Wearable flexible microfluidic sensing technologies
The DOI matches its Crossref record; 218 of the 218 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–218 of 218
Survey of Saliva Components and Virus Sensors for Prevention of COVID-19 and Infectious Diseases
Dave, P., Rojas‐Cessa, R., Dong, Z., & Umpaichitra, V. (2020) · Biosensors · doi:10.3390/bios11010014 · Cited by 43 · cited 1×
“Saliva is composed of ~98.5% water and ~1.5% biochemicals, including ions, metabolites, enzymes (for example, amylase, lingual lipase lysozyme, peroxidase and lipase), hormones (for example, cortisol), proteins (for example, mucin and cytokines) and microorganisms 197 .”
BackgroundInfluentialInterstitial Fluid Behavior and Diseases
Liu, W., Cao, Y., Zhou, X., & Han, D. (2022) · Advanced Science · doi:10.1002/advs.202100617 · Cited by 40
Agustini, D., Caetano, F. R., Quero, R. F., da Silva, J. A. F., Bergamini, M. F., Junior, L. H. M., & de Jesus, D. P. (2021) · Analytical Methods · doi:10.1039/d1ay01337h · Cited by 40 · cited 1×
“Fibrous flexible microfluidic sensing platforms are typically made of paper 35,36 , thread or yarn 37 , or textile substrates 38 .”
BackgroundHuynh, V. L., Trung, T. Q., Meeseepong, M., Lee, H., Nguyen, T. D., & Lee, N. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004684 · Cited by 39 · cited 11×
“…the concentration of ammonium ions in sweat can be related to liver and kidney function as well as exercise intensity 8 ; sweat glucose levels can be related to blood glucose for diabetes diagnosis 175 ; sweat neuropeptide Y and cortisol levels show good correlation with those in blood 8,28,78 .”
BackgroundMethodInfluentialFlow stabilization in wearable microfluidic sensors enables noise suppression
Araci, I. E., Ağaoğlu, S., Lee, J. Y., Yepes, L. R., Diep, P., Martini, M., & Schmidt, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00842j · Cited by 38 · cited 1×
“Strain and pressure can also be detected using microchannels with an outlet and encased gas; here, the ratio of fluid and gas in the channel changes under different strains or pressures, which can be exploited as a pressure meter to indicate intraocular pressure 165 .”
BackgroundSelf-citationCurrent and Future Perspectives on Microfluidic Tear Analytic Devices
Li, M. S., Wong, H. L., Ip, Y. L., Peng, Z., Yiu, R. S. W., Yuan, H. R., Wong, J. K. W., & Chan, Y. K. (2022) · ACS Sensors · doi:10.1021/acssensors.2c00569 · Cited by 37 · cited 2×
“Such systems also allow closed-loop drug delivery into tears 210,214 .”
BackgroundBae, C. W., Chinnamani, M. V., Lee, E. H., & Lee, N. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202200492 · Cited by 35 · cited 1×
“NFC-embedded systems 48,151,166 typically contain an external NFC reader (usually an NFC-enabled smartphone with NFC coils), an onboard antenna coil, an NFC system-on-chip with a built-in controller, analogue front-end and sensors.”
BackgroundRecombinant Antibody Engineering Enables Reversible Binding for Continuous Protein Biosensing
Fercher, C., Jones, M. L., Mahler, S. M., & Corrie, S. R. (2021) · ACS Sensors · doi:10.1021/acssensors.0c01510 · Cited by 34
Bio-sensing textiles - Wearable Chemical Biosensors for Health Monitoring
Coyle, S. M., Wu, Y., Lau, K., Brady, S. A., Wallace, G. G., & Diamond, D. (2007) · Springer eBooks · doi:10.1007/978-3-540-70994-7_6 · Cited by 34 · cited 2×
“…and analysis modules and worn by people with minimum disruption to their daily activities 3–5, 16, With the development of flexible microfluidic 22 and wearable flexible sensors 7–15 , various fibrous 23–25 and polymer-based 26 flexible wearable microfluidic sensors have been developed (Fig.”
BackgroundMethodDynamic changes in salivary cortisol and secretory immunoglobulin A response to acute stress
Fan, Y., Tang, Y., Lu, Q., Feng, S., Yu, Q., Sui, D., Zhao, Q., Ma, Y., & Li, S. (2009) · Stress and Health · doi:10.1002/smi.1239 · Cited by 32 · cited 1×
“The saliva composition is influenced by diet, disease, drugs and physiological states such as fatigue and stress 199 .”
BackgroundAffinity‐Based Wearable Electrochemical Biosensors: Natural versus Biomimetic Receptors
Campuzano, S., Pedrero, M., Torrente-Rodríguez, R. M., & Pingarrón, J. M. (2022) · Analysis & Sensing · doi:10.1002/anse.202200087 · Cited by 32
Tear Film Volume and Protein Analysis in Full-term Newborn Infants
Esmaeelpour, M., Watts, P., Boulton, M. E., Cai, J., & Murphy, P. J. (2010) · Cornea · doi:10.1097/ico.0b013e3181f22cd9 · Cited by 31 · cited 1×
“203).”
Abbasiasl, T., Mirlou, F., Istif, E., Koydemir, H. C., & Beker, L. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00032f · Cited by 28
A Matrix Metalloproteinase Sensing Biosensor for the Evaluation of Chronic Wounds
Kang, S. M., Cho, H., Jeon, D., Park, S. H., Shin, D., & Heo, C. Y. (2019) · BioChip Journal · doi:10.1007/s13206-019-3403-4 · Cited by 24 · cited 1×
“High levels of MMPs, in particular, MMP2, may be related to wound exacerbation 192 ; similarly, MMP levels can be assessed to monitor the therapeutic effect of MMP inhibitors in wound healing 193 .”
BackgroundJiang, H., Woodhouse, I., Selvamani, V., Ma, J. L., Tang, R., Goergen, C. J., Soleimani, T., & Rahimi, R. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3015485 · Cited by 22 · cited 1×
“Similar designs have been used for contact lenses integrating eye pressure sensors 130,206 and intra-abdominal pressure sensors 218 .”
MethodTakashima, A., Kojima, K., & Suzuki, H. R. (2010) · Analytical Chemistry · doi:10.1021/ac1009657 · Cited by 20 · cited 1×
“peroxide 87 and sodium bicarbonate 51 can be applied to generate oxygen and carbon dioxide, respectively, to drive flow.”
MethodChoi, J.-Y., Park, D.-W., & Oh, T. S. (2014) · Journal of the Microelectronics and Packaging Society · doi:10.6117/kmeps.2014.21.4.125 · Cited by 14
Jeerapan, I., Moonla, C., Thavarungkul, P., & Kanatharana, P. (2022) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2021.07.025 · Cited by 9
Cited by
Motion artefact management for soft bioelectronics
Yin, J., Wang, S., Tat, T., & Chen, J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00175-4 · Cited by 220
“Furthermore, current signal acquisition techniques (potentiom-etry, amperometry, voltammetry and impedance spectroscopy) are affected by the dynamic state of biofluids that contain the biomarkers, which may cause signal drift and performance deterioration during body activities 3,176 .”
Diving into Sweat: Advances, Challenges, and Future Directions in Wearable Sweat Sensing
Childs, A., Mayol, B., Lasalde-Ramírez, J. A., Song, Y., Sempionatto, J. R., & Gao, W. (2024) · ACS Nano · doi:10.1021/acsnano.4c10344 · Cited by 217
“45,46 Nanotechnology has played a crucial role in enhancing the mechanical resilience and electrical performance of elastic substrates.”
Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring
Duan, H., Peng, S., He, S., Tang, S., Goda, K., Wang, C. H., & Li, M. (2025) · Advanced Science · doi:10.1002/advs.202411433 · Cited by 195
Chen, S., Fan, S., Qiao, Z., Wu, Z., Lin, B., Li, Z., Riegler, M. A., Wong, M. Y. H., Opheim, A., Korostynska, O., et al. (2025) · Advanced Materials · doi:10.1002/adma.202500412 · Cited by 164
Self-citation
Metadata
- Authors
- Chen, S., Qiao, Z., Niu, Y., Yeo, J. C., Liu, Y., Qi, J., Fan, S., Liu, X., Lee, J. Y., & Lim, C. T.
- Venue
- Nature Reviews Bioengineering
- Published
- 2023-09-08
- Volume
- 1
- Issue
- 12
- Pages
- 950-971
- ISSN
- 2731-6092 (ISSN-L)
- OpenAlex
- W4386547330
- Cited by
- 168
- References
- 218
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.