CoChat

Electrical stimulation of abdominal muscles for control of blood pressure and augmentation of cough in a C3/4 level tetraplegic

Taylor, PN, Tromans, AM, Harris, KR, Swain, ID · 2002 · Spinal Cord

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Objectives Evaluation of a FES (Functional Electrical Stimulation) device for the relief of postural hypertension and augmentation of cough in a C3 ventilator-dependent tetraplegic. Study design A single case study. Setting A supra regional spinal unit in the UK. Method A dual channel stimulator was designed that allowed selection and initiation of two predetermined stimulation intensities using a chin controlled joystick. Two sets of 70 mm diameter electrodes were placed either side of the abdomen. Approximately 80 mA, 300 micros, 40 Hz was required for assisted cough while about 40 mA was required for maintenance of blood pressure. After eating, the lower level stimulus is self-administered every 3 to 5 min gradually increasing the time between groups of burst to once every hour after 90 min. Results Following eating, a blood pressure of 60/45 mmHg was recorded. After five 1 s bursts of stimulation in quick repetition, this was increased to 133/92 mmHg. After 2 min blood pressure had fallen to 124/86 mmHg and to 93/66 after a further 4 min. The electrical stimulation was then repeated, returning the blood pressure to the previous higher level. Measurement of peak expiratory flow showed an increase from 275 l/min for an unassisted cough to 425 l/min when using the device. Conclusion The device is used every day. The user is now independent in coughing function and no longer requires suction or manual assistance. Maintenance of blood pressure has significantly improved his qu…

Overview

Integrity signals

Registry

Crossref · 10.1038/sj.sc.3101250

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 3

  1. Linder SH . Functional Electrical Stimulation to enhance cough in spinal cord injury Chest 1993 103: 166–169 · DOI
  2. Taylor PN et al.. Correction of Dropped Foot using the Odstock 2 Channel Stimulator (O2CHS). 4th annual IFESS conference 1999 257-260 ISBN 4-9980783-0-5
  3. Kewalramani LS . Autonomic dysreflexia in tramuatic myelopathy Am J Phys Med 1980 59: 1–21

Cited by

See all 38

Metadata

Authors
Taylor, P., Tromans, A., Harris, K., & Swain, I.
Affiliations
Salisbury District Hospital (GB)
Venue
Spinal Cord
Published
2002-01
Volume
40
Issue
1
Pages
34-36
ISSN
  • 1362-4393 (ISSN-L)
  • 1476-5624
OpenAlex
W1997117410
Cited by
38
References
10
Citations by year
2026: 1 · 2024: 1 · 2022: 1 · 2020: 2 · 2018: 1 · 2017: 3 · 2015: 1 · 2014: 4 · 2012: 1
FWCI
0.85
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Spinal Cord (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
Keywords
functional electrical stimulation, tetraplegia, blood pressure control, cough augmentation, ventilator dependence, peak expiratory flow, assistive device design
MeSH terms
Abdominal Muscles, Adult, Cervical Vertebrae, Cough, Electric Stimulation, Humans, Hypotension, Orthostatic, Male, Quadriplegia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.