Development and validation of an interpretable predictive machine learning model for successful weaning of continuous renal replacement therapy
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Continuous renal replacement therapy (CRRT) is a vital intervention for critically ill patients with severe acute kidney injury, yet no standardized criteria exist to determine the optimal time for its discontinuation. We developed and validated machine learning models to predict successful CRRT weaning, defined as survival without any form of renal replacement therapy for at least seven days after discontinuation. This retrospective multicenter study used data from two French university hospitals and the publicly available MIMIC-IV critical care database. Predictive variables were selected from routinely collected clinical and biological data to ensure real-world applicability. Models were trained on the Rouen cohort and externally validated on the Rennes and MIMIC-IV cohorts. Among the tested algorithms, the random forest model achieved the best performance, with an area under the receiver operating characteristic curve (AUROC) of 0.86 (95% CI, 0.82-0.91) in the training cohort, 0.81 (95% CI, 0.71-0.90) in the Rennes cohort, and 0.72 (95% CI, 0.65-0.78) in the MIMIC cohort. These results demonstrate the feasibility of a robust and interpretable prediction model that relies solely on routinely available data and has potential for integration into clinical workflows to support CRRT weaning decisions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
A New Equation to Estimate Glomerular Filtration Rate
Levey, A. S., Stevens, L. A., Schmid, C. H., Zhang, Y. (., Castro, A. F., Feldman, H. I., Kusek, J. W., Eggers, P., Van Lente, F., Greene, T., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-150-9-200905050-00006 · Cited by 25,603
KDIGO Clinical Practice Guidelines for Acute Kidney Injury
Khwaja, A. (2012) · Nephron Clinical Practice · doi:10.1159/000339789 · Cited by 8,014
Comparison of the predicted and observed secondary structure of T4 phage lysozyme
Matthews, B. W. (1975) · Biochimica et Biophysica Acta (BBA) - Protein Structure · doi:10.1016/0005-2795(75)90109-9 · Cited by 5,399
Collins, G. S., Moons, K. G. M., Dhiman, P., Riley, R. D., Beam, A. L., Van Calster, B., Ghassemi, M., Liu, X., Reitsma, J. B., van Smeden, M., et al. (2024) · BMJ · doi:10.1136/bmj-2023-078378 · Cited by 4,718 · cited 1×
“This article follows the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis Or Diagnosis – Artificial Intelligence (TRIPOD + AI) statement 36 ( Supplementary materials ).”
Uchino, S. (2005) · JAMA · doi:10.1001/jama.294.7.813 · Cited by 4,176
MIMIC-IV, a freely accessible electronic health record dataset
Johnson, A. E. W., Bulgarelli, L., Shen, L., Gayles, A., Shammout, A., Horng, S., Pollard, T. J., Hao, S., Moody, B., Gow, B., et al. (2023) · Scientific Data · doi:10.1038/s41597-022-01899-x · Cited by 3,401
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212 · cited 1×
“The involvement of clinicians throughout the CDSS development cycle is essential to avoid common pitfalls of developing models that are technically robust but poorly suited to clinical needs or workflows 22 .”
Global epidemiology and outcomes of acute kidney injury
Hoste, E. A. J., Kellum, J. A., Selby, N. M., Zarbock, A., Palevsky, P. M., Bagshaw, S. M., Goldstein, S. L., Cerdá, J., & Chawla, L. S. (2018) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0052-0 · Cited by 1,486
Komorowski, M., Celi, L. A., Badawi, O., Gordon, A. C., & Faisal, A. A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0213-5 · Cited by 1,290
Initiation strategies for renal-replacement therapy in the intensive care unit.
Gaudry, S., Hajage, D., Schortgen, F., Martin-Lefevre, L., Pons, B., Boulet, E., Boyer, A., Chevrel, G., Lerolle, N., Carpentier, D., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1603017 · Cited by 1,243
Optimal classifier for imbalanced data using Matthews Correlation Coefficient metric
Boughorbel, S., Jarray, F., & El-Anbari, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0177678 · Cited by 1,222
Timing of initiation of renal-replacement therapy in acute kidney injury.
The STARRT-AKI Investigators (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2000741 · Cited by 771
Barriers and facilitators to utilizing digital health technologies by healthcare professionals
Borges do Nascimento, I. J., Abdulazeem, H., Vasanthan, L. T., Martinez, E. Z., Zucoloto, M. L., Østengaard, L., Azzopardi-Muscat, N., Zapata, T., & Novillo-Ortiz, D. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00899-4 · Cited by 673
de Hond, A. A. H., Leeuwenberg, A. M., Hooft, L., Kant, I. M. J., Nijman, S. W. J., van Os, H. J. A., Aardoom, J. J., Debray, T. P. A., Schuit, E., van Smeden, M., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00549-7 · Cited by 499 · cited 1×
“This global approach aligns with modern guidelines for the development of CDSS, emphasizing iterative design, user-centered development, and rigorous evaluation 17,34 .”
The MIMIC Code Repository: enabling reproducibility in critical care research
Johnson, A. E. W., Stone, D. J., Celi, L. A., & Pollard, T. J. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocx084 · Cited by 442
Continuous Renal Replacement Therapy
Tandukar, S., & Palevsky, P. M. (2019) · Chest · doi:10.1016/j.chest.2018.09.004 · Cited by 336
Gaudry, S., Hajage, D., Martin-Lefevre, L., Lebbah, S., Louis, G., Moschietto, S., Titeca-Beauport, D., Combe, B. L., Pons, B., de Prost, N., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00350-0 · Cited by 288
van de Sande, D., van Genderen, M. E., Huiskens, J., Gommers, D., & van Bommel, J. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06446-7 · Cited by 279
Uchino, S., Bellomo, R., Morimatsu, H., Morgera, S., Schetz, M., Tan, I., Bouman, C., Macedo, E., Gibney, N., Tolwani, A., et al. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a38241 · Cited by 266
van de Sande, D., Van Genderen, M. E., Smit, J. M., Huiskens, J., Visser, J. J., Veen, R. E. R., van Unen, E., BA, O. H., Gommers, D., & Bommel, J. V. (2022) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2021-100495 · Cited by 135
Promoting Kidney Function Recovery in Patients with AKI Requiring RRT
Cerdá, J., Liu, K. D., Cruz, D. N., Jaber, B. L., Koyner, J. L., Heung, M., Okusa, M. D., & Faubel, S. (2015) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01170215 · Cited by 128
Katulka, R. J., Al Saadon, A., Sebastianski, M., Featherstone, R., Vandermeer, B., Silver, S. A., Gibney, R. T. N., Bagshaw, S. M., & Rewa, O. G. (2020) · Critical Care · doi:10.1186/s13054-020-2751-8 · Cited by 105
Identification of clinical subphenotypes of sepsis after laparoscopic surgery
Yang, J., Zhang, B., Hu, C., Jiang, X., Shui, P., Huang, J., Hong, Y., Ni, H., & Zhang, Z. (2024) · Laparoscopic Endoscopic and Robotic Surgery · doi:10.1016/j.lers.2024.02.001 · Cited by 83
Hong, N., Liu, C., Gao, J., Han, L., Chang, F., Gong, M., & Su, L. (2022) · JMIR Medical Informatics · doi:10.2196/28781 · Cited by 76
A Decision-Making Algorithm for Initiation and Discontinuation of RRT in Severe AKI
Mendu, M. L., Ciociolo, G. R., McLaughlin, S. R., Graham, D. A., Ghazinouri, R., Parmar, S., Grossier, A., Rosen, R., Laskowski, K. R., Riella, L. V., et al. (2017) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.07170716 · Cited by 72
Yang, J., Wang, L., Chen, L., Zhou, P., Yang, S., Shen, H., Xing, L., Chen, P., Yu, Y., Ni, H., et al. (2025) · Laparoscopic Endoscopic and Robotic Surgery · doi:10.1016/j.lers.2025.01.001 · Cited by 66
Mandl, B. J., & Reis, B. Y. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00554-w · Cited by 62
Pressat-Laffouilhère, T., Balayé, P., Dahamna, B., Lelong, R., Billey, K., Darmoni, S. J., & Julien Grosjean, A. (2022) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-022-01762-4 · Cited by 59
Self-citationFactors Predicting Successful Discontinuation of Continuous Renal Replacement Therapy
Katayama, S., Uchino, S., Uji, M., Ohnuma, T., Namba, Y., Kawarazaki, H., Toki, N., Takeda, K., Yasuda, H., Izawa, J., et al. (2016) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1604400401 · Cited by 53
Unnecessary Renal Replacement Therapy for Acute Kidney Injury is Harmful for Renal Recovery
Clark, E. G., & Bagshaw, S. M. (2015) · Seminars in Dialysis · doi:10.1111/sdi.12300 · Cited by 46
Successful weaning from continuous renal replacement therapy. Associated risk factors
Raurich, J. M., Llompart-Pou, J. A., Novo, M. A., Talavera, C., Ferreruela, M., & Ayestarán, I. (2018) · Journal of Critical Care · doi:10.1016/j.jcrc.2018.02.009 · Cited by 38
Liu, C., Peng, Z., Dong, Y., Zhuo, L., Andrijasevic, N. M., Albright, R. C., & KASHANI, K. B. (2021) · Journal of Critical Care · doi:10.1016/j.jcrc.2021.07.020 · Cited by 33
Schiffl, H. H., & Lang, S. M. (2020) · Molecular Diagnosis & Therapy · doi:10.1007/s40291-020-00498-z · Cited by 26
User-centred design for machine learning in health care: a case study from care management
Seneviratne, M. G., Li, R. C., Schreier, M., Lopez-Martinez, D., Patel, B. S., Yakubovich, A., Kemp, J. B., Loreaux, E., Gamble, P., El-Khoury, K., et al. (2022) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2022-100656 · Cited by 23
Liang, Q., Xu, X., Ding, S., Wu, J., & Huang, M. (2024) · Renal Failure · doi:10.1080/0886022x.2024.2319329 · Cited by 16
Sheng, S., Li, A., Liu, X., Shen, T., Zhou, W., Lv, X., Shen, Y., Wang, C., Ma, Q., Qu, L., et al. (2024) · BMC Nephrology · doi:10.1186/s12882-024-03844-z · Cited by 13
Zhong, L., Min, J., Zhang, J., Hu, B., & Qian, C. (2024) · iScience · doi:10.1016/j.isci.2024.110397 · Cited by 12
Xu, H., Ma, Y., Zhuang, Y., Zheng, Y., Du, Z., & Zhou, X. (2024) · Scientific Reports · doi:10.1038/s41598-024-71548-3 · Cited by 11
Popoff, B., Cabon, S., Cuggia, M., Bouzillé, G., & Clavier, T. (2025) · JMIR Medical Informatics · doi:10.2196/63709 · Cited by 6
Self-citationWang, T., Huang, C.-T., Wu, C., Chen, C., Wang, M.-S., Chao, W.-C., Huang, Y., & Pai, K.-C. (2024) · Scientific Reports · doi:10.1038/s41598-024-63992-y · Cited by 5
Jeon, J., Ko, E. J., Park, H., Baeg, S. I., Kim, H. D., Min, J. W., Koh, E. S., Lee, K., Kang, D., Cho, J., et al. (2024) · Kidney Research and Clinical Practice · doi:10.23876/j.krcp.23.308 · Cited by 4
(1950) · doi:10.1002/1097-0142(1950)3:1<32::aid-cncr2820030106>3.0.co;2-3
Research works printed but not linked: 8
- Rewa, O. G. et al. Epidemiology and outcomes of AKI treated with Continuous Kidney Replacement therapy: The Multicenter CRRTnet Study. Kidney Med. 5, 100641 (2023). 37274539 PMC10238597 · DOI
- Friedman, C. P. et al. The science of Learning Health Systems: Foundations for a new journal. Learning Health Syst. 1, e10020 (2017). PMC6516721 31245555 · DOI · Paper page
- Popoff, B. et al. How to accurately detect renal replacement therapy weaning in intensive care: Data quality and standardization considerations for the OMOP common data model. Stud. Health Technol. Inform. 316, 1584–1588 (2024). 39176511
- Toulouse, E., Lafont, B., Granier, S., Mcgurk, G. & Bazin, J.-E. French legal approach to patient consent in clinical research. Anaesth. Crit. Care Pain Med. 39, 883–885 (2020). 33130015
- Fröhlich, S., Donnelly, A., Solymos, O. & Conlon, N. Use of 2-hour creatinine clearance to guide cessation of continuous renal replacement therapy. J. Crit. Care 27 (744), e1-5 (2012). 23102534
- Madec, J. et al. eHOP Clinical Data Warehouse: From a Prototype to the Creation of an Inter-Regional Clinical Data Centers Network. Stud. Health Technol. Inform. 264, 1536–1537 (2019). 31438219
- Yap, E. et al. The implication of dropping race from the MDRD equation to estimate GFR in an African American-Only Cohort. Int J Nephrol 2021, 1880499 (2021). 34824870 PMC8610663 · DOI
- Herm, L.-V., Heinrich, K., Wanner, J. & Janiesch, C. Stop ordering machine learning algorithms by their explainability! A user-centered investigation of performance and explainability. Int. J. Inf. Manage. 69, 102538 (2023).
Metadata
- Authors
- Popoff, B., Delange, B., Nicolas, J., Le Gall, A., Dahamna, B., Cuggia, M., Clavier, T., & Bouzillé, G.
- Venue
- Scientific Reports
- Published
- 2025-11-28
- Volume
- 15
- Issue
- 1
- ISSN
- 2045-2322
- PMC
- PMC12663152
- Cited by
- 2
- References
- 43
- Language
- en
- Licence
- creativecommons.org/licenses/by-nc-nd/4.0 (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.