The DOI matches its Crossref record.
Ultrasound-Targeted Microbubble Destruction Can Repeatedly Direct Highly Specific Plasmid Expression to the Heart
Open accessAbstract
Background— Noninvasive, tissue-specific delivery of therapeutic agents would be a valuable clinical tool. We have previously shown that ultrasound-targeted microbubble destruction can direct expression of an adenoviral reporter to the heart. The present study shows that this method can be applied to selectively deliver plasmid vectors to the heart. Methods and Results— We used albumin and lipid microbubbles containing plasmids with a luciferase transgene to target the heart in rats. After 4 days, organs were harvested and analyzed for reporter gene expression. In a second set of experiments, the hearts of rats treated with plasmids were harvested at various time points during a 4-week period. Both luciferase activity and mRNA concentrations were measured. Luciferase transfection with plasmids showed highly specific gene expression in the heart, with hardly any activity in control organs. Time course evaluation showed high transgene expression in the first 4 days, with a rapid decline thereafter. Repeated treatment produced a second peak of transgene expression with similar decay. Conclusions— Ultrasound-mediated destruction of microbubbles directs plasmid transgene expression to the heart with much greater specificity than viral vectors and can be regulated by repeated treatments. This noninvasive technique is a promising method for cardiac gene therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Porter, T. R., Mulvagh, S. L., Abdelmoneim, S. S., Becher, H., Belcik, J. T., Bierig, M., Choy, J., Gaibazzi, N., Gillam, L. D., Janardhanan, R., et al. (2018) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.11.013 · Cited by 432
Microbubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Pleger, S. T., Shan, C., Ksienzyk, J., Bekeredjian, R., Boekstegers, P., Hinkel, R., Schinkel, S., Leuchs, B., Ludwig, J., Qiu, G., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002097 · Cited by 234
Self-citation
Metadata
- Authors
- Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V.
- Venue
- Circulation
- Published
- 2003-08-26
- Volume
- 108
- Issue
- 8
- Pages
- 1022-1026
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2099781987
- Cited by
- 321
- References
- 0
- FWCI
- 15.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-Targeted Microbubble Destruction Can Repeatedly Direct Highly Specific Plasmid Expression to the Heart. https://app.cochat.ai/papers/10.1161/01.cir.0000084535.35435.ae
- The paper
- Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V. (2003). Ultrasound-Targeted Microbubble Destruction Can Repeatedly Direct Highly Specific Plasmid Expression to the Heart. Circulation. https://doi.org/10.1161/01.cir.0000084535.35435.ae
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.