Green Fluorescent Protein is a Suitable Reporter of Tumor Hypoxia Despite an Oxygen Requirement for Chromophore Formation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The oxygen requirement for chromophore formation potentially limits the use of green fluorescent protein as a reporter under hypoxic conditions. In the light of this, the applicability of a hypoxia-responsive enhanced green fluorescent protein (EGFP)-based system to the measurement of tumor hypoxia was tested in human HT 1080 fibrosarcoma cells stably transfected with a destabilized EGFP vector containing the hypoxia-responsive 5HRE-hCMVmp promoter or, as a positive control, the strong constitutive CMV promoter. After various schedules of hypoxia and reoxygenation, EGFP fluorescence of live cells was assessed by flow cytometry, and protein levels were analyzed by Western blot. Fluorescence of CMV promoter positive control cells dropped to 38+/-5% of aerobic levels after 12 hours at <0.02% oxygen, but was unaffected by higher oxygen concentrations. Following 12 hours at <0.02% oxygen, cells transfected with the hypoxia-responsive vector exhibited maximum fluorescence after 4 hours of subsequent reoxygenation, reaching 68+/-2% of the levels in CMV promoter controls under aerobic conditions. With such reoxygenation, these cells exhibited a constant increase in fluorescence between 2% and <0.02% oxygen. EGFP chromophore formation is only affected by near-anoxic oxygen concentrations. The correlation of fluorescence and oxygen concentration is restored by a 4-hour reoxygenation period due to oxidation of pre-synthesized EGFP and a delayed increase in EGFP protein synthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regulation of Mammalian O 2 Homeostasis by Hypoxia-Inducible Factor 1
Semenza, G. L. (1999) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.15.1.551 · Cited by 1,914 · cited 1×
“Firstly, the fact that the transcription factor subunit HIF - 1, which has been found to be mainly responsible for the regulation of the hypoxic response, including the expression of angiogenic and glycolytic enzymes [24, 25 ], directly activates the HREs in the system now studied underscores the biological relevance…”
BackgroundJiang, B. H., Semenza, G. L., Bauer, C., & Marti, H. H. (1996) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1996.271.4.c1172 · Cited by 1,213 · cited 1×
“HIF -1 protein levels increased modestly between 6% and 2%, but drastically below 2% O2 in HeLa S3 cells [ 26 ]. Whereas EGFP protein levels in 5HRE- hCMVmp- d2EGFP–transfected cells after 12 hours at 26 ], the detection of EGFP fluorescence seems to be less sensitive, not detecting increased EGFP levels at 6% or 2% o…”
BackgroundNordsmark, M., Overgaard, M., & Overgaard, J. (1996) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(96)91811-3 · Cited by 942
Cited by
Radiation activates HIF-1 to regulate vascular radiosensitivity in tumors
Moeller, B. J., Cao, Y., Li, C. Y., & Dewhirst, M. W. (2004) · Cancer Cell · doi:10.1016/s1535-6108(04)00115-1 · Cited by 996
Krohn, K. A., Link, J. M., & Mason, R. P. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045914 · Cited by 506
“Some elegant methods have been developed to directly measure HIF-1 activity by the introduction of transgenes with hypoxic response elements as promoter sequences coupled to reporter genes such as luciferase (207,208) or green fluorescent protein, GFP (209).”
MethodSorg, B. S., Moeller, B. J., Donovan, O., Cao, Y., & Dewhirst, M. W. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2003369 · Cited by 306
Fate-mapping post-hypoxic tumor cells reveals a ROS-resistant phenotype that promotes metastasis
Godet, I., Shin, Y. J., Ju, J. A., Ye, I. C., Wang, G., & Gilkes, D. M. (2019) · Nature Communications · doi:10.1038/s41467-019-12412-1 · Cited by 273
It's not just about anatomy: In vivo bioluminescence imaging as an eyepiece into biology
Contag, C. H., & Ross, B. D. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10178 · Cited by 256
Metadata
- Authors
- Vordermark, D., Shibata, T., & Brown, J. M.
- Venue
- Neoplasia
- Publisher
- Elsevier BV
- Published
- 2001
- Volume
- 3
- Issue
- 6
- Pages
- 527-534
- ISSN
- 1476-5586 (ISSN-L)
- OpenAlex
- W2086531807
- Cited by
- 110
- References
- 3
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Green Fluorescent Protein is a Suitable Reporter of Tumor Hypoxia Despite an Oxygen Requirement for Chromophore Formation. https://app.cochat.ai/papers/10.1038/sj.neo.7900192
- The paper
- Vordermark, D., Shibata, T., & Brown, J. M. (2001). Green Fluorescent Protein is a Suitable Reporter of Tumor Hypoxia Despite an Oxygen Requirement for Chromophore Formation. Neoplasia. https://doi.org/10.1038/sj.neo.7900192
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.