A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
An electronic interface for recording and stimulating nerves that innervate the bladder helps to restore normal bladder function in rats with spinal cord injury.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the severe implantation trauma caused by the full dissection of the epineurium can lead to axon damage, certain nerves are able to support this implantation procedure (Chew et al., 2013).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Chew et al., 2013
In the citing paper
“Microchannels were implanted on the dorsal surface of the S1-S2 spinal cord for feedback control of bladder functions [Fig.4(j)] 110”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [110]
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
The neural control of micturition
Fowler, C. J., Griffiths, D., & de Groat, W. C. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2401 · Cited by 1,485
Conduction velocity is related to morphological cell type in rat dorsal root ganglion neurones.
Harper, A. A., & Lawson, S. N. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015573 · Cited by 745
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313
Sengupta, J. N., & Gebhart, G. F. (1994) · Journal of Neurophysiology · doi:10.1152/jn.1994.72.5.2420 · Cited by 246
High‐frequency electrical conduction block of mammalian peripheral motor nerve
Bhadra, N., & Kilgore, K. L. (2005) · Muscle & Nerve · doi:10.1002/mus.20428 · Cited by 239
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177
Electrophysiological study of micturition reflexes in rats
Mallory, B., Steers, W. D., & De Groat, W. C. (1989) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1989.257.2.r410 · Cited by 169
Cited by
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Self-citationTopological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Choi, S., Han, S. I., Kim, D., Hyeon, T., & Kim, D.-H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00706c · Cited by 591
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Such microchannel electrodes have, for example, been implanted in nerves at locations very proximal to the dorsal root ganglia to monitor bladder function in rodents at long-term implantation time points (Chew et al., 2013).”
BackgroundBioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Metadata
- Authors
- Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., & Fawcett, J. W.
- Affiliations
- University of Cambridge (GB)
- King's College London (GB)
- University of Reading (GB)
- École Polytechnique Fédérale de Lausanne (CH)
- University College London (GB)
- Department of Medical Physics and Bioengineering, University College London, London WC1E 6BT, UK.
- Corresponding author
- Chew, Daniel J.
- Zhu, Lan
- ORCID
- Venue
- Science Translational Medicine
- Published
- 2013-11-06
- Volume
- 5
- Issue
- 210
- Pages
- 210ra155-210ra155
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2016920038
- Cited by
- 123
- References
- 56
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 9 · 2023: 7 · 2022: 6 · 2021: 10 · 2020: 12 · 2019: 14 · 2018: 14 · 2017: 12 · 2016: 12 · 2015: 9 · 2014: 10 · 2013: 1
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- DMU Open Research Archive (De Montfort University) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Portal (King's College London) (submittedVersion)
- Funders
- Christopher and Dana Reeve Foundation
- Fondation Bertarelli
- Acorda Therapeutics
- National Institute for Health and Care Research
- Novartis Pharma
- Engineering and Physical Sciences Research Council (EP/H00727X/1)
- Topics
- Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- neurogenic bladder, spinal cord injury, dorsal root stimulation, ventral root stimulation, detrusor-sphincter dyssynergia, sensory feedback, rat model
- MeSH terms
- Action Potentials, Animals, Axons, Urinary Bladder, Electric Stimulation, Female, Microelectrodes, Myelin Sheath, Nerve Block, Organ Size, Prosthesis Design, Spinal Cord Injuries, Spinal Nerve Roots, Urination, Rats, Sprague-Dawley, Implants, Experimental, Rats, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat. https://app.cochat.ai/papers/10.1126/scitranslmed.3007186
- The paper
- Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2013). A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat. Science Translational Medicine. https://doi.org/10.1126/scitranslmed.3007186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.