CoChat

The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography

Siebenhofer, A, Kemp, CRW, Sutton, AJ, Williams, B · 1999 · Journal of Human Hypertension

The DOI matches its Crossref record.

Abstract

Aim Sphygmocardiography via applanation tonometry is a non-invasive, bedside technology which utilises tonometric analysis of the radial artery pulse wave and measurement of peripheral arterial blood pressure (BP) to derive a central arterial pulse wave, central arterial BP and related indices. The present study was designed to determine: (1) the inter-operator variability in measurements obtained using this technique; (2) the relationship between measured peripheral arterial BP and derived central arterial BP.Method Multiple measurements were made from 25 healthy subjects (15 male), mean age 33 (s.d. 10.3) years, mean arterial BP 90 (s.d. 12) mm Hg by two trained observers at the same time of day on three separate occasions.Results The mean inter-operator difference was 0.1 (s.d. 1.7) mm Hg for derived systolic aortic BP and 0.1 (s.d. 0.7) mm Hg for derived diastolic aortic BP (Bland and Altman analysis). Pulse wave Augmentation Index (AIx) values, ranged from -22% to +40%, with the inter-operator measurement difference being only 0.4 (s.d. 6.4)%. Buckberg ratio measurements ranged from 119% to 254%, with the inter-operator measurement difference being only 2.7 (s.d. 15.4)%. The relationship between derived central systolic BP and peripheral systolic BP readings in individual patients was not constant and showed significant variance when compared on different days (ANOVA, P = 0.03). This was not explained by any significant variance in heart rate (ANOVA, P = 0.39).Conclusion Applanation tonometry has excellent inter-observer reproducibility when used by trained observers. Moreover, the inconsistency in the relationship between peripheral and central aortic BP suggests that the former is not a perfect surrogate for the latter. Further prospective studies are required to define whether derived central aortic BP may be a better predictor of cardiovascular morbidity and mortality and the impact of different antihypertensive therapies on the relationship between peripheral and central arterial BP.

Overview

Integrity signals

Registry

Crossref · 10.1038/sj.jhh.1000887

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 165

Metadata

Authors
Siebenhofer, A., Kemp, C., Sutton, A., & Williams, B.
Affiliations
University of Leicester (GB)
Venue
Journal of Human Hypertension
Published
1999-09-01
Volume
13
Issue
9
Pages
625-629
ISSN
  • 0950-9240 (ISSN-L)
  • 1476-5527
OpenAlex
W2074594580
Cited by
149
References
0
Citations by year
2025: 2 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 6 · 2019: 2 · 2018: 4 · 2017: 4 · 2016: 4 · 2015: 7 · 2014: 8 · 2013: 10 · 2012: 6
FWCI
5.55
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Journal of Human Hypertension (publishedVersion)
  • PubMed (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • Leicester Research Archive (University of Leicester) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
Keywords
applanation tonometry, central blood pressure, inter-operator reproducibility, pulse wave analysis, augmentation index, measurement agreement
MeSH terms
Adult, Analysis of Variance, Blood Pressure, Blood Pressure Determination, Female, Humans, Male, Reference Values, Sensitivity and Specificity, Tonometry, Ocular, Reproducibility of Results, Sphygmomanometers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography. https://app.cochat.ai/papers/10.1038/sj.jhh.1000887
The paper
Siebenhofer, A., Kemp, C., Sutton, A., & Williams, B. (1999). The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography. Journal of Human Hypertension. https://doi.org/10.1038/sj.jhh.1000887

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.