Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Can dual energy X-ray absorptiometry provide a valid assessment of changes in thigh muscle mass with strength training in older adults?

Delmonico, M J, Kostek, M C, Johns, J, Hurley, B F, Conway, J M · 2008 · European Journal of Clinical Nutrition

Abstract

Objective To determine how dual-energy X-ray absorptiometry (DXA) compares to computed tomography (CT) for measuring changes in total thigh skeletal muscle (SM) mass with strength training (ST) in older adults.Subjects Fifty previously sedentary, relatively healthy older men (n=23, 60 (s.d.=7.5) years) and women (n=27, 60 (s.d.=9.3) years).Results Results indicate that there was a significant increase in thigh SM mass with ST measured by both CT (3.9+/-0.4%) and DXA (2.9+/-0.6%) methods (both P<0.001), and there was not a significant difference in percent change between the two methods, although there was a substantial absolute difference ( approximately 2 kg) at baseline between the two methods. Although Bland-Altman plots indicate overall agreement between the percent thigh SM mass changes of DXA vs CT methods, the 3.4% error associated with DXA was greater than the thigh SM mass change from DXA. However, the CT measured change in thigh SM mass was greater than its error (0.6%).Conclusions DXA overestimates baseline and after ST thigh SM mass, and may not be able to detect small changes in thigh SM mass with ST due to its higher error. Although DXA has certain advantages that warrant is used in epidemiologic and intervention studies, improvements to DXA are needed for the accurate assessment of small changes in thigh SM mass.

Overview

Integrity signals

Registry

Crossref · 10.1038/sj.ejcn.1602880

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Cited by

See all 93

Metadata

Authors
Delmonico, M. J., Kostek, M. C., Johns, J., Hurley, B. F., & Conway, J. M.
Affiliations
  • University of Pittsburgh (US)
  • Children's National (US)
  • University of Maryland, College Park (US)
  • Agricultural Research Service (US)
Corresponding author
Delmonico, M J
Venue
European Journal of Clinical Nutrition
Published
2007-08-08
Volume
62
Issue
12
Pages
1372-1378
ISSN
  • 0954-3007 (ISSN-L)
  • 1476-5640
OpenAlex
W2087415857
Cited by
78
References
30
Citations by year
2026: 4 · 2025: 2 · 2024: 9 · 2023: 3 · 2022: 5 · 2021: 11 · 2020: 3 · 2019: 8 · 2018: 5 · 2017: 5 · 2016: 7 · 2015: 3 · 2014: 1 · 2013: 5 · 2012: 3
FWCI
0.67
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • European Journal of Clinical Nutrition (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute on Aging (K01AG022791, AG-1620501, AG022791, 1AG-42148)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Physiology (medical) › Nutrition and Health in Aging
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
Keywords
dual-energy X-ray absorptiometry, resistance training, older adults, computed tomography, measurement agreement, sedentary older adults
MeSH terms
Aged, Aged, 80 and over, Aging, Female, Humans, Male, Middle Aged, Sensitivity and Specificity, Thigh, Weight Lifting, Reproducibility of Results, Absorptiometry, Photon, Geriatric Assessment, Tomography Scanners, X-Ray Computed, Muscle, Skeletal, Resistance Training

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can dual energy X-ray absorptiometry provide a valid assessment of changes in thigh muscle mass with strength training in older adults? https://app.cochat.ai/papers/10.1038/sj.ejcn.1602880
The paper
Delmonico, M. J., Kostek, M. C., Johns, J., Hurley, B. F., & Conway, J. M. (2008). Can dual energy X-ray absorptiometry provide a valid assessment of changes in thigh muscle mass with strength training in older adults? European Journal of Clinical Nutrition. https://doi.org/10.1038/sj.ejcn.1602880

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.