Patient preferences for next generation neural prostheses to restore bladder function
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Study design:A survey administered to 66 individuals with spinal cord injury (SCI) implementing a choice-based conjoint (CBC) analysis. Six attributes with three levels each were defined and used to generate choice sets with treatment scenarios. Patients were asked to choose the scenario that they preferred most.Objectives:To determine the utility weights for treatment characteristics as well as the overall preference for the three types of neural prostheses (NP), that is Brindley, rhizotomy-free Brindley, and pudendal nerve stimulation. Earlier studies have revealed the importance of restoration of bladder function, but no studies have been performed to determine the importance of NP features.Setting:Two academic affiliated medical systems’ SCI outpatient and inpatient rehabilitation programs, Cleveland, OH.Methods:CBC analysis followed by multinomial logit modeling. Individual part-worth utilities were estimated using hierarchical Bayes.Results:Side effects had the greatest significant impact on subject choices, followed by the effectiveness on continence and voiding. NPs with rhizotomy-free sacral root stimulation were preferred (45% first choice) over pudendal afferent nerve stimulation (39% second choice) and sacral root stimulation with rhizotomy (53% third choice). Almost 20% did not want to have an NP at all times.Conclusion:CBC has shown to be a valuable tool to support design choices. The data showed that persons would prefer a bladder NP with minimally invasive electrodes, which would give them complete bladder function, with no side effects and that can be operated by pushing a button and they do not have to recharge themselves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Conducting Discrete Choice Experiments to Inform Healthcare Decision Making: A User??s Guide
Lancsar, E., & Louviere, J. (2008) · PharmacoEconomics · doi:10.2165/00019053-200826080-00004 · Cited by 1,707
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Cited by
Hauber, A. B., González, J. M., Groothuis-Oudshoorn, C. G. M., Prior, T., Marshall, D. A., Cunningham, C., IJzerman, M. J., & Bridges, J. F. P. (2016) · Value in Health · doi:10.1016/j.jval.2016.04.004 · Cited by 1,330
“Although early applications were used to quantify process utility [9,10], more recent applications have focused on patient preferences for health status [11,12], screening [13], prevention [14,15], pharmaceutical treatment [16,17], therapeutic devices [18,19], diagnostic testing [20,21], and end-of-life care [22,23].”
BackgroundMethodSelf-citationA Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123
“However, most of the patients with spinal cord injury would still prefer improved neural prostheses (13).”
BackgroundMEDICAL DEVICES EARLY ASSESSMENT METHODS: SYSTEMATIC LITERATURE REVIEW
Markiewicz, K., van Til, J. A., & IJzerman, M. J. (2014) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462314000026 · Cited by 87
“To include stakeholder perspectives in further development of a medical device [44] [45]; [46] [47]; [48] [49]; [50]; [51]; [52]; [53]; [54]; [55]; [56]; [57]; [58]; [59] [60] [61]”
Self-citationDelivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68
Metadata
- Authors
- Sanders, P. M. H., IJzerman, M. J., Roach, M. J., & Gustafson, K. J.
- Venue
- Spinal Cord
- Published
- 2010-06-08
- Volume
- 49
- Issue
- 1
- Pages
- 113-119
- ISSN
- 1362-4393 (ISSN-L)
- 1476-5624
- OpenAlex
- W2013639233
- Cited by
- 27
- References
- 3
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient preferences for next generation neural prostheses to restore bladder function. https://app.cochat.ai/papers/10.1038/sc.2010.65
- The paper
- Sanders, P. M. H., IJzerman, M. J., Roach, M. J., & Gustafson, K. J. (2011). Patient preferences for next generation neural prostheses to restore bladder function. Spinal Cord. https://doi.org/10.1038/sc.2010.65
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.