formed. This effect usually appears pronounced with roof cladding but slight with wall cladding. Asbestos fibers on such weathered surfaces may be mixtures of chrysotile with amosite or crocidolite. Renovation and demolition of old AC clad buildings could cause asbestos fiber emission, but this has not been investigated in the past. The exposure of workers to asbestos dust during these operations and precautions to minimize exposure now have been investigated at several building sites. Asbestos dust concentrations during water jet cleaning or painting of weathered AC roofing were approximately 0.1 to 0.2 fibers per milliliter (f/ml.). Limited results suggest that concentrations may be reduced substantially by avoiding abrasion of surfaces. Concentrations during AC roof replacement averaged approximately 0.1 f/mL and were reduced markedly by employing more careful work procedures (e.g., by careful handling of sheets or by wet stacking of sheets). Asbestos dust concentrations during demolition by removal of whole sheets averaged 0.3 to 0.6 f/mL for roofs and less than 0.1 f/mL for walls, reflecting the significant differences in extent of weathering between these elements. Suppression of asbestos emissions from roof sheets by wetting or sealing of weathered surfaces was not predictable because of the occurrence of asbestos fibers in dust trapped under sheet laps. Precautions such as respiratory protection and clothing decontamination are considered to be essential for the demolition of roofing containing amosite or crocidolite by the procedures investigated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the literature on the subject proves that even a small scope of work can cause a high concentration of asbestos aerosol.28–30,34,35”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [30]
In the citing paper
“In the case of disassembly works with asbestos-cement products, concentrations of 0.1–0.6 f/ml were recorded, while in the case of incorrect removal of asbestos products using “spray on”, up to 100 f/ml were observed.”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [30]
In the citing paper
“Research leads to conclusions30,33 that exposure to historically high airborne fibre levels, prevailing half a century ago, may still occur today when special work procedures are not strictly applied.”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [30]
In the citing paper
“Weathering of ACMs has been well documented and may lead to higher asbestos fibre concentrations during asbestos abatement (Brown 1987; Spurny 1989; Obmiński 2020; Ervik et al. 2021).”
From Measurements of airborne asbestos fibres during refurbishing (2023) · cites this paper as Brown 1987
In the citing paper
“ACM roof sheet replacement was on average 0.1 f/cm3 over the full work operation.”
From Measurements of airborne asbestos fibres during refurbishing (2023) · cites this paper as Brown 1987
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
On the release of asbestos fibers from weathered and corroded asbestos cement products
Spurny, K. R. (1989) · Environmental Research · doi:10.1016/s0013-9351(89)80089-1 · Cited by 49
Asbestos in building and its destruction
Obmiński, A. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.118685 · Cited by 28
Stevulova, N., Estokova, A., Holub, M., Singovszka, E., & Csach, K. (2020) · Applied Sciences · doi:10.3390/app10114048 · Cited by 22
Measurements of airborne asbestos fibres during refurbishing
Ervik, T. K., Hammer, S. E., Skaugset, N. P., & Graff, P. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxad041 · Cited by 14
(2007) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mem020 · Cited by 9
Metadata
- Authors
- BROWN, S. K.
- Affiliations
- Commonwealth Scientific and Industrial Research Organisation (AU)
- Corresponding author
- BROWN, STEPHEN K.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1987-05
- Volume
- 48
- Issue
- 5
- Pages
- 478-486
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2150835037
- Cited by
- 49
- References
- 0
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 5 · 2022: 5 · 2021: 3 · 2020: 4 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 1 · 2013: 2 · 2012: 1
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Social Sciences › Health › Occupational Health and Global Justice
- Keywords
- asbestos exposure, building renovation, building demolition, chrysotile, amosite, crocidolite, water jet cleaning, roof replacement, respiratory protection, occupational exposure
- MeSH terms
- Asbestos, Construction Materials, Humans, Occupational Diseases
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Asbestos Exposure During Renovation and Demolition of Asbestos-Cement Clad Buildings. https://app.cochat.ai/papers/10.1080/15298668791385075
- The paper
- BROWN, S. K. (1987). Asbestos Exposure During Renovation and Demolition of Asbestos-Cement Clad Buildings. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298668791385075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.