CoChat

Bioinspired acousto-magnetic microswarm robots with upstream motility

Open access
Ahmed, Daniel, Sukhov, Alexander, Hauri, David, Rodrigue, Dubon, Maranta, Gian, Harting, Jens, Nelson, Bradley J. · 2021 · Nature Machine Intelligence
Cited by 172

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The ability to propel against flows, that is, to perform positive rheotaxis, can provide exciting opportunities for applications in targeted therapeutics and non-invasive surgery. So far no biocompatible technologies exist for navigating microparticles upstream when they are in a background fluid flow. Inspired by many naturally occurring microswimmers—such as bacteria, spermatozoa and plankton—that utilize the no-slip boundary conditions of the wall to exhibit upstream propulsion, here we report on the design and characterization of self-assembled microswarms that can execute upstream motility in a combination of external acoustic and magnetic fields. Both acoustic and magnetic fields are safe to humans, non-invasive, can penetrate deeply into the human body and are well-developed in clinical settings. The combination of both fields can overcome the limitations encountered by single actuation methods. The design criteria of the acoustically induced reaction force of the microswarms, which is needed to perform rolling-type motion, are discussed. We show quantitative agreement between experimental data and our model that captures the rolling behaviour. The upstream capability provides a design strategy for delivering small drug molecules to hard-to-reach sites and represents a fundamental step towards the realization of micro- and nanosystem navigation against the blood flow. Microrobotics offers great potential for precise drug delivery as medication can be released in the bloodstream only where it is needed. But the dynamic environment of the bloodstream is a challenge for navigation. An approach presented by Ahmed and colleagues combines magnetic and acoustic fields to allow swarms of particles to swim against a current.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s42256-020-00275-x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 172

Metadata

Authors
Ahmed, D., Sukhov, A., Hauri, D., Rodrigue, D., Maranta, G., Harting, J., & Nelson, B. J.
Venue
Nature Machine Intelligence
Published
2021-01-11
Volume
3
Issue
2
Pages
116-124
ISSN
2522-5839 (ISSN-L)
OpenAlex
W3030559520
Cited by
172
References
2
FWCI
12.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioinspired acousto-magnetic microswarm robots with upstream motility. https://app.cochat.ai/papers/10.1038/s42256-020-00275-x
The paper
Ahmed, D., Sukhov, A., Hauri, D., Rodrigue, D., Maranta, G., Harting, J., & Nelson, B. J. (2021). Bioinspired acousto-magnetic microswarm robots with upstream motility. Nature Machine Intelligence. https://doi.org/10.1038/s42256-020-00275-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.