Quantitative, spectrally-resolved intraoperative fluorescence imaging
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the first time. Moreover, we present images from human surgery which detect residual tumor not evident with state-of-the-art vFI. The wide-field qFI technique has broad implications for intraoperative surgical guidance because it provides near real-time quantitative assessment of multiple fluorescent biomarkers across the operative field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fisher, B., Anderson, S., Bryant, J., Margolese, R. G., Deutsch, M., Fisher, E. R., Jeong, J.-H., & Wolmark, N. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa022152 · Cited by 6,249 · cited 2×
“A total of nine (9) phantoms of three (3) different optical absorption (ma,x 5 20, 40, and 60 cm(21)) and scattering values (m’s,m 5 8.”
BackgroundStummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Cited by
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Intraoperative brain cancer detection with Raman spectroscopy in humans
Jermyn, M., Mok, K., Mercier, J., Desroches, J., Pichette, J., Saint-Arnaud, K., Bernstein, L., Guiot, M.-C., Petrecca, K., & Leblond, F. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2384 · Cited by 618
Self-citationVisualization technologies for 5-ALA-based fluorescence-guided surgeries
Wei, L., Roberts, D. W., Sanai, N., & Liu, J. T. C. (2019) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-03077-9 · Cited by 67
Self-citationBravo, J. J., Olson, J. D., Davis, S. C., Roberts, D. W., Paulsen, K. D., & Kanick, S. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-09727-8 · Cited by 53
Self-citationQuantitative Modulation of PpIX Fluorescence and Improved Glioma Visualization
Reinert, M., Piffaretti, D., Wilzbach, M., Hauger, C., Guckler, R., Marchi, F., & D'Angelo, M. L. (2019) · Frontiers in Surgery · doi:10.3389/fsurg.2019.00041 · Cited by 22
“Calibration For calibrating the system, tissue phantoms with defined optical properties were created to mimic brain tissue (19).”
Method
Metadata
- Authors
- Valdés, P. A., Leblond, F., Jacobs, V. L., Wilson, B. C., Paulsen, K. D., & Roberts, D. W.
- Venue
- Scientific Reports
- Published
- 2012-11-12
- Volume
- 2
- Issue
- 1
- Pages
- 798-798
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2039455773
- Cited by
- 130
- References
- 3
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative, spectrally-resolved intraoperative fluorescence imaging. https://app.cochat.ai/papers/10.1038/srep00798
- The paper
- Valdés, P. A., Leblond, F., Jacobs, V. L., Wilson, B. C., Paulsen, K. D., & Roberts, D. W. (2012). Quantitative, spectrally-resolved intraoperative fluorescence imaging. Scientific Reports. https://doi.org/10.1038/srep00798
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.