The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multiphoton Imaging of Ultrasound/Optison Mediated Cerebrovascular Effects in vivo
Abstract
Ultrasound (US) enhanced with microbubble contrast agents may transiently disrupt the blood–brain barrier (BBB) with minimal damage, providing a technique for noninvasive, localized drug-delivery deep within the brain. The mechanism and temporal profile of disruption are not understood, owing to the limitations of imaging modalities used previously. In this study, we monitored US-induced BBB disruption with multiphoton microscopy, providing high-resolution temporal and spatial information about the permeabilization mechanism and immediate effects of US exposure. Anesthetized C57 mice were prepared with a craniotomy and injected intravenously with fluorescent dyes to permit visualization of the vasculature and BBB integrity. The animals were imaged through a cranial window while exposed to low-intensity US ( f =1.029 MHz, power = 0.2 W) with a coincident intravenous injection of Optison (a microbubble contrast agent). We observed arteriolar vasoconstriction on US exposure that disrupted blood flow and lasted up to 5 mins; BBB disruption occurred via two characteristically distinct processes—perivascular fluorescence gradually increased (over minutes) along the length of the affected vessel without apparent rupture of the vessel wall or rapidly (seconds) increased in select, focal regions. These data corroborated previous studies suggesting increased endothelial transcytosis and breached tight junctions and demonstrated vasoconstriction, which might alter BBB permeability by modifying cerebral blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Self-citation
Cited by
Spreading Depression, Spreading Depolarizations, and the Cerebral Vasculature
Ayata, C., & Lauritzen, M. (2015) · Physiological Reviews · doi:10.1152/physrev.00027.2014 · Cited by 555
Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498
Disrupting the blood–brain barrier by focused ultrasound induces sterile inflammation
Kovacs, Z. I., Kim, S., Jikaria, N., Qureshi, F., Milo, B., Lewis, B. K., Bresler, M., Burks, S. R., & Frank, J. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1614777114 · Cited by 458
Aryal, M., Arvanitis, C. D., Alexander, P. M., & McDannold, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.01.008 · Cited by 443
Evolving Drug Delivery Strategies to Overcome the Blood Brain Barrier
S. Hersh, D., S. Wadajkar, A., B. Roberts, N., G. Perez, J., P. Connolly, N., Frenkel, V., A. Winkles, J., F. Woodworth, G., & J. Kim, A. (2016) · Current Pharmaceutical Design · doi:10.2174/1381612822666151221150733 · Cited by 387
Metadata
- Authors
- Raymond, S. B., Skoch, J., Hynynen, K., & Bacskai, B. J.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2007-02
- Volume
- 27
- Issue
- 2
- Pages
- 393-403
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2074120886
- Cited by
- 174
- References
- 1
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiphoton Imaging of Ultrasound/Optison Mediated Cerebrovascular Effects in vivo. https://app.cochat.ai/papers/10.1038/sj.jcbfm.9600336
- The paper
- Raymond, S. B., Skoch, J., Hynynen, K., & Bacskai, B. J. (2007). Multiphoton Imaging of Ultrasound/Optison Mediated Cerebrovascular Effects in vivo. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/sj.jcbfm.9600336
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.