Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 405

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Attenuation, scattering, and absorption of ultrasound in the skull bone

Pinton, Gianmarco, Aubry, Jean-Francois, Bossy, Emmanuel, Muller, Marie, Pernot, Mathieu, Tanter, Mickael·2011·Medical Physics

Abstract

PURPOSE: Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its complex internal microstructure. Finally, part of the wave energy is absorbed by the bone and converted into heat. Due to the complexity of the wave propagation and the difficulty in performing measurements that are capable of separating the various loss mechanisms, there are currently no estimates of the absorption in bone. The aim of this paper is, thus, to quantify the attenuation, scattering, and thermal absorption in bone. METHODS: An attenuating model of wave propagation in bone is established and used to develop a three-dimensional finite difference time domain numerical algorithm. Hydrophone and optical heterodyne interferometer measurements of the acoustic field as well as a x-ray microtomography of the bone sample are used to drive the simulations and to measure the attenuation. The acoustic measurements are performed concurrently with an infrared camera that can measure the temperature elevation during insonication. A link between the temperature and the absorption via a three-dimensional thermal simulation is then used to quantify the absorption coefficients for longitudinal and shear waves in cortical bone. RESULTS: We demonstrate that only a small part of the attenuation is due to absorption in bone and that the majority of the attenuation is due to reflection, scattering, and mode conversion. In the nine samples of a human used for the study, the absorption time constant for cortical bone was determined to be 1.04 μs ± 28%. This corresponds to a longitudinal absorption of 2.7 dB/cm and a shear absorption of 5.4 dB/cm. The experimentally measured attenuation across the approximately 8 mm thick samples was 13.3 ± 0.97 dB/cm. CONCLUSIONS: This first measurement of ultrasound absorption in bone can be used to estimate the amount of heat deposition based on knowledge of the acoustic field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3668316

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 405

Metadata

Authors
Pinton, G., Aubry, J.-F., Bossy, E., Muller, M., Pernot, M., & Tanter, M.
Venue
Medical Physics
Publisher
Wiley
Published
2011-12-21
Volume
39
Issue
1
Pages
299-307
ISSN
0094-2405 (ISSN-L)
OpenAlex
W1988950556
Cited by
405
References
18
FWCI
10.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Attenuation, scattering, and absorption of ultrasound in the skull bone. https://app.cochat.ai/papers/10.1118/1.3668316
The paper
Pinton, G., Aubry, J.-F., Bossy, E., Muller, M., Pernot, M., & Tanter, M. (2011). Attenuation, scattering, and absorption of ultrasound in the skull bone. Medical Physics. https://doi.org/10.1118/1.3668316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.