CoChat

Deep reinforcement learning-designed radiofrequency waveform in MRI

Shin, Dongmyung, Kim, Younghoon, Oh, Chungseok, An, Hongjun, Park, Juhyung, Kim, Jiye, Lee, Jongho · 2021 · Nature Machine Intelligence
Cited by 35

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Carefully engineered radiofrequency (RF) pulses play a key role in a number of systems such as mobile phone, radar and magnetic resonance imaging. The design of an RF waveform, however, is often posed as an inverse problem with no general solution. As a result, various design methods, each with a specific purpose, have been developed on the basis of the intuition of human experts. In this work we propose an artificial intelligence (AI)-powered RF pulse design framework, DeepRF, which utilizes the self-learning characteristics of deep reinforcement learning to generate a novel RF pulse. The effectiveness of DeepRF is demonstrated using four types of RF pulses that are commonly used. The DeepRF-designed pulses successfully satisfy the design criteria while reporting reduced energy. Analyses demonstrate the pulses utilize new mechanisms of magnetization manipulation, suggesting the potentials of DeepRF in discovering unseen design dimensions beyond human intuition. This work may lay the foundation for an emerging field of AI-driven RF waveform design. Radiofrequency pulses of different shapes can increase the efficiency of applications such as broadcasting or medical imaging, but finding the optimal shape for a specific use can be computationally costly. Shin and colleagues present a new method based on deep reinforcement learning to design radiofrequency pulses for use in MRI, which is demonstrated to cover different types of optimization goals for each application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s42256-021-00411-1

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 41

  1. Silver, D. et al. Mastering the game of Go without human knowledge. Nature 550, 354–359 (2017). · DOI · Paper page
  2. Runge, F., Stoll, D., Falkner, S. & Hutter, F. Learning to design RNA. In Proc. International Conference on Learning Representations (2019).
  3. Wang, H., Yang, J., Lee, H.-S. & Han, S. Learning to design circuits. In Proc. Conference on Neural Information Processing Systems (2018).
  4. Popova, M., Isayev, O. & Tropsha, A. Deep reinforcement learning for de novo drug design. Sci. Adv. 4, aap7885 (2018). · DOI · Paper page
  5. Sutton, R. S. & Barto, A. G. Reinforcement Learning: An Introduction (MIT Press, 2018).
  6. Bell, M. R. Information theory and radar waveform design. IEEE Trans. Inf. Theory 39, 1578–1597 (1993). · DOI · Paper page
  7. Simpson, D. H., Chin, C. T. & Burns, P. N. Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 46, 372–382 (1999). · doi:10.1109/58.753026
  8. Tarantola, A. Inverse Problem Theory and Methods for Model Parameter Estimation (SIAM, 2005). · DOI · Paper page
  9. Bloch, F. Nuclear induction. Phys. Rev. 70, 460 (1946). · DOI · Paper page
  10. Pauly, J., Le Roux, P., Nishimura, D. & Macovski, A. Parameter relations for the Shinnar–Le Roux selective excitation pulse design algorithm. IEEE Trans. Med. Imaging 10, 53–65 (1991). · DOI · Paper page
  11. Abragam, A. The Principles of Nuclear Magnetism (Oxford Univ. Press, 1961). · DOI
  12. Conolly, S., Nishimura, D. & Macovski, A. Optimal control solutions to the magnetic resonance selective excitation problem. IEEE Trans. Med. Imaging 5, 106–115 (1986). · DOI · Paper page
  13. Rosenfeld, D. & Zur, Y. Design of adiabatic selective pulses using optimal control theory. Magn. Reson. Med. 36, 401–409 (1996). · DOI
  14. Rund, A., Aigner, C. S., Kunisch, K. & Stollberger, R. Magnetic resonance RF pulse design by optimal control with physical constraints. IEEE Trans. Med. Imaging 37, 461–472 (2017). · DOI
  15. Rund, A., Aigner, C. S., Kunisch, K. & Stollberger, R. Simultaneous multislice refocusing via time optimal control. Magn. Reson. Med. 80, 1416–1428 (2018). · DOI
  16. Xu, D., King, K. F., Zhu, Y., McKinnon, G. C. & Liang, Z. P. Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approach. Magn. Reson. Med. 59, 547–560 (2008). · DOI
  17. Vinding, M. S., Maximov, I. I., Tošner, Z. & Nielsen, N. C. Fast numerical design of spatial-selective RF pulses in MRI using Krotov and quasi-Newton based optimal control methods. J. Chem. Phys. 137, 054203 (2012). · DOI
  18. Vinding, M. S., Guérin, B., Vosegaard, T. & Nielsen, N. C. Local SAR, global SAR, and power‐constrained large‐flip‐angle pulses with optimal control and virtual observation points. Magn. Reson. Med. 77, 374–384 (2017). · DOI
  19. Loecher, M., Magrath, P., Aliotta, E. & Ennis, D. B. Time‐optimized 4D phase contrast MRI with real‐time convex optimization of gradient waveforms and fast excitation methods. Magn. Reson. Med. 82, 213–224 (2019). · doi:10.1002/mrm.27716
  20. Shang, H. et al. Multiband RF pulses with improved performance via convex optimization. J. Magn. Reson. 262, 81–90 (2016). · DOI
  21. Vinding, M. S., Aigner, C. S., Schmitter, S. & Lund, T. E. DeepControl: 2D RF pulses facilitating B1+ inhomogeneity and B0 off-resonance compensation in vivo at 7T. Magn. Reson. Med. 85, 3308–3317 (2021). · DOI
  22. Vinding, M. S., Skyum, B., Sangill, R. & Lund, T. E. Ultrafast (milliseconds), multidimensional RF pulse design with deep learning. Magn. Reson. Med. 82, 586–599 (2019). · DOI · Paper page
  23. Mirfin, C., Glover, P. & Bowtell, R. Optimisation of parallel transmission radiofrequency pulses using neural networks. In Proc. 26th Annual Meeting of ISMRM (2018).
  24. Zhang, Y. et al. Multi‐task convolutional neural network‐based design of radio frequency pulse and the accompanying gradients for magnetic resonance imaging. NMR Biomed. 34, e4443 (2021). · DOI
  25. Goodfellow, I., Bengio, Y., Courville, A. & Bengio, Y. Deep Learning (MIT Press, 2016).
  26. Silver, M. S., Joseph, R. & Hoult, D. Highly selective π2 and π pulse generation. J. Magn. Reson. 59, 347–351 (1984).
  27. Tannús, A. & Garwood, M. Adiabatic pulses. NMR Biomed. 10, 423–434 (1997). · DOI · Paper page
  28. Glorot, X. & Bengio, Y. Understanding the difficulty of training deep feedforward neural networks. In Proc. International Conference on Artificial Intelligence and Statistics 249–256 (2010).
  29. Zhu, B., Liu, J. Z., Koonjoo, N., Rose, B. R. & Rosen, M. S. Automated pulse sequence generation (AUTOSEQ) using Bayesian reinforcement learning in an MRI physics simulation environment. In Proc. 26th Annual Meeting of ISMRM (2018).
  30. Walker-Samuel, S. Using deep reinforcement learning to actively, adaptively and autonomously control of a simulated MRI scanner. In Proc. 27th Annual Meeting of ISMRM (2019).
  31. David, Y. et al. Reinforcement learning for online undersampling pattern optimization. In Proc. 27th Annual Meeting of ISMRM (2019).
  32. Pineda, L., Basu, S., Romero, A., Calandra, R. & Drozdzal, M. Active MR k-space sampling with reinforcement learning. Proc. International Conference on Medical Image Computing and Computer-Assisted Intervention (2020). · DOI
  33. Bahadir, C. D., Wang, A. Q., Dalca, A. V. & Sabuncu, M. R. Deep-learning-based optimization of the under-sampling pattern in MRI. IEEE Trans. Comput. Imaging 6, 1139–1152 (2020). · DOI
  34. Meyer, C. H., Pauly, J. M., Macovskiand, A. & Nishimura, D. G. Simultaneous spatial and spectral selective excitation. Magn. Reson. Med. 15, 287–304 (1990). · DOI · Paper page
  35. Yip, C. Y., Fessler, J. A. & Noll, D. C. Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation. Magn. Reson. Med. 54, 908–917 (2005). · doi:10.1002/mrm.20631
  36. Cho, K. et al. Learning phrase representations using RNN encoder–decoder for statistical machine translation. In Proc. Conference on Empirical Methods in Natural Language Processing (2014). · DOI · Paper page
  37. Paszke, A. et al. Automatic differentiation in pytorch. In Proc. Conference on Neural Information Processing Systems (2017).
  38. Kingma, D. P. & Ba, J. Adam: a method for stochastic optimization. In Proc. International Conference for Learning Representations (2015).
  39. Matson, G. B. An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients. Magn. Reson. Imaging 12, 1205–1225 (1994). · DOI
  40. Martin, J. B. et al. SigPy.RF: comprehensive open-source RF pulse design tools for reproducible research. In Proc. 28th Annual Meeting of ISMRM (2020).
  41. Stockmann, J. P. et al. A 32‐channel combined RF and B0 shim array for 3T brain imaging. Magn. Reson. Med. 75, 441–451 (2016). · DOI

Metadata

Authors
Shin, D., Kim, Y., Oh, C., An, H., Park, J., Kim, J., & Lee, J.
Venue
Nature Machine Intelligence
Published
2021-11-16
Volume
3
Issue
11
Pages
985-994
ISSN
2522-5839
Cited by
35
References
9
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.