Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Early diagnosis of colorectal cancer substantially improves survival. However, over half of cases are diagnosed late due to the demand for colonoscopy—the ‘gold standard’ for screening—exceeding capacity. Colonoscopy is limited by the outdated design of conventional endoscopes, which are associated with high complexity of use, cost and pain. Magnetic endoscopes are a promising alternative and overcome the drawbacks of pain and cost, but they struggle to reach the translational stage as magnetic manipulation is complex and unintuitive. In this work, we use machine vision to develop intelligent and autonomous control of a magnetic endoscope, enabling non-expert users to effectively perform magnetic colonoscopy in vivo. We combine the use of robotics, computer vision and advanced control to offer an intuitive and effective endoscopic system. Moreover, we define the characteristics required to achieve autonomy in robotic endoscopy. The paradigm described here can be adopted in a variety of applications where navigation in unstructured environments is required, such as catheters, pancreatic endoscopy, bronchoscopy and gastroscopy. This work brings alternative endoscopic technologies closer to the translational stage, increasing the availability of early-stage cancer treatments. Magnetic endoscopes have the potential to improve access, reduce patient discomfort and enhance safety. While navigation of magnetic endoscopes can be challenging for the operator, a new approach by Martin, Scaglioni and colleagues explores how to reduce this burden by offering different levels of autonomy in robotic colonoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21492 · Cited by 84,109
Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research
(1988) · Advances in Psychology · doi:10.1016/s0166-4115(08)62386-9 · Cited by 20,029
Medical robotics—Regulatory, ethical, and legal considerations for increasing levels of autonomy
Yang, G.-Z., Cambias, J., Cleary, K., Daimler, E., Drake, J., Dupont, P. E., Hata, N., Kazanzides, P., Martel, S., Patel, R. V., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aam8638 · Cited by 741
Millimeter-scale flexible robots with programmable three-dimensional magnetization and motions
Xu, T., Zhang, J., Salehizadeh, M., Onaizah, O., & Diller, E. (2019) · Science Robotics · doi:10.1126/scirobotics.aav4494 · Cited by 696
Taxonomy and Definitions for Terms Related to On-Road Motor Vehicle Automated Driving Systems
On-Road Automated Driving (ORAD) Committee (2017) · doi:10.4271/j3016_201401 · Cited by 675
CAPABILITY MEASURES FOR m -DEPENDENT STATIONARY PROCESSES
CHEN, S.-M., HSU, Y.-S., & PEARN, W. L. (2003) · Statistics: A Journal of Theoretical and Applied Statistics · doi:10.1080/02331880309257 · Cited by 475
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
Autonomy for Surgical Robots: Concepts and Paradigms
Haidegger, T. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2913282 · Cited by 306
Mahoney, A. W., & Abbott, J. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914558006 · Cited by 285
Magnetically Actuated Soft Capsule Endoscope for Fine-Needle Biopsy
Son, D., Gilbert, H. B., & Sitti, M. (2019) · Soft Robotics · doi:10.1089/soro.2018.0171 · Cited by 248
Colorectal cancer screening: Estimated future colonoscopy need and current volume and capacity
Joseph, D. A., Meester, R. G. S., Zauber, A. G., Manninen, D. L., Winges, L., Dong, F. B., Peaker, B., & van Ballegooijen, M. (2016) · Cancer · doi:10.1002/cncr.30070 · Cited by 246
Control of Redundant Robots Under Hard Joint Constraints: Saturation in the Null Space
Flacco, F., De Luca, A., & Khatib, O. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2418582 · Cited by 221
Magnetically Controllable Gastrointestinal Steering of Video Capsules
Carpi, F., Kastelein, N., Talcott, M., & Pappone, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2087332 · Cited by 197
A Legged Anchoring Mechanism for Capsule Endoscopes Using Micropatterned Adhesives
Glass, P., Cheung, E., & Sitti, M. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002111 · Cited by 189
Mahoney, A. W., & Abbott, J. J. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2013.2289019 · Cited by 186
Colonoscopy training in gastroenterology fellowships: determining competence
Spier, B. J., Benson, M., Pfau, P. R., Nelligan, G., Lucey, M. R., & Gaumnitz, E. A. (2010) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2009.05.012 · Cited by 185
Six-degree-of-freedom magnetic actuation for wireless microrobotics
Diller, E., Giltinan, J., Lum, G. Z., Ye, Z., & Sitti, M. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915583539 · Cited by 169
Taddese, A. Z., Slawinski, P. R., Pirotta, M., Momi, E. D., Obstein, K. L., & Valdastri, P. (2018) · The International Journal of Robotics Research · doi:10.1177/0278364918779132 · Cited by 169
Self-citationMagnetically guided capsule endoscopy
Shamsudhin, N., Zverev, V. I., Keller, H., Pané, S., Egolf, P. W., Nelson, B. J., & Tishin, A. M. (2017) · Medical Physics · doi:10.1002/mp.12299 · Cited by 149
Intelligent magnetic manipulation for gastrointestinal ultrasound
Norton, J., Slawinski, P. R., Lay, H. S., Martin, J., Cox, B. F., Cummins, G., Desmulliez, M. P. Y., Clutton, R. E., Obstein, K. L., Cochran, S., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aav7725 · Cited by 143
Self-citationWilliams, C. B., & Teague, R. H. (1973) · Gut · doi:10.1136/gut.14.12.990 · Cited by 111
Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy
Valdastri, P., Ciuti, G., Verbeni, A., Menciassi, A., Dario, P., Arezzo, A., & Morino, M. (2011) · Surgical Endoscopy · doi:10.1007/s00464-011-2054-x · Cited by 103
Self-citationColonoscopy procedural skills and training for new beginners
Lee, S. H., Park, Y.-K., Lee, D.-J., & Kim, K.-M. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i45.16984 · Cited by 95 · cited 2×
“The velocity input imparting translational motion to the endoscope δXa, I is directly proportional to the alignment between the endoscopic image and the centre of the lumen, as described by equation (10) and shown in Extended data Fig.”
MethodA Simultaneous Calibration Method for Magnetic Robot Localization and Actuation Systems
Son, D., Dong, X., & Sitti, M. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2885218 · Cited by 92
Predictive factors affecting cecal intubation failure in colonoscopy trainees
Park, H. J., Hong, J. H., Kim, H., Kim, B. R., Park, S. Y., Jo, K. W., & Kim, J. W. (2013) · BMC Medical Education · doi:10.1186/1472-6920-13-5 · Cited by 69
Emerging issues and future developments in capsule endoscopy
Slawinski, P. R., Obstein, K. L., & Valdastri, P. (2015) · Techniques in Gastrointestinal Endoscopy · doi:10.1016/j.tgie.2015.02.006 · Cited by 68
Self-citationRobotic bronchoscopy drive mode of the Auris Monarch platform
Graetzel, C. F., Sheehy, A. J., & Noonan, D. P. (2019) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2019.8793704 · Cited by 67
Estimation-Based Control of a Magnetic Endoscope without Device Localization
Edelmann, J., Petruska, A. J., & Nelson, B. J. (2017) · Journal of Medical Robotics Research · doi:10.1142/s2424905x18500022 · Cited by 65
Explicit Model Predictive Control of a Magnetic Flexible Endoscope
Scaglioni, B., Previtera, L., Martin, J., Norton, J., Obstein, K. L., & Valdastri, P. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2893418 · Cited by 44
Self-citationComas, M., Mendívil, J., Andreu, M. G., Hernández, C., & Castells, X. (2016) · PLoS ONE · doi:10.1371/journal.pone.0164666 · Cited by 33
Exploring public opinion about liability and responsibility in surgical robotics
Jamjoom, A. A. B., Jamjoom, A. M., & Marcus, H. J. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-0169-2 · Cited by 26
Endo-VMFuseNet: A Deep Visual-Magnetic Sensor Fusion Approach for Endoscopic Capsule Robots
Turan, M., Almalıoğlu, Y., Gilbert, H. B., Sari, A. E., Soylu, U., & Sitti, M. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8461129 · Cited by 26
The toll of not screening for colorectal cancer
Chen, C., Hoffmeister, M., & Brenner, H. (2016) · Expert Review of Gastroenterology & Hepatology · doi:10.1080/17474124.2017.1264269 · Cited by 21
The efficacy of training insertion skill on a physical model colonoscopy simulator
Plooy, A. M., Hill, A., Horswill, M. S., Cresp, A. S. G., Karamatic, R., Riek, S. P., Wallis, G. M., Burgess-Limerick, R. J., Hewett, D. G., & Watson, M. (2016) · Endoscopy International Open · doi:10.1055/s-0042-114773 · Cited by 19
Wang, D., Xie, X., Li, G., Yin, Z., & Wang, Z. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2365016 · Cited by 13
Su1351 THE MAGNETIC FLEXIBLE ENDOSCOPE (MFE): A LEARNING CURVE ANALYSIS
Mamunes, A., Campisano, F., Martin, J., Scaglioni, B., Mazomenos, E. B., Valdastri, P., & Obstein, K. L. (2020) · Gastroenterology · doi:10.1016/s0016-5085(20)32106-5 · Cited by 1
Self-citation
Cited by
Magnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Telerobotic neurovascular interventions with magnetic manipulation
Kim, Y., Genevriere, E., Harker, P., Choe, J., Balicki, M., Regenhardt, R. W., Vranic, J. E., Dmytriw, A. A., Patel, A. B., & Zhao, X. (2022) · Science Robotics · doi:10.1126/scirobotics.abg9907 · Cited by 422
Autonomous robotic laparoscopic surgery for intestinal anastomosis
Saeidi, H., Opfermann, J. D., Kam, M., Wei, S., Leonard, S., Hsieh, M. H., Kang, J. U., & Krieger, A. (2022) · Science Robotics · doi:10.1126/scirobotics.abj2908 · Cited by 384
External Power-Driven Microrobotic Swarm: From Fundamental Understanding to Imaging-Guided Delivery
Wang, Q., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.0c07753 · Cited by 231
Dexterous helical magnetic robot for improved endovascular access
Dreyfus, R., Boehler, Q., Lyttle, S., Gruber, P., Lussi, J., Chautems, C., Gervasoni, S., Berberat, J., Seibold, D., Ochsenbein-Kölble, N., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adh0298 · Cited by 185
“Lightweight permanent magnet MNSs also exist ( 37 , 41 , 89 ).”
Background
Metadata
- Authors
- Martin, J. W., Scaglioni, B., Norton, J. C., Subramanian, V., Arezzo, A., Obstein, K. L., & Valdastri, P.
- Venue
- Nature Machine Intelligence
- Published
- 2020-10-12
- Volume
- 2
- Issue
- 10
- Pages
- 595-606
- ISSN
- 2522-5839 (ISSN-L)
- OpenAlex
- W3093713122
- Cited by
- 208
- References
- 36
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.