The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
The DOI matches its Crossref record.
Abstract
Aim Sphygmocardiography via applanation tonometry is a non-invasive, bedside technology which utilises tonometric analysis of the radial artery pulse wave and measurement of peripheral arterial blood pressure (BP) to derive a central arterial pulse wave, central arterial BP and related indices. The present study was designed to determine: (1) the inter-operator variability in measurements obtained using this technique; (2) the relationship between measured peripheral arterial BP and derived central arterial BP.Method Multiple measurements were made from 25 healthy subjects (15 male), mean age 33 (s.d. 10.3) years, mean arterial BP 90 (s.d. 12) mm Hg by two trained observers at the same time of day on three separate occasions.Results The mean inter-operator difference was 0.1 (s.d. 1.7) mm Hg for derived systolic aortic BP and 0.1 (s.d. 0.7) mm Hg for derived diastolic aortic BP (Bland and Altman analysis). Pulse wave Augmentation Index (AIx) values, ranged from -22% to +40%, with the inter-operator measurement difference being only 0.4 (s.d. 6.4)%. Buckberg ratio measurements ranged from 119% to 254%, with the inter-operator measurement difference being only 2.7 (s.d. 15.4)%. The relationship between derived central systolic BP and peripheral systolic BP readings in individual patients was not constant and showed significant variance when compared on different days (ANOVA, P = 0.03). This was not explained by any significant variance in heart rate (ANOVA, P = 0.39).Conclusion Applanation tonometry has excellent inter-observer reproducibility when used by trained observers. Moreover, the inconsistency in the relationship between peripheral and central aortic BP suggests that the former is not a perfect surrogate for the latter. Further prospective studies are required to define whether derived central aortic BP may be a better predictor of cardiovascular morbidity and mortality and the impact of different antihypertensive therapies on the relationship between peripheral and central arterial BP.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The validity of the derived AI% has been confirmed by simultaneous direct central aortic measurements and is highly reproducible in both healthy and diseased populations. 25,26”
From Acute Effect of Caffeine on Arterial Stiffness and Aortic Pressure Waveform (2001) · cites this paper as [26]
Citations
Cites
Still being checked.
Cited by
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Self-citationO'Rourke, M. F., Pauca, A., & Jiang, X. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01400.x · Cited by 640
Avolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134379 · Cited by 521
Effect of Smoking on Arterial Stiffness and Pulse Pressure Amplification
Mahmud, A., & Feely, J. (2003) · Hypertension · doi:10.1161/01.hyp.0000047464.66901.60 · Cited by 436
A new oscillometric method for pulse wave analysis: comparison with a common tonometric method
Wassertheurer, S., Kropf, J., Weber, T., van der Giet, M., Baulmann, J., Ammer, M., Hametner, B., Mayer, C. C., Eber, B., & Magometschnigg, D. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.27 · Cited by 363
Metadata
- Authors
- Siebenhofer, A., Kemp, C., Sutton, A., & Williams, B.
- Affiliations
- University of Leicester (GB)
- Venue
- Journal of Human Hypertension
- Published
- 1999-09-01
- Volume
- 13
- Issue
- 9
- Pages
- 625-629
- ISSN
- 0950-9240 (ISSN-L)
- 1476-5527
- OpenAlex
- W2074594580
- Cited by
- 149
- References
- 0
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 6 · 2019: 2 · 2018: 4 · 2017: 4 · 2016: 4 · 2015: 7 · 2014: 8 · 2013: 10 · 2012: 6
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Journal of Human Hypertension (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Leicester Research Archive (University of Leicester) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- applanation tonometry, central blood pressure, inter-operator reproducibility, pulse wave analysis, augmentation index, measurement agreement
- MeSH terms
- Adult, Analysis of Variance, Blood Pressure, Blood Pressure Determination, Female, Humans, Male, Reference Values, Sensitivity and Specificity, Tonometry, Ocular, Reproducibility of Results, Sphygmomanometers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography. https://app.cochat.ai/papers/10.1038/sj.jhh.1000887
- The paper
- Siebenhofer, A., Kemp, C., Sutton, A., & Williams, B. (1999). The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography. Journal of Human Hypertension. https://doi.org/10.1038/sj.jhh.1000887
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.