The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
On the feasibility of using motor imagery EEG-based brain–computer interface in chronic tetraplegics for assistive robotic arm control: a clinical test and long-term post-trial follow-up
Open accessAbstract
STUDY DESIGN: Survey and long-term clinical post-trial follow-up (interviews/correspondence) on nine chronic, post spinal cord injury (SCI) tetraplegics. OBJECTIVE: To assess feasibility of the use of Electroencephalography-based Brain-Computer Interface (EEG-BCI) for reaching/grasping assistance in tetraplegics, through a robotic arm. SETTINGS: Physical and (neuromuscular) Rehabilitation Medicine, Cardiology, Neurosurgery Clinic Divisions of TEHBA and UMPCD, in collaboration with 'Brain2Robot' (composed of the European Commission-funded Marie Curie Excellence Team by the same name, hosted by Fraunhofer Institute-FIRST), in the second part of 2008. METHODS: Enrolled patients underwent EEG-BCI preliminary training and robot control sessions. Statistics entailed multiple linear regressions and cluster analysis. A follow-up-custom questionnaire based-including patients' perception of their EEG-BCI control capacity was continued up to 14 months after initial experiments. RESULTS: EEG-BCI performance/calibration-phase classification accuracy averaged 81.0%; feedback training sessions averaged 70.5% accuracy for 7 subjects who completed at least one feedback training session; 7 (77.7%) of 9 subjects reported having felt control of the cursor; and 3 (33.3%) subjects felt that they were also controlling the robot through their movement imagination. No significant side effects occurred. BCI performance was positively correlated with beta (13-30 Hz) EEG spectral power density (coefficient 0.432, standardized coefficient 0.745, P-value=0.025); another possible influence was sensory AIS score (range: 0 min to 224 max, coefficient -0.177, standardized coefficient -0.512, P=0.089). CONCLUSION: Limited but real potential for self-assistance in chronic tetraplegics by EEG-BCI-actuated mechatronic devices was found, which was mainly related to spectral density in the beta range positively (increasing therewith) and to AIS sensory score negatively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Berridge, C. W., & Waterhouse, B. D. (2003) · Brain Research Reviews · doi:10.1016/s0165-0173(03)00143-7 · Cited by 2,529
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Brain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
Kübler, A., & Birbaumer, N. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.019 · Cited by 441
Noradrenergic modulation of arousal
Berridge, C. W. (2008) · Brain Research Reviews · doi:10.1016/j.brainresrev.2007.10.013 · Cited by 368
Physical posture: Could it have regulatory or feedback effects on motivation and emotion?
Riskind, J. H., & Gotay, C. C. (1982) · Motivation and Emotion · doi:10.1007/bf00992249 · Cited by 342
Thinking on your back: Solving anagrams faster when supine than when standing
Lipnicki, D. M., & Byrne, D. G. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2005.03.003 · Cited by 54
Cited by
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
Brain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
Neural interfaces for the brain and spinal cord—restoring motor function
Jackson, A., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 253
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Decoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
Metadata
- Authors
- Onose, G., Grozea, C., Anghelescu, A., Daia, C., Sinescu, C. J., Ciurea, A. V., Spircu, T., Mirea, A., Andone, I., Spânu, A., Popescu, C., Mihăescu, A.-S., Fazli, S., Danóczy, M., & Popescu, F.
- Venue
- Spinal Cord
- Published
- 2012-03-13
- Volume
- 50
- Issue
- 8
- Pages
- 599-608
- ISSN
- 1362-4393 (ISSN-L)
- 1476-5624
- OpenAlex
- W2053887124
- Cited by
- 168
- References
- 10
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the feasibility of using motor imagery EEG-based brain–computer interface in chronic tetraplegics for assistive robotic arm control: a clinical test and long-term post-trial follow-up. https://app.cochat.ai/papers/10.1038/sc.2012.14
- The paper
- Onose, G., Grozea, C., Anghelescu, A., Daia, C., Sinescu, C. J., Ciurea, A. V., Spircu, T., Mirea, A., Andone, I., Spânu, A., Popescu, C., Mihăescu, A.-S., Fazli, S., Danóczy, M., & Popescu, F. (2012). On the feasibility of using motor imagery EEG-based brain–computer interface in chronic tetraplegics for assistive robotic arm control: a clinical test and long-term post-trial follow-up. Spinal Cord. https://doi.org/10.1038/sc.2012.14
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.