Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 220

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Motion artefact management for soft bioelectronics

Open access
Yin, Junyi, Wang, Shaolei, Tat, Trinny, Chen, Jun · 2024 · Nature Reviews Bioengineering

Abstract

Soft bioelectronic devices can be interfaced with anatomically curved organs, such as the heart, brain and skin, to provide continuous analysis of physiological information. However, body movements and physiological activities may induce motion artefacts, which can adversely affect signal accuracy and stability. Importantly, motion artefact management is key to promoting the clinical translation of soft bioelectronics to ensure that soft bioelectronic devices can selectively detect target biological signals with high accuracy. In this Review, we discuss how body activities can affect the soft bioelectronic–tissue interface and result in motion artefact signals, including interface impedance instability motion artefacts, biopotential motion artefacts and mechanical motion artefacts. We then investigate different motion artefact management strategies, including materials engineering, device and circuit design, and algorithmic intervention, to reduce the contribution of motion artefacts to signal acquisition, processing and interpretation. Motion artefacts challenge the translational application of soft bioelectronics by distorting physiological monitoring. This Review introduces fundamental causes of motion artefacts and discusses various management strategies, including materials usage, bioelectronics design and algorithmic intervention. Soft bioelectronic systems for the monitoring of human health rely on a stable and conformal bioelectronic–tissue interface. Motion artefacts can occur due to body movements and physiological activities, and can negatively affect signal detection and interpretation in bioelectronic measurements. Motion artefact management is crucial to the clinical translation of soft bioelectronics to ensure measurement with high accuracy. Materials usage, device design, bioelectronic–tissue adhesion, sensor and circuit designs, and algorithmic intervention are effective motion artefact management strategies. Soft bioelectronic systems for the monitoring of human health rely on a stable and conformal bioelectronic–tissue interface. Motion artefacts can occur due to body movements and physiological activities, and can negatively affect signal detection and interpretation in bioelectronic measurements. Motion artefact management is crucial to the clinical translation of soft bioelectronics to ensure measurement with high accuracy. Materials usage, device design, bioelectronic–tissue adhesion, sensor and circuit designs, and algorithmic intervention are effective motion artefact management strategies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s44222-024-00175-4

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 220

Metadata

Authors
Yin, J., Wang, S., Tat, T., & Chen, J.
Venue
Nature Reviews Bioengineering
Published
2024-04-15
Volume
2
Issue
7
Pages
541-558
ISSN
2731-6092 (ISSN-L)
OpenAlex
W4394805847
Cited by
220
References
31
FWCI
14.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion artefact management for soft bioelectronics. https://app.cochat.ai/papers/10.1038/s44222-024-00175-4
The paper
Yin, J., Wang, S., Tat, T., & Chen, J. (2024). Motion artefact management for soft bioelectronics. Nature Reviews Bioengineering. https://doi.org/10.1038/s44222-024-00175-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.