CoChat

Self-supervised retinal thickness prediction enables deep learning from unlabelled data to boost classification of diabetic retinopathy

Open access
Holmberg, Olle G., Köhler, Niklas D., Martins, Thiago, Siedlecki, Jakob, Herold, Tina, Keidel, Leonie, Asani, Ben, Schiefelbein, Johannes, Priglinger, Siegfried, Kortuem, Karsten U., Theis, Fabian J. · 2020 · Nature Machine Intelligence
Cited by 88

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Access to large, annotated samples represents a considerable challenge for training accurate deep-learning models in medical imaging. Although at present transfer learning from pre-trained models can help with cases lacking data, this limits design choices and generally results in the use of unnecessarily large models. Here we propose a self-supervised training scheme for obtaining high-quality, pre-trained networks from unlabelled, cross-modal medical imaging data, which will allow the creation of accurate and efficient models. We demonstrate the utility of the scheme by accurately predicting retinal thickness measurements based on optical coherence tomography from simple infrared fundus images. Subsequently, learned representations outperformed advanced classifiers on a separate diabetic retinopathy classification task in a scenario of scarce training data. Our cross-modal, three-stage scheme effectively replaced 26,343 diabetic retinopathy annotations with 1,009 semantic segmentations on optical coherence tomography and reached the same classification accuracy using only 25% of fundus images, without any drawbacks, since optical coherence tomography is not required for predictions. We expect this concept to apply to other multimodal clinical imaging, health records and genomics data, and to corresponding sample-starved learning problems. The thickness of the retina is an important medical indicator for diabetic retinopathy. Holmberg and colleagues present a self-supervised deep-learning method that uses cross-modal data to predict retinal thickness maps from easily obtainable fundus images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s42256-020-00247-1

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 88

Metadata

Authors
Holmberg, O. G., Köhler, N. D., Martins, T., Siedlecki, J., Herold, T., Keidel, L., Asani, B., Schiefelbein, J., Priglinger, S., Kortuem, K. U., & Theis, F. J.
Venue
Nature Machine Intelligence
Published
2020-11-09
Volume
2
Issue
11
Pages
719-726
ISSN
2522-5839 (ISSN-L)
OpenAlex
W3102174132
Cited by
88
References
17
FWCI
5.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-supervised retinal thickness prediction enables deep learning from unlabelled data to boost classification of diabetic retinopathy. https://app.cochat.ai/papers/10.1038/s42256-020-00247-1
The paper
Holmberg, O. G., Köhler, N. D., Martins, T., Siedlecki, J., Herold, T., Keidel, L., Asani, B., Schiefelbein, J., Priglinger, S., Kortuem, K. U., & Theis, F. J. (2020). Self-supervised retinal thickness prediction enables deep learning from unlabelled data to boost classification of diabetic retinopathy. Nature Machine Intelligence. https://doi.org/10.1038/s42256-020-00247-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.