Full-waveform inversion imaging of the human brain
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging and X-ray computed tomography provide the two principal methods available for imaging the brain at high spatial resolution, but these methods are not easily portable and cannot be applied safely to all patients. Ultrasound imaging is portable and universally safe, but existing modalities cannot image usefully inside the adult human skull. We use in silico simulations to demonstrate that full-waveform inversion, a computational technique originally developed in geophysics, is able to generate accurate three-dimensional images of the brain with sub-millimetre resolution. This approach overcomes the familiar problems of conventional ultrasound neuroimaging by using the following: transcranial ultrasound that is not obscured by strong reflections from the skull, low frequencies that are readily transmitted with good signal-to-noise ratio, an accurate wave equation that properly accounts for the physics of wave propagation, and adaptive waveform inversion that is able to create an accurate model of the skull that then compensates properly for wavefront distortion. Laboratory ultrasound data, using ex vivo human skulls and in vivo transcranial signals, demonstrate that our computational experiments mimic the penetration and signal-to-noise ratios expected in clinical applications. This form of non-invasive neuroimaging has the potential for the rapid diagnosis of stroke and head trauma, and for the provision of routine monitoring of a wide range of neurological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inversion of seismic reflection data in the acoustic approximation
Tarantola, A. (1984) · Geophysics · doi:10.1190/1.1441754 · Cited by 3,759 · cited 2×
“In this paper, we present the neurological application of full-waveform inversion (FWI) [13], an imaging method first applied widely in geophysics [14].”
BackgroundMethodAn overview of full-waveform inversion in exploration geophysics
Virieux, J., & Operto, S. (2009) · Geophysics · doi:10.1190/1.3238367 · Cited by 3,750 · cited 8×
“It is also possible to use FWI to invert explicitly for attenuation and other parameters [14], and some pathologies may be more readily diagnosed using such multiparameter inversion than by use of acoustic wave speed alone.”
BackgroundMethodInfluentialEmberson, J., Lees, K. R., Lyden, P., Blackwell, L., Albers, G., Bluhmki, E., Brott, T., Cohen, G., Davis, S., Donnan, G., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60584-5 · Cited by 2,737
Donnan, G. A., Fisher, M., Macleod, M., & Davis, S. M. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60694-7 · Cited by 2,218
Multimodal population brain imaging in the UK Biobank prospective epidemiological study
Miller, K. L., Alfaro-Almagro, F., Bangerter, N. K., Thomas, D. L., Yacoub, E., Xu, J., Bartsch, A. J., Jbabdi, S., Sotiropoulos, S. N., Andersson, J. L. R., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4393 · Cited by 2,020
Pratt, R. G. (1999) · Geophysics · doi:10.1190/1.1444597 · Cited by 1,583
Comprehensive compilation of empirical ultrasonic properties of mammalian tissues
Goss, S. A., Johnston, R. L., & Dunn, F. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.382016 · Cited by 1,115 · cited 2×
“At the sub-MHz frequencies that were used in the numerical experiments, transmission losses in soft tissue are small [24, 31-36], but scattering and anelastic losses in the skull can be important [21-23].”
MethodFunctional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751 · cited 1×
“This method has produced promising results in rodents, generating functional ultrasound images that can capture transient changes in blood volume related to brain activity [11, 12], but this invasive approach has obvious limitations in clinical practice.”
MethodA Review of Tissue Substitutes for Ultrasound Imaging
Culjat, M. O., Goldenberg, D., Tewari, P., & Singh, R. S. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.012 · Cited by 659 · cited 2×
“At the sub-MHz frequencies that were used in the numerical experiments, transmission losses in soft tissue are small [24, 31-36], but scattering and anelastic losses in the skull can be important [21-23].”
MethodThinned-skull cranial window technique for long-term imaging of the cortex in live mice
Yang, G., Pan, F., Parkhurst, C. N., Grutzendler, J., & Gan, W.-B. (2010) · Nature Protocols · doi:10.1038/nprot.2009.222 · Cited by 440 · cited 1×
“This method has produced promising results in rodents, generating functional ultrasound images that can capture transient changes in blood volume related to brain activity [11, 12], but this invasive approach has obvious limitations in clinical practice.”
MethodAttenuation, scattering, and absorption of ultrasound in the skull bone
Pinton, G., Aubry, J.-F., Bossy, E., Muller, M., Pernot, M., & Tanter, M. (2011) · Medical Physics · doi:10.1118/1.3668316 · Cited by 405 · cited 4×
“At the sub-MHz frequencies that were used in the numerical experiments, transmission losses in soft tissue are small [24, 31-36], but scattering and anelastic losses in the skull can be important [21-23].”
BackgroundMethodInfluentialCompilation of empirical ultrasonic properties of mammalian tissues. II
Goss, S. A., Johnston, R. L., & Dunn, F. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384509 · Cited by 387
A Deep Cascade of Convolutional Neural Networks for MR Image Reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A., & Rueckert, D. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-59050-9_51 · Cited by 329 · cited 1×
“The patternrecognition abilities of modern machine learning are already making significant impact in medical imaging and analogous areas [30].”
BackgroundUltrasonic absorption and attenuation in mammalian tissues
Goss, S. A., Frizzell, L. A., & Dunn, F. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90086-3 · Cited by 313 · cited 2×
“At the sub-MHz frequencies that were used in the numerical experiments, transmission losses in soft tissue are small [24, 31-36], but scattering and anelastic losses in the skull can be important [21-23].”
MethodPichardo, S., Sin, V. W., & Hynynen, K. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/014 · Cited by 287 · cited 5×
“In contrast, the variation in wave speed for hard tissue in the cranium is larger at around ±14%, with values between about 2100 ms for cancellous bone and 2800 ms for cortical bone [21-23]; the mandible and the vertebrae have even higher wave speeds of around 3500 ms [24].”
BackgroundMethodInfluentialMIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Resolution in ultrasound imaging
Ng, A., & Swanevelder, J. (2011) · Continuing Education in Anaesthesia Critical Care & Pain · doi:10.1093/bjaceaccp/mkr030 · Cited by 232
Functional ultrasound imaging of brain activity in human newborns
Demene, C., Baranger, J., Bernal, M., Delanoe, C., Auvin, S., Biran, V., Alison, M., Mairesse, J., Harribaud, E., Pernot, M., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aah6756 · Cited by 207 · cited 1×
“One possible way around these problems is to use natural openings in the skull as acoustic windows, but this approach severely reduces illumination [5]; it is typically limited to neonates through an open fontanelle [10].”
BackgroundUltrasonic velocity and attenuation in mammalian tissues
Chivers, R. C., & Parry, R. J. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.381774 · Cited by 136 · cited 3×
“At the relatively low frequencies used in these simulations, such a model of absorption provides a reasonable approximation to the properties of real tissue [31].”
BackgroundMethodBritish Medical Ultrasound Society
Hall, A. J. (1984) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(84)90208-4 · Cited by 77
Percutaneous Clot Removal Devices in Acute Ischemic Stroke: A Systematic Review and Meta-analysis
Ganti, L., Gilmore, R. M., Bellolio, F., Rabinstein, A. A., & Decker, W. W. (2008) · Archives of Neurology · doi:10.1001/archneur.65.8.1024 · Cited by 56
Metadata
- Authors
- Guasch, L., Calderón Agudo, O., Tang, M.-X., Nachev, P., & Warner, M.
- Venue
- npj Digital Medicine
- Published
- 2020-03-06
- Volume
- 3
- Issue
- 1
- Pages
- 28-28
- ISSN
- 2398-6352 (ISSN-L)
- OpenAlex
- W3010498773
- Cited by
- 244
- References
- 21
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.