Three-dimensional imaging of integrated circuits with macro- to nanoscale zoom
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
chambolle (2004) · doi:10.1023/b:jmiv.0000011321.19549.88 · Cited by 3,227
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,877
Formation of Optical Images by X-Rays
Kirkpatrick, P. H., & Baez, A. V. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000766 · Cited by 1,396
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Self-citationCrowther, R. A., DeRosier, D. J., & Klug, A. (1970) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1970.0119 · Cited by 972
Fourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927
Image Sharpening by Flows Based on Triple Well Potentials
Gilboa, G., Sochen, N., & Zeevi, Y. Y. (2004) · Journal of Mathematical Imaging and Vision · doi:10.1023/b:jmiv.0000011320.81911.38 · Cited by 616
An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Metrology for the next generation of semiconductor devices
Orji, N. G., Badaroglu, M., Barnes, B. M., Beitia, C., Bunday, B. D., Celano, U., Kline, R. J., Neisser, M., Obeng, Y., & Vladar, A. E. (2018) · Nature Electronics · doi:10.1038/s41928-018-0150-9 · Cited by 501
Cited by
Solid electrolyte interphases in lithium metal batteries
Jagger, B., & Pasta, M. (2023) · Joule · doi:10.1016/j.joule.2023.08.007 · Cited by 592
Optical wafer defect inspection at the 10 nm technology node and beyond
Zhu, J., Liu, J., Xu, T., Yuan, S., Zhang, Z., Jiang, H., Gu, H., Zhou, R., & Liu, S. (2022) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ac64d7 · Cited by 159
“Therefore, hard x-ray ptychography [177], to the best of our knowledge, is the only optical method that can directly image both surface and undersurface sub-20 nm defects for the entire wafer.”
Method
Metadata
- Authors
- Holler, M., Odstrcil, M., Guizar-Sicairos, M., Lebugle, M., Müller, E., Finizio, S., Tinti, G., David, C., Zusman, J., Unglaub, W., Bunk, O., Raabe, J., Levi, A. F. J., & Aeppli, G.
- Venue
- Nature Electronics
- Published
- 2019-10-07
- Volume
- 2
- Issue
- 10
- Pages
- 464-470
- ISSN
- 2520-1131 (ISSN-L)
- OpenAlex
- W2978997998
- Cited by
- 185
- References
- 31
- FWCI
- 13.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.