CoChat

Development of low-cost pressure mapping device to evaluate force distribution for seat cushion modification

Jarumethitanont, Wimonrat, Manupibul, Udomporn, Tanthuwapathom, Ratikanlaya, Prasertsukdee, Saipin, Limroongreungrat, Weerawat, Charoensuk, Warakorn · 2024 · Scientific Reports
Cited by 8

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This study aimed to determine the reliability and concurrent validity of a low-cost pressure mapping system (Smart mat) and reference standard pressure mapping (MatScan). Thirty healthy volunteers aged 29.57 ± 4.50 years who could sit still for at least one minute and had a hip width of less than 40 cm (36 ± 2.05 cm) were recruited. The participants sat on the Smart mat system and MatScan for 60 s per trial for 3 trials. The reliability of Smart mat using intraclass correlation coefficients (ICC) showed an excellent ICC of normalised total force (nTF) and normalised ischial width (nIW) in sitting (0.93, 0.98). The validity was assessed using Spearman correlation coefficients, which showed that nTF in sitting had a significantly strong correlation (r = 0.70 ** ) and nIW in sitting had a significantly moderate correlation (r = 0.67 ** ). This study’s satisfactory results indicated that a low-cost pressure mapping system could be used for assessing forced distribution and ischial width during sitting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-024-72471-3

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 27

  1. O’Reilly, R. C., Morlet, T. & Cushing, S. L. Manual of Pediatric Balance Disorders (Plural Pub, 2013).
  2. Callegari, B. et al. Anticipatory postural adjustments and kinematic arm features when postural stability is manipulated. PeerJ 6, e4309. https://doi.org/10.7717/peerj.4309 (2018). · DOI
  3. Pedersen, L. K. et al. Postural seated balance in children can be assessed with good reliability. Gait Post. 47, 68–73. https://doi.org/10.1016/j.gaitpost.2016.04.007 (2016). · DOI
  4. Lanzetta, D., Cattaneo, D., Pellegatta, D. & Cardini, R. Trunk control in unstable sitting posture during functional activities in healthy subjects and patients with multiple sclerosis. Arch. Phys. Med. Rehabil. 85, 279–283. https://doi.org/10.1016/j.apmr.2003.05.004 (2004). · DOI
  5. Shen, W., Parenteau, C., Roychoudhury, R. & Robbins, J. Seated weight distribution of adults and children in normal and non-normal positions. Annu. Proc. Assoc. Advance. Autom. Med. 43, 383–397 (1999).
  6. Brogren, E., Hadders-Algra, M. & Forssberg, H. Postural control in sitting children with cerebral palsy. Neurosci. Biobehav. Rev. 22, 591–596. https://doi.org/10.1016/s0149-7634(97)00049-3 (1998). · DOI · Paper page
  7. Wininger, M. & Crane, B. A. Assessment of the minimally sufficient spatial sampling in pressure mapping the wheelchair seating interface. Technol. Disabil. 27, 119–125. https://doi.org/10.3233/TAD-150434 (2015). · DOI
  8. Wininger, M. & Crane, B. A. Prevalence of sensor saturation in wheelchair seat interface pressure mapping. Assist. Technol. 27, 69–75. https://doi.org/10.1080/10400435.2014.976800 (2015). · doi:10.1080/10400435.2014.976800
  9. Li, W. et al. The effects of the seat cushion contour and the sitting posture on surface pressure distribution and comfort during seated work. Int. J. Occup. Med. Environ. Health 33, 675–689. https://doi.org/10.13075/ijomeh.1896.01582 (2020). · doi:10.13075/ijomeh.1896.01582
  10. Fradet, L. et al. The use of pressure mapping for seating posture characterisation in children with cerebral palsy. Disabil. Rehabil. Assist Technol. 6, 47–56. https://doi.org/10.3109/17483107.2010.512969 (2011). · doi:10.3109/17483107.2010.512969
  11. Reguera-Garcia, M. M., Leiros-Rodriguez, R., Alvarez-Barrio, L. & Alonso-Cortes Fradejas, B. Analysis of postural control in sitting by pressure mapping in patients with multiple sclerosis, spinal cord injury and friedreich’s ataxia: A case series study. Sens. Basel 2020, 20. https://doi.org/10.3390/s20226488 (2020). · doi:10.3390/s20226488
  12. Taule, T. et al. Factors influencing optimal seating pressure after spinal cord injury. Spinal Cord 51, 273–277. https://doi.org/10.1038/sc.2012.163 (2013). · doi:10.1038/sc.2012.163
  13. Swanson, E. C., Weathersby, E. J., Cagle, J. C. & Sanders, J. E. Evaluation of force sensing resistors for the measurement of interface pressures in lower limb prosthetics. J. Biomech. Eng. 141, 1010091–10100913. https://doi.org/10.1115/1.4043561 (2019). · DOI
  14. Sadun, A. S., Jalani, J. & Sukor, J. A. In First International Workshop on Pattern Recognition (Xudong, J. et al. eds.) 1001112 (Springer, 2022).
  15. Giovanelli, D. & Farella, E. Force sensing resistor and evaluation of technology for wearable body pressure sensing. J. Sens. 2016, 9391850. https://doi.org/10.1155/2016/9391850 (2016). · DOI · Paper page
  16. Lee, B. W. & Shin, H. Feasibility study of sitting posture monitoring based on piezoresistive conductive film-based flexible force sensor. IEEE Sens. J. 16, 15–16. https://doi.org/10.1109/JSEN.2015.2480600 (2016). · DOI
  17. Schober, P., Boer, C. & Schwarte, L. A. Correlation coefficients: Appropriate use and interpretation. Anesthes. Analges. 126, 1763–1768. https://doi.org/10.1213/ane.0000000000002864 (2018). · DOI · Paper page
  18. Rosner, B. Fundamentals of Biostatistics, chapter 2 39 (Cengage Learning, 2015).
  19. Stinson, M. D., Porter-Armstrong, A. P. & Eakin, P. A. Pressure mapping systems: Reliability of pressure map interpretation. Clin. Rehabil. 17, 504–511. https://doi.org/10.1191/0269215503cr643oa (2003). · doi:10.1191/0269215503cr643oa
  20. Chen, Y.-L. Predicting external ischial tuberosity width for both sexes to determine their bicycle-seat sizes. Int. J. Ind. Ergon. 64, 118–121. https://doi.org/10.1016/j.ergon.2018.01.008 (2018). · doi:10.1016/j.ergon.2018.01.008
  21. Chen, Y. L. & Yang, P. J. A preliminary study of the measurement of external ischial tuberosity width and its gender differences. J. Phys. Therapy Sci. 28(3), 820–823 (2016). · doi:10.1589/jpts.28.820
  22. Sonenblum, S. E., Sprigle, S. H., Cathcart, J. M. & Winder, R. J. 3-dimensional buttocks response to sitting: A case report. J. Tissue Viabil. 22, 12–18. https://doi.org/10.1016/j.jtv.2012.11.001 (2013). · DOI
  23. Makhsous, M. et al. Use of MRI images to measure tissue thickness over the ischial tuberosity at different hip flexion. Clin. Anatomy 24, 638–645. https://doi.org/10.1002/ca.21119 (2011). · doi:10.1002/ca.21119
  24. Lana, M. R. V., Silva, P. C. S. & Barbosa, M. P. Analysis of the influence of an articulated seat position for wheelchair on the pressure distribution in the gluteal region. Rev. Bra. Eng. Bioméd. 30, 114–126. https://doi.org/10.1590/rbeb.2014.018 (2014). · DOI
  25. Kim, T.-H., Kwon, S.-J., Choi, H.-M. & Hong, Y.-S. Determination of lying posture through recognition of multitier body parts. Wirel. Commun. Mobile Comput. 2019, 9568584. https://doi.org/10.1155/2019/9568584 (2019). · DOI
  26. Stinson, M. D., Porter-Armstrong, A. & Eakin, P. Seat-interface pressure: A pilot study of the relationship to gender, body mass index, and seating position. Arch. Phys. Med. Rehabil. 84, 405–409. https://doi.org/10.1053/apmr.2003.50011 (2003). · doi:10.1053/apmr.2003.50011
  27. Chen, Y.-L. Changes in external ischial tuberosity width at varying trunk–thigh angles between sexes using two measurement methods. Sci. Rep. 11, 19676. https://doi.org/10.1038/s41598-021-99232-w (2021). · DOI

Metadata

Authors
Jarumethitanont, W., Manupibul, U., Tanthuwapathom, R., Prasertsukdee, S., Limroongreungrat, W., & Charoensuk, W.
Venue
Scientific Reports
Published
2024-09-18
Volume
14
Issue
1
ISSN
2045-2322
Cited by
8
References
2
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of low-cost pressure mapping device to evaluate force distribution for seat cushion modification. https://app.cochat.ai/papers/10.1038/s41598-024-72471-3
The paper
Jarumethitanont, W., Manupibul, U., Tanthuwapathom, R., Prasertsukdee, S., Limroongreungrat, W., & Charoensuk, W. (2024). Development of low-cost pressure mapping device to evaluate force distribution for seat cushion modification. Scientific Reports. https://doi.org/10.1038/s41598-024-72471-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.