The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients
Open accessAbstract
Using interdialytic ambulatory blood pressure (BP) recordings as the reference standard, we compared the performance of routine, standardized and home BP monitoring in 104 predominantly black patients on chronic hemodialysis for at least 3 months. Dialysis unit BP recordings were averaged over 2 weeks and home BP over 1 week. Awake ambulatory BP of > or =135 mmHg systolic or > or =85 mmHg diastolic was taken as evidence of hypertension. Average awake ambulatory BP was 128.1+/-21.6/73.5+/-13.5 mmHg, home BP 141.3+/-21.9/78.7+/-11.9 mmHg, standardized pre-dialysis BP 141.7+/-22.6/74.2+/-13.5 mmHg and post-dialysis 119.9+/-20.5/69.1+/-13.1 mmHg, routine pre-dialysis 145.4+/-21.8/79.0+/-13.1 mmHg and post-dialysis 131.5+/-19.2/72.5+/-11.4 mmHg. Sixty-three percent of the patients had well-controlled BP by ambulatory BP monitoring and isolated diastolic hypertension was rare (3%). The standard deviation of the differences between ambulatory and routine pre-dialysis BP was 17.6 mmHg, routine post-dialysis was 16.1 mmHg, standardized pre-dialysis was 16.4 mmHg, standardized post-dialysis was 14.1 mmHg, and home BP was 14.2 mmHg. The area under receiver operating characteristic curves was similar for home and standardized BP but lower for routine BP. Home systolic BP of > or =150 mmHg averaged over 1 week had the best combination of sensitivity (80%) and specificity (84.1%) in diagnosing systolic hypertension--present in 94% of the hypertensive dialysis patients. Home BP monitoring is similar to standardized recording of BP in hemodialysis patients. A systolic BP threshold of 150 mmHg at home averaged over 1 week serves as a useful predictor of hypertension diagnosed by ambulatory BP monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Patients with CKD on haemodialysis are profoundly different from patients with CKD who are not on dialysis; this is so because of varying states of volume excess among patients and volume accumulation in the interdialytic period [204–206].”
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
ZWEIG, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,595
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440420033005 · Cited by 3,777
“U” curve association of blood pressure and mortality in hemodialysis patients
Zager, P. G., Nikolic, J., Brown, R. H., Campbell, M. A., Hunt, W. C., Peterson, D., Stone, J. V., Levey, A. S., Meyer, K. B., Klag, M. J., et al. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00005.x · Cited by 659
Agarwal, R., Nissenson, A. R., BATLLE, D. C., Coyne, D. W., Trout, J. R., & Warnock, D. G. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00366-8 · Cited by 480
Self-citationPort, F. K., Hulbert‐Shearon, T. E., Wolfe, R. A., Bloembergen, W. E., Golper, T. A., Agodoa, L. Y. C., & Young, E. W. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70188-5 · Cited by 448
What is the value of home blood pressure measurement in patients with mild hypertension?
Kleinert, H. D., Harshfield, G. A., Pickering, T. G., Devereux, R. B., Sullivan, P. A., Marion, R., Mallory, W. K., & LARAGH, J. H. (1984) · Hypertension · doi:10.1161/01.hyp.6.4.574 · Cited by 295
Black, H. R., Jd, C., Kaplan, N. M., Kc, F., Av, C., Dustan, H. P., Rw, G., Moser, M., Sheps, S. G., Agodoa, L. Y. C., et al. (1997) · Cited by 244
Amar, J., Vernier, I., Rossignol, E., Bongard, V., Arnaud, C., Conté, J. J., Salvador, M., & Chamontin, B. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00107.x · Cited by 227
Hypertension and survival in chronic hemodialysis patients—Past lessons and future opportunities
Agarwal, R. (2004) · Kidney International · doi:10.1111/j.1523-1755.2005.00050.x · Cited by 185
Self-citationHome Blood Pressure Monitoring in CKD
Andersen, M. J., Khawandi, W., & Agarwal, R. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.02.015 · Cited by 123
Self-citationPrediction of hypertension in chronic hemodialysis patients
Agarwal, R., & Lewis, R. R. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00997.x · Cited by 108
Self-citationA comparison of standardized versus “usual” blood pressure measurements in hemodialysis patients
Rahman, M., Griffin, V., Kumar, A., Manzoor, F., Wright, J. T., & Smith, M. C. F. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.33395 · Cited by 102
Supervised atenolol therapy in the management of hemodialysis hypertension
Agarwal, R. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00359.x · Cited by 99
Self-citationReproducibility of ambulatory blood pressure monitoring in hemodialysis patients
Peixoto, A. J., Santos, S. F. F., Mendes, R. B., Crowley, S. T., Maldonado, R. A., Orías, M., Mansoor, G. A., & White, W. B. (2000) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2000.19100 · Cited by 98
What is hypertension in chronic haemodialysis? The role of interdialytic blood pressure monitoring
Mitra, S., Chandna, S. M., & Farrington, K. (1999) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/14.12.2915 · Cited by 68
Role of home blood pressure monitoring in hemodialysis patients
Agarwal, R. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70219-2 · Cited by 62
Self-citationEditorials: Assessment of Blood Pressure in Hemodialysis Patients
Agarwal, R. (2002) · Seminars in Dialysis · doi:10.1046/j.1525-139x.2002.00074.x · Cited by 48
Self-citationSystolic Hypertension in Hemodialysis Patients
Agarwal, R. (2003) · Seminars in Dialysis · doi:10.1046/j.1525-139x.2003.16041.x · Cited by 42
Self-citationDelayed Hypotensive Response to Dialysis in Hypertensive Patients with End-Stage Renal Disease
BATLLE, D. C., von Riotte, A., & Lang, G. R. (2008) · American Journal of Nephrology · doi:10.1159/000167047 · Cited by 33
Hypertension in end-stage renal disease patients
Zager, P. G., Nikolic, J., Raj, D. S., Tzamaloukas, A. H., & Campbell, M. A. (2000) · Current Opinion in Nephrology & Hypertension · doi:10.1097/00041552-200005000-00012 · Cited by 5
A practical method to statistically classify devices according to their relative accuracy
Minini, P., Gaspoz, J., Pichot, V., Costes, F., Roche, F., Lacour, J. R., Antoniadis, A., & Barthélemy, J. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00320.x · Cited by 3
Flagged first, then by citations
Cited by
Sorted by citations
Call to Action on Use and Reimbursement for Home Blood Pressure Monitoring
Pickering, T. G., Miller, N. H., Ogedegbe, G. G., Krakoff, L. R., Artinian, N. T., & Goff, D. C. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 666
Cardiac Disease Evaluation and Management Among Kidney and Liver Transplantation Candidates
Lentine, K. L., Costa, S. P., Weir, M. R., Robb, J. F., Fleisher, L. A., Kasiske, B. L., Carithers, R. L., Ragosta, M., Bolton, K., Auerbach, A. D., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.008 · Cited by 398
Cardiac Disease Evaluation and Management Among Kidney and Liver Transplantation Candidates
Lentine, K. L., Costa, S. P., Weir, M. R., Robb, J. F., Fleisher, L. A., Kasiske, B. L., Carithers, R. L., Ragosta, M., Bolton, K., Auerbach, A. D., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823eb07a · Cited by 322
Flythe, J. E., Chang, T. I., Gallagher, M., Lindley, E. J., Madero, M., Sarafidis, P. A., Unruh, M. L., Wang, A. Y.-M., Weiner, D. E., Cheung, M., et al. (2020) · Kidney International · doi:10.1016/j.kint.2020.01.046 · Cited by 304
Blood Pressure and Mortality Among Hemodialysis Patients
Agarwal, R. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.144899 · Cited by 274
Self-citation
Metadata
- Authors
- Agarwal, R., Andersen, M. J., Bishu, K., & Saha, C.
- Affiliations
- Richard L. Roudebush VA Medical Center (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Agarwal, R.
- ORCID
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2006-03
- Volume
- 69
- Issue
- 5
- Pages
- 900-906
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W1963876316
- Cited by
- 175
- References
- 24
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 5 · 2023: 10 · 2022: 8 · 2021: 7 · 2020: 8 · 2019: 9 · 2018: 5 · 2017: 7 · 2016: 12 · 2015: 7 · 2014: 7 · 2013: 7 · 2012: 14
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Kidney International (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dialysis Clinics
- National Institutes of Health (5t32dk062711-05)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK062030, 5T32DK062711-02)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Nephrology › Dialysis and Renal Disease Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- home blood pressure monitoring, hypertension diagnosis, hemodialysis patients, ambulatory blood pressure monitoring, systolic hypertension, isolated diastolic hypertension, blood pressure thresholds, Black patients
- MeSH terms
- Adult, Aged, Blood Pressure Determination, Female, Renal Dialysis, Humans, Hypertension, Male, Middle Aged, Sensitivity and Specificity, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›