Rapid on-site/in-situ detection of heavy metal ions in environmental water using a structure-switching DNA optical biosensor
Open accessThe DOI matches its Crossref record.
Abstract
A structure-switching DNA optical biosensor for rapid on-site/in situ detection of heavy metal ions is reported. Mercury ions (Hg²⁺), highly toxic and ubiquitous pollutants, were selected as model target. In this system, fluorescence-labeled DNA containing T-T mismatch structure was introduced to bind with DNA probes immobilized onto the sensor surface. In the presence of Hg²⁺, some of the fluorescence-labeled DNAs bind with Hg²⁺ to form T-Hg²⁺-T complexes through the folding of themselves into a hairpin structure and dehybridization from the sensor surface, which leads to decrease in fluorescence signal. The total analysis time for a single sample was less than 10 min with detection limit of 1.2 nM. The rapid on-site/in situ determination of Hg²⁺ was readily performed in natural water. This sensing strategy can be extended in principle to other metal ions by substituting the T-Hg²⁺-T complexes with other specificity structures that selectively bind to other analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on detection of heavy metal ions in water—An electrochemical approach
Gumpu, M. B., Sethuraman, S., Krishnan, U. M., & Rayappan, J. B. B. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.02.122 · Cited by 1,027
Recent Progress in Biosensors for Environmental Monitoring: A Review
Justino, C., Duarte, A., & Rocha-Santos, T. (2017) · Sensors · doi:10.3390/s17122918 · Cited by 456
Recent Advances in Optical Biosensors for Environmental Monitoring and Early Warning
Long, F., Zhu, A., & Shi, H. (2013) · Sensors · doi:10.3390/s131013928 · Cited by 345
Self-citationLiu, M., Wang, Z., Zong, S., Chen, H., Zhu, D., Wu, L., Hu, G., & Cui, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5006282 · Cited by 178
Metadata
- Authors
- Long, F., Zhu, A., Shi, H., Wang, H., & Liu, J.
- Venue
- Scientific Reports
- Published
- 2013-07-29
- Volume
- 3
- Issue
- 1
- Pages
- 2308-2308
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2034355138
- Cited by
- 136
- References
- 0
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid on-site/in-situ detection of heavy metal ions in environmental water using a structure-switching DNA optical biosensor. https://app.cochat.ai/papers/10.1038/srep02308
- The paper
- Long, F., Zhu, A., Shi, H., Wang, H., & Liu, J. (2013). Rapid on-site/in-situ detection of heavy metal ions in environmental water using a structure-switching DNA optical biosensor. Scientific Reports. https://doi.org/10.1038/srep02308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.