Gene therapy progress and prospects: Ultrasound for gene transfer
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled vesicle deformation and lysis by single oscillating bubbles
Marmottant, P., & Hilgenfeldt, S. (2003) · Nature · doi:10.1038/nature01613 · Cited by 853
Ultrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Vibrating microbubbles poking individual cells: Drug transfer into cells via sonoporation
van Wamel, A., Kooiman, K., Harteveld, M., Emmer, M., ten Cate, F. J., Versluis, M., & de Jong, N. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.02.007 · Cited by 595
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Plasma membrane poration induced by ultrasound exposure: Implication for drug delivery
Mehier-Humbert, S., Bettinger, T., Yan, F., & Guy, R. H. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.01.007 · Cited by 360
Self-citationUltrasound-induced cell membrane porosity
Deng, C. X., Sieling, F., Pan, H., & Cui, J. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.01.005 · Cited by 354
Lan, H. Y., Mu, W., Tomita, N., Huang, X. R., Li, J. H., Zhu, H.-J., Morishita, R., & Johnson, R. J. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000067632.04658.b8 · Cited by 344
Mechanism of intracellular delivery by acoustic cavitation
Schlicher, R. K., Radhakrishna, H., Tolentino, T. P., Apkarian, R. P., Zarnitsyn, V., & Prausnitz, M. R. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.02.1416 · Cited by 327
Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V. (2003) · Circulation · doi:10.1161/01.cir.0000084535.35435.ae · Cited by 321
Cited by
Non-viral vectors for gene-based therapy
Yin, H., Kanasty, R. L., Eltoukhy, A. A., Vegas, A. J., Dorkin, J. R., & Anderson, D. G. (2014) · Nature Reviews Genetics · doi:10.1038/nrg3763 · Cited by 3,123
Qian, X., Zheng, Y., & Chen, Y. (2016) · Advanced Materials · doi:10.1002/adma.201602012 · Cited by 882
Non Viral Vectors in Gene Therapy- An Overview
Ramamoorth, M. (2015) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2015/10443.5394 · Cited by 761
Meijering, B. D. M., Juffermans, L. J. M., van Wamel, A., Henning, R. H., Zuhorn, I. S., Emmer, M., Versteilen, A. M. G., Paulus, W. J., van Gilst, W. H., Kooiman, K., et al. (2009) · Circulation Research · doi:10.1161/circresaha.108.183806 · Cited by 483
HIF-1α-BNIP3-mediated mitophagy in tubular cells protects against renal ischemia/reperfusion injury
Fu, Z.-J., Wang, Z.-Y., Xu, L., Chen, X.-H., Li, X.-X., Liao, W.-T., Ma, H.-K., Jiang, M.-D., Xu, T.-T., Xu, J., et al. (2020) · Redox Biology · doi:10.1016/j.redox.2020.101671 · Cited by 382
“This technique has been shown to effectively deliver DNA into the renal cells without toxicity to the kidney [31].”
BackgroundLiposomes in ultrasonic drug and gene delivery
Huang, S.-L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.003 · Cited by 339
Drug loaded microbubble design for ultrasound triggered delivery
Lentacker, I., De Smedt, S. C., & Sanders, N. N. (2009) · Soft Matter · doi:10.1039/b823051j · Cited by 264
Spatiotemporally controlled single cell sonoporation
Fan, Z., Liu, H., Mayer, M., & Deng, C. X. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1208198109 · Cited by 246
Stimulation of bone repair with ultrasound: A review of the possible mechanic effects
Padilla, F., Puts, R., Vico, L., & Raum, K. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.01.004 · Cited by 234
“DNA delivery into various cells in vitro and in vivo has also been reported [35], demonstrating increased gene expression, even if optimization is still required to achieve high transfection rates [36].”
BackgroundAcoustofluidic centrifuge for nanoparticle enrichment and separation
Gu, Y., Chen, C., Mao, Z., Bachman, H., Becker, R., Rufo, J., Wang, Z., Zhang, P., Mai, J., Yang, S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abc0467 · Cited by 227
Cancer gene therapy by IL-12 gene delivery using liposomal bubbles and tumoral ultrasound exposure
Suzuki, R., Namai, E., Oda, Y., Nishiie, N., Otake, S., Koshima, R., Hirata, K., Taira, Y., Utoguchi, N., Negishi, Y., et al. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.027 · Cited by 207
Sonoporation: Mechanistic insights and ongoing challenges for gene transfer
Delalande, A., Kotopoulis, S., Postema, M., Midoux, P., & Pichon, C. (2013) · Gene · doi:10.1016/j.gene.2013.03.095 · Cited by 200
“As a consequence, the level of gene expression is still not as much as expected even though it is sometimes 1 or 2 orders of magnitude higher than the level obtained with plasmid DNA alone (Newman and Bettinger, 2007; Pichon et al., 2008).”
BackgroundQiu, Y., Luo, Y., Zhang, Y., Cui, W., Zhang, D., Wu, J., Zhang, J., & Tu, J. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.04.010 · Cited by 198
Controlled permeation of cell membrane by single bubble acoustic cavitation
Zhou, Y., Yang, K., Cui, J., Ye, J. Y., & Deng, C. X. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.09.068 · Cited by 194
“However, the technique has been limited by its variable delivery outcome and relatively low delivery efficiency [16,18,21-24].”
BackgroundPortet, T., & Dimova, R. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.09.032 · Cited by 181
Intracellular delivery and calcium transients generated in sonoporation facilitated by microbubbles
Fan, Z., Kumon, R. E., Park, J., & Deng, C. X. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.09.031 · Cited by 167
“Because ultrasound exposure can be non-invasively controlled in application volume and location as well as exposure duration, sonoporation is uniquely suitable for in vivo site-specific delivery [14,15].”
BackgroundSonoporation, drug delivery, and gene therapy
Liang, H.-D., Tang, J., & Halliwell, M. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim565 · Cited by 166
Geers, B., Lentacker, I., Sanders, N. N., Demeester, J., Meairs, S., & De Smedt, S. C. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.02.024 · Cited by 159
“Inertial cavitation on the other hand occurs at higher acoustical pressures, the movement of the microbubbles becomes more violent which leads to destruction of the microbubbles [4].”
BackgroundNaik, S., Shreya, A. B., Raychaudhuri, R., Pandey, A., Lewis, S. A., Hazarika, M., Bhandary, S. V., Rao, B. S. S., & Mutalik, S. (2021) · Life Sciences · doi:10.1016/j.lfs.2020.118712 · Cited by 33
Metadata
- Authors
- Newman, C. M. H., & Bettinger, T.
- Venue
- Gene Therapy
- Published
- 2007-03-01
- Volume
- 14
- Issue
- 6
- Pages
- 465-475
- ISSN
- 0969-7128 (ISSN-L)
- 1476-5462
- OpenAlex
- W2054332277
- Cited by
- 392
- References
- 42
- FWCI
- 20.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.