Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Superconducting nanowire single-photon detectors are an ideal match for integrated quantum photonic circuits due to their high detection efficiency for telecom wavelength photons. Quantum optical technology also requires single-photon detection with low dark count rate and high timing accuracy. Here we present very low noise superconducting nanowire single-photon detectors based on NbTiN thin films patterned directly on top of Si3N4 waveguides. We systematically investigate a large variety of detector designs and characterize their detection noise performance. Milli-Hz dark count rates are demonstrated over the entire operating range of the nanowire detectors which also feature low timing jitter. The ultra-low dark count rate, in combination with the high detection efficiency inherent to our travelling wave detector geometry, gives rise to a measured noise equivalent power at the 10(-20) W/Hz(1/2) level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
A scheme for efficient quantum computation with linear optics
Knill, E., Laflamme, R., & Milburn, G. J. (2001) · Nature · doi:10.1038/35051009 · Cited by 5,880
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
O'Brien, J. L. (2007) · Science · doi:10.1126/science.1142892 · Cited by 1,221
Pernice, W. H. P., Schuck, C., Minaeva, O., Li, M., Goltsman, G. N., Sergienko, A. V., & Tang, H. X. (2012) · Nature Communications · doi:10.1038/ncomms2307 · Cited by 477
Self-citationBonneau, D., Lobino, M., Jiang, P., Natarajan, C. M., Tanner, M. G., Hadfield, R. H., Dorenbos, S. N., Zwiller, V., Thompson, M. G., & O’Brien, J. L. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.053601 · Cited by 99
Cited by
Photonic quantum information processing: a concise review
Slussarenko, S., & Pryde, G. J. (2019) · Applied Physics Reviews · doi:10.1063/1.5115814 · Cited by 644
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
On-chip detection of non-classical light by scalable integration of single-photon detectors
Najafi, F., Mower, J., Harris, N. C., Bellei, F., Dane, A., Lee, C., Hu, X., Kharel, P., Marsili, F., Assefa, S., et al. (2015) · Nature Communications · doi:10.1038/ncomms6873 · Cited by 330
Parametric down-conversion photon-pair source on a nanophotonic chip
Guo, X., Zou, C.-L., Schuck, C., Jung, H., Cheng, R., & Tang, H. X. (2016) · Light: Science & Applications · doi:10.1038/lsa.2016.249 · Cited by 291
Self-citationPatsalas, P., Kalfagiannis, N., Kassavetis, S., Abadias, G., Bellas, D. V., Lekka, C., & Lidorikis, E. (2018) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2017.11.001 · Cited by 265
Metadata
- Authors
- Schuck, C., Pernice, W. H. P., & Tang, H. X.
- Venue
- Scientific Reports
- Published
- 2013-05-29
- Volume
- 3
- Issue
- 1
- Pages
- 1893-1893
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2004876954
- Cited by
- 141
- References
- 6
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate. https://app.cochat.ai/papers/10.1038/srep01893
- The paper
- Schuck, C., Pernice, W. H. P., & Tang, H. X. (2013). Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate. Scientific Reports. https://doi.org/10.1038/srep01893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.