A review on detection of heavy metal ions in water—An electrochemical approach
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cadmium and lead are highly toxic, non-biodegradable, capable of bioconcentration, and in excess can severely damage the human nervous system, cardiovascular system, kidneys, and brain.
“Cadmium (Cd) and plumbum (Pb), typical heavy metals, are highly toxic, non-biodegradable, and capable of bioconcentration. In excess, they can severely damage the human nervous system, cardiovascular system, kidneys, and brain [3,4].”
From Insight into the Adsorption Behavior of Cd(II) and Pb(II) from Mud by HCl-Modified Coconut Shell Biochar: Experimental and DFT Studies (2025) · cites this paper as [4]
Cites
2 retracted
Liu, G., Lin, Y., Lin, Y.-Y., et al. (2007) · Environmental Science & Technology · doi:10.1021/es071726z · Cited by 90 · see citing works
RetractedLiu, G., Lin, Y.-Y., Wu, H., et al. (2008) · Environmental Science & Technology · doi:10.1021/es800413u · Cited by 74 · see citing works
RetractedEnvironmental applications of semiconductor photocatalysis
Hoffmann, M. R., Martin, S. T., Choi, W., & Bahnemann, D. W. (1995) · Chemical Reviews · doi:10.1021/cr00033a004 · Cited by 18,495 · see citing works
Free radicals, metals and antioxidants in oxidative stress-induced cancer
Valko, M., Rhodes, C. J., Moncol, J., Izakovic, M., & Mazur, M. (2006) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2005.12.009 · Cited by 6,680 · see citing works
Hazards of heavy metal contamination
Järup, L. (2003) · British Medical Bulletin · doi:10.1093/bmb/ldg032 · Cited by 6,508 · see citing works
Metals, Toxicity and Oxidative Stress
Valko, M., Morris, H., & Cronin, M. (2005) · Current Medicinal Chemistry · doi:10.2174/0929867053764635 · Cited by 5,018 · see citing works
Introduction and General Overview of Cyclodextrin Chemistry
Szejtli, J. (1998) · Chemical Reviews · doi:10.1021/cr970022c · Cited by 5,016 · see citing works
Cytotoxicity and Genotoxicity of Silver Nanoparticles in Human Cells
Asharani, P. V., Low, G. K. M., Hande, M. P., & Valiyaveettil, S. (2008) · ACS Nano · doi:10.1021/nn800596w · Cited by 3,714 · see citing works
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214 · see citing works
Toxic Metals and Oxidative Stress Part I: Mechanisms Involved in Me-tal induced Oxidative Damage
Nuran Ercal, B. S. P., Hande Gurer-Orhan, B. S. P., & Nukhet Aykin-Burns, B. S. P. (2001) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026013394831 · Cited by 1,944 · see citing works
Mechanisms of Nanoparticle-Induced Oxidative Stress and Toxicity
Manke, A., Wang, L., & Rojanasakul, Y. (2013) · BioMed Research International · doi:10.1155/2013/942916 · Cited by 1,736 · see citing works
The Essential Toxin: Impact of Zinc on Human Health
Plum, L. M., Rink, L., & Haase, H. (2010) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph7041342 · Cited by 1,577 · see citing works
Cadmium‐induced changes in the growth and oxidative metabolism of pea plants
Sandalio, L. M., Dalurzo, H. C., Gómez, M., Romero‐Puertas, M. C., & del Río, L. A. (2001) · Journal of Experimental Botany · doi:10.1093/jexbot/52.364.2115 · Cited by 1,422 · see citing works
Aragay, G., Pons, J., & Merkoçi, A. (2011) · Chemical Reviews · doi:10.1021/cr100383r · Cited by 1,391 · see citing works
Arsenic Exposure and Toxicology: A Historical Perspective
Hughes, M. F., Beck, B. D., Chen, Y., Lewis, A. S., & Thomas, D. J. (2011) · Toxicological Sciences · doi:10.1093/toxsci/kfr184 · Cited by 1,330 · see citing works
(2008) · PubMed · Cited by 886 · see citing works
Singh, A., Sharma, R. K., Agrawal, M., & Marshall, F. M. (2009) · Food and Chemical Toxicology · doi:10.1016/j.fct.2009.11.041 · Cited by 885 · see citing works
Molecular toxicity mechanism of nanosilver
McShan, D., Ray, P. C., & Yu, H. (2014) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2014.01.010 · Cited by 762 · see citing works
Dayan, A. D., & Paine, A. J. (2001) · Human & Experimental Toxicology · doi:10.1191/096032701682693062 · Cited by 687 · see citing works
Nanostructured metal oxide-based biosensors
Solanki, P. R., Kaushik, A. K., Agrawal, V. V., & Malhotra, B. D. (2011) · NPG Asia Materials · doi:10.1038/asiamat.2010.137 · Cited by 665 · see citing works
Flora, S. J. S. (2009) · Oxidative Medicine and Cellular Longevity · doi:10.4161/oxim.2.4.9112 · Cited by 619 · see citing works
Nanostructured Sensors for Detection of Heavy Metals: A Review
Li, M., Gou, H., Al-Ogaidi, I. A. Z., et al. (2013) · ACS Sustainable Chemistry & Engineering · doi:10.1021/sc400019a · Cited by 609 · see citing works
Oxidative Stress in Lead and Cadmium Toxicity and Its Amelioration
Patra, R. C., Rautray, A. K., & Swarup, D. (2011) · Veterinary Medicine International · doi:10.4061/2011/457327 · Cited by 579 · see citing works
Wei, Y., Gao, C., Meng, F., et al. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp209805c · Cited by 512 · see citing works
Patrick, L. (2006) · PubMed · Cited by 499 · see citing works
Induction of oxidative stress and apoptosis by silver nanoparticles in the liver of adult zebrafish
Choi, J., Kim, S., Ahn, J. H., Youn, P., Kang, J. S., Park, K., Yi, J., & Ryu, D. (2009) · Aquatic Toxicology · doi:10.1016/j.aquatox.2009.12.012 · Cited by 494 · see citing works
Anodic Stripping Voltammetry of Arsenic(III) Using Gold Nanoparticle-Modified Electrodes
Dai, X., Nekrassova, O., Hyde, M. E., et al. (2004) · Analytical Chemistry · doi:10.1021/ac049232x · Cited by 491 · see citing works
Aldad, T. S., Gan, G., Gao, X., & Taylor, H. S. (2013) · Scientific Reports · doi:10.1038/srep01320 · Cited by 486 · see citing works
Cadmium is a mutagen that acts by inhibiting mismatch repair
Jin, Y. H., Clark, A. B., Slebos, R. J. C., Al-Refai, H., Taylor, J. A., Kunkel, T. A., Resnick, M. A., & Gordenin, D. A. (2003) · Nature Genetics · doi:10.1038/ng1172 · Cited by 473 · see citing works
Liu, C., Bai, R., & Ly, Q. S. (2007) · Water Research · doi:10.1016/j.watres.2007.10.031 · Cited by 444 · see citing works
Zhang, J., Song, S., Zhang, L., Wang, L., Wu, H., Pan, D., & Fan, C. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061521a · Cited by 424 · see citing works
Metals as a cause of oxidative stress in fish: a review
Sevcikova, M., Modrá, H., Slaninova, A., & Svobodová, Z. (2011) · Veterinární Medicína · doi:10.17221/4272-vetmed · Cited by 387 · see citing works
Induction of Neuronal Apoptosis by Thiol Oxidation
Aizenman, E., Stout, A. K., Hartnett, K. A., Dineley, K. E., McLaughlin, B., & Reynolds, I. J. (2000) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2000.0751878.x · Cited by 375 · see citing works
Biosensors for direct determination of organophosphate pesticides
Mulchandani, A., Chen, W., Mulchandani, P., et al. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00126-9 · Cited by 370 · see citing works
Jena, B. K., & Raj, C. R. (2008) · Analytical Chemistry · doi:10.1021/ac071064w · Cited by 351 · see citing works
Functions and toxicity of cadmium in plants: recent advances and future prospects
TRAN, T. A., & Popova, L. P. (2013) · TURKISH JOURNAL OF BOTANY · doi:10.3906/bot-1112-16 · Cited by 340 · see citing works
Electrochemical Sensors, Biosensors and their Biomedical Applications
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373738-0.x5001-6 · Cited by 333 · see citing works
Ivask, A., Juganson, K., Bondarenko, O. M., Mortimer, M., Aruoja, V., Kasemets, K., Blinova, I., Heinlaan, M., Slaveykova, V. I., & Kahru, A. (2013) · Nanotoxicology · doi:10.3109/17435390.2013.855831 · Cited by 332 · see citing works
Xiao, J., Kuang, Q., Yang, S., Xiao, F., Wang, S., & Guo, L. (2013) · Scientific Reports · doi:10.1038/srep02300 · Cited by 332 · see citing works
Hu, K.-C., Lan, D., Li, X., & Zhang, S. (2008) · Analytical Chemistry · doi:10.1021/ac8017197 · Cited by 323 · see citing works
Daily Intake of Arsenic, Cadmium, Mercury, and Lead by Consumption of Edible Marine Species
Falcó, G., Llobet, J. M., Bocio, A., & Domingo, J. L. (2006) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0610110 · Cited by 306 · see citing works
Application of Iron Oxide Nanomaterials for the Removal of Heavy Metals
Dave, P. N., & Chopda, L. V. (2014) · Journal of Nanotechnology · doi:10.1155/2014/398569 · Cited by 305 · see citing works
Greigite: a true intermediate on the polysulfide pathway to pyrite
Hunger, S., & Benning, L. G. (2007) · Geochemical Transactions · doi:10.1186/1467-4866-8-1 · Cited by 299 · see citing works
Electrochemical DNAzyme Sensor for Lead Based on Amplification of DNA−Au Bio-Bar Codes
Shen, L., Chen, Z., Li, Y., He, S., Xie, S., Xu, X., Liang, Z., Meng, X., Li, Q., Zhu, Z., et al. (2008) · Analytical Chemistry · doi:10.1021/ac800601y · Cited by 277 · see citing works
The importance of trace metal speciation to water quality criteria
Allen, H. E., & Hansen, D. J. (1996) · Water Environment Research · doi:10.2175/106143096x127307 · Cited by 276 · see citing works
Sánchez-Rodas, D., Corns, W. T., Chen, B., et al. (2010) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b917755h · Cited by 274 · see citing works
Corbisier, P., van der Lelie, D., Borremans, B., et al. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00725-9 · Cited by 265 · see citing works
Pan, B., Qiu, H., Pan, B., Nie, G., Xiao, L., Lv, L., Zhang, W., Zhang, Q., & Zheng, S. (2009) · Water Research · doi:10.1016/j.watres.2009.10.027 · Cited by 262 · see citing works
Heavy Metal Toxicity, Part I: Arsenic and Mercury
Graeme, K. A., & Pollack, C. V. (1998) · Journal of Emergency Medicine · doi:10.1016/s0736-4679(97)00241-2 · Cited by 259 · see citing works
Patlolla, A. K., Barnes, C., Yedjou, C. G., Velma, V., & Tchounwou, P. B. (2008) · Environmental Toxicology · doi:10.1002/tox.20395 · Cited by 259 · see citing works
Franco, J. L., Posser, T., Dunkley, P. R., Dickson, P. W., Mattos, J. J., Martins, R., Bainy, A. C. D., Marques, M. R., Dafré, A. L., & Farina, M. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.05.013 · Cited by 258 · see citing works
Chen, K.-H., Lu, G., Chang, J., et al. (2012) · Analytical Chemistry · doi:10.1021/ac3000336 · Cited by 255 · see citing works
Vaiopoulou, E., & Gikas, P. (2011) · Water Research · doi:10.1016/j.watres.2011.11.024 · Cited by 255 · see citing works
Biosensors for environmental applications
Rogers, K. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96929-s · Cited by 254 · see citing works
Salimi, A., Mamkhezri, H., Hallaj, R., et al. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.08.017 · Cited by 249 · see citing works
Letelier, M. E., Lepe, A. M., Faúndez, M., et al. (2005) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2004.12.004 · Cited by 249 · see citing works
Carbon nanomaterials field-effect-transistor-based biosensors
Liu, S., & Guo, X. (2012) · NPG Asia Materials · doi:10.1038/am.2012.42 · Cited by 243 · see citing works
Monteiro, D. A., Rantin, F. T., & Kalinin, A. L. (2009) · Ecotoxicology · doi:10.1007/s10646-009-0395-1 · Cited by 242 · see citing works
Molecular Mechanisms of Toxicity of Silver Nanoparticles in Zebrafish Embryos
van Aerle, R., Lange, A., Moorhouse, A. J., Paszkiewicz, K. H., Ball, K., Johnston, B. D., De-Bastos, E. S. R., Booth, T. J., Tyler, C. R., & Santos, E. M. (2013) · Environmental Science & Technology · doi:10.1021/es401758d · Cited by 229 · see citing works
Xiao, L., Wildgoose, G. G., & Compton, R. G. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.015 · Cited by 225 · see citing works
Gao, C., Yu, X., Xiong, S., et al. (2013) · Analytical Chemistry · doi:10.1021/ac303143x · Cited by 220 · see citing works
Rajaganapa, V., Xavier, F., Sreekumar, D., & Mandal, P. K. (2011) · Journal of Environmental Science and Technology · doi:10.3923/jest.2011.234.249 · Cited by 212 · see citing works
Chouteau, C., Dzyadevych, S. V., Durrieu, C., & Chovelon, J. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.032 · Cited by 211 · see citing works
Electrochemical sensors and devices for heavy metals assay in water: the French groups' contribution
Pujol, L., Evrard, D., Serrano, K. G., Freyssinier, M., Ruffien-Cizsak, A., & Gros, P. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00019 · Cited by 207 · see citing works
Mays, D. E., & Hussam, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.05.006 · Cited by 197 · see citing works
Design and Development of Biosensors for the Detection of Heavy Metal Toxicity
Turdean, G. L. (2011) · International Journal of Electrochemistry · doi:10.4061/2011/343125 · Cited by 197 · see citing works
Sharma, P., Bihari, V., Agarwal, S. K., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047877 · Cited by 195 · see citing works
Feng, L., Wang, J., Lai, Y., et al. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.050 · Cited by 192 · see citing works
Chen, Y., Wu, F., Liu, M., Parvez, F., Slavkovich, V. N., Eunus, M., Ahmed, A., Argos, M., Islam, T., Rakibuz‐Zaman, M., et al. (2013) · Environmental Health Perspectives · doi:10.1289/ehp.1205797 · Cited by 186 · see citing works
Jin, W., Wu, G., & Chen, A. (2013) · The Analyst · doi:10.1039/c3an01614e · Cited by 185 · see citing works
Kobal, A. B., Horvat, M., Prezelj, M., et al. (2004) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/s0946-672x(04)80028-2 · Cited by 183 · see citing works
Yantasee, W., Lin, Y., Hongsirikarn, K., Fryxell, G. E., Addleman, R. S., & Timchalk, C. A. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.10190 · Cited by 181 · see citing works
Ma, J., Sengupta, M. K., Yuan, D., & Dasgupta, P. Κ. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.04.029 · Cited by 181 · see citing works
Wu, Y., Liu, L., Zhan, S., et al. (2012) · The Analyst · doi:10.1039/c2an35711a · Cited by 178 · see citing works
Antibody-based sensors for heavy metal ions
Blake, D. A., Jones, R. M., Blake, R. C., et al. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00223-8 · Cited by 177 · see citing works
XAS Speciation of Arsenic in a Hyper-Accumulating Fern
Webb, S. M., Gaillard, J., Ma, L. Q., & Tu, C. (2003) · Environmental Science & Technology · doi:10.1021/es0258475 · Cited by 174 · see citing works
Carbon Nanotubes: Potential Benefits and Risks of Nanotechnology in Nuclear Medicine
Reilly, R. M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.041723 · Cited by 172 · see citing works
Modulation of Lung Immune Response
Rogério, A. D. P., Oliveira, C. J. F., de Andrade, E. L., & Haworth, O. (2013) · BioMed Research International · doi:10.1155/2013/239020 · Cited by 171 · see citing works
Wu, D.-H., Zhang, Q., Chu, X., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.017 · Cited by 165 · see citing works
Li, X., Feng, H., Huang, M., et al. (2011) · Analytical Chemistry · doi:10.1021/ac2028886 · Cited by 160 · see citing works
Wei, W., Liu, X., Sun, P., Wang, X., Zhu, H. M., Hong, M., Mao, Z., & Zhao, J. (2014) · Environmental Science & Technology · doi:10.1021/es4046567 · Cited by 159 · see citing works
Zhou, Q., Yang, L., Wang, G., et al. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.037 · Cited by 150 · see citing works
Guidelines for the identification and management of lead exposure in pregnant and lactating women
Ettinger, A. S., & Wengrovitz, A. M. (2010) · Cited by 149 · see citing works
Arsenic induces oxidative DNA damage in mammalian cells
Kessel, M., Liu, S. X., Xu, A., Santella, R. M., & Heil, T. K. (2002) · Springer eBooks · doi:10.1007/978-1-4615-1087-1_34 · Cited by 146 · see citing works
Electrochemical Detection of Arsenic(III) Using Iridium-Implanted Boron-Doped Diamond Electrodes
Ivandini, T. A., Sato, R., Makide, Y., et al. (2006) · Analytical Chemistry · doi:10.1021/ac0519514 · Cited by 146 · see citing works
A novel graphene-DNA biosensor for selective detection of mercury ions
Zhang, Y., Zhao, H. C., Wu, Z., et al. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.013 · Cited by 146 · see citing works
Bagal-Kestwal, D., KARVE, M. S., Kakade, B. A., et al. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.027 · Cited by 145 · see citing works
V-Type Nerve Agent Detection Using a Carbon Nanotube-Based Amperometric Enzyme Electrode
Joshi, K. A., Prouza, M., Kum, M. C. M., Wang, J., Tang, J. M., Haddon, R. C., Chen, W., & Mulchandani, A. (2005) · Analytical Chemistry · doi:10.1021/ac051052f · Cited by 145 · see citing works
Liu, G., Lin, Y., Tu, Y., et al. (2005) · The Analyst · doi:10.1039/b419447k · Cited by 142 · see citing works
Aragay, G., Pons, J., & Merkoçi, A. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm03751f · Cited by 140 · see citing works
Chouteau, C., Dzyadevych, S. V., Chovelon, J., et al. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.10.012 · Cited by 138 · see citing works
Long, F., Zhu, A., Shi, H., et al. (2013) · Scientific Reports · doi:10.1038/srep02308 · Cited by 137 · see citing works
Applications of nanoscale carbon-based materials in heavy metal sensing and detection
Wanekaya, A. K. (2011) · The Analyst · doi:10.1039/c1an15574a · Cited by 137 · see citing works
Arsenic induces oxidative DNA damage in mammalian cells
Kessel, M., Liu, S. X., Xu, A., Santella, R., & Hei, T. K. (2002) · Molecular and Cellular Biochemistry · doi:10.1023/a:1015927406142 · Cited by 135 · see citing works
Wei, Y., Yang, R., Zhang, Y., et al. (2011) · Chemical Communications · doi:10.1039/c1cc14215a · Cited by 133 · see citing works
Enzyme inhibition-based biosensors and biosensing systems: questionable analytical devices
de Castro, M. D. L., & Herrera, M. C. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00175-6 · Cited by 132 · see citing works
Cytotoxic effects of intra and extracellular zinc chelation on human breast cancer cells
Hashemi, M. M., Ghavami, S., Eshraghi, M., Booy, E. P., & Łoś, M. (2006) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2006.11.010 · Cited by 130 · see citing works
Sonthalia, P., McGaw, E. A., Show, Y., et al. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.06.071 · Cited by 125 · see citing works
Soldatkin, O. O., Kucherenko, I. S., Pyeshkova, V. M., et al. (2011) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2011.08.001 · Cited by 123 · see citing works
Inhibitive determination of metal ions by an amperometric glucose oxidase biosensor
Guascito, M. R., Malitesta, C., Mazzotta, E., et al. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.11.049 · Cited by 119 · see citing works
Oxidative protein damage causes chromium toxicity in yeast
Sumner, E. R., Shanmuganathan, A., Sideri, T. C., et al. (2005) · Microbiology · doi:10.1099/mic.0.27945-0 · Cited by 118 · see citing works
Yantasee, W., Hongsirikarn, K., Warner, C. L., et al. (2008) · The Analyst · doi:10.1039/b711199a · Cited by 115 · see citing works
Heavy metal determination by biosensors based on enzyme immobilised by electropolymerisation
Malitesta, C., & Guascito, M. R. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.003 · Cited by 111 · see citing works
Gumpu, M. B., Nesakumar, N., Sethuraman, S., et al. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.04.009 · Cited by 111 · see citing works
Self-citationNriagu, J. O. (2011) · Elsevier eBooks · doi:10.1016/b978-0-444-52272-6.00675-9 · Cited by 109 · see citing works
Amperometric detection of Cu2+ by yeast biosensors using flow injection analysis (FIA)
Tag, K., Riedel, K., Bauer, H., et al. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.06.007 · Cited by 108 · see citing works
Potential diagnostic applications of biosensors: current and future directions
Song, S., Xu, H., & Fan, C. (2006) · International Journal of Nanomedicine · doi:10.2147/nano.2006.1.4.433 · Cited by 105 · see citing works
Versatile biosensor vectors for detection and quantification of mercury
Hansen, L. H., & Sørensen, S. J. (2000) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.2000.tb09413.x · Cited by 105 · see citing works
Özsöz, M., Erdem, A., Kara, P., Kerman, K., & Ozkan‐Ariksoysal, D. (2003) · Electroanalysis · doi:10.1002/elan.200390077 · Cited by 103 · see citing works
Chiba, M., Shinohara, A., Matsushita, K., et al. (1996) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.178.49 · Cited by 103 · see citing works
Mortality and cancer incidence in Swedish battery workers exposed to cadmium and nickel.
Järup, L., Bellander, T., Hogstedt, C., & Spång, G. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.11.755 · Cited by 103 · see citing works
Selective Detection of As(III) at the Au(111)-like Polycrystalline Gold Electrode
Rahman, M. R., Okajima, T., & Ohsaka, T. (2010) · Analytical Chemistry · doi:10.1021/ac101206j · Cited by 102 · see citing works
In situ evaluation of heavy metal–DNA interactions using an electrochemical DNA biosensor
Oliveira, S. C. B., Corduneanu, O., & Oliveira‐Brett, A. M. (2007) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2007.11.004 · Cited by 97 · see citing works
Maiyalagan, T. (2007) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2007.11.033 · Cited by 96 · see citing works
Methylmercury neurotoxicity & antioxidant defenses.
do Nascimento, J. L. M., Oliveira, K. R. M., Lopez, M. E. C., Macchi, B. D. M., Maués, L. A. L., Pinheiro, M. D. C. N., Silveira, L. C. L., & Herculano, A. M. (2008) · PubMed · Cited by 94 · see citing works
Steinmaus, C., George, C. M., Kalman, D. A., & Smith, A. H. (2006) · Environmental Science & Technology · doi:10.1021/es060015i · Cited by 92 · see citing works
Chitosan-transition metal ions complexes for selective arsenic(V) preconcentration
Shinde, R. N., Pandey, A. K., Acharya, R., et al. (2013) · Water Research · doi:10.1016/j.watres.2013.03.059 · Cited by 92 · see citing works
Ouyang, R., Bragg, S. A., Chambers, J. Q., & Xue, Z. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.032 · Cited by 90 · see citing works
Biosensors and Their Principles
Koyun, A., Ahlatcolu, E., & Koca, Y. (2012) · InTech eBooks · doi:10.5772/48824 · Cited by 89 · see citing works
Guerreiro, G. V., Zaitouna, A. J., & Lai, R. Y. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.12.005 · Cited by 86 · see citing works
High yield production of graphene and its improved property in detecting heavy metal ions
Wang, B., Chang, Y., & Zhi, L. (2011) · New Carbon Materials · doi:10.1016/s1872-5805(11)60064-4 · Cited by 85 · see citing works
Yao, X.-Z., Guo, Z., Yuan, Q., et al. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501617a · Cited by 84 · see citing works
Wang, L., Wang, X., Shi, G., et al. (2012) · Analytical Chemistry · doi:10.1021/ac302747f · Cited by 81 · see citing works
Y-type, C-rich DNA probe for electrochemical detection of silver ion and cysteine
Gong, H., & Li, X. (2011) · The Analyst · doi:10.1039/c1an15159b · Cited by 79 · see citing works
Takahashi, M., Figus, C., Malfatti, L., et al. (2012) · NPG Asia Materials · doi:10.1038/am.2012.40 · Cited by 79 · see citing works
Zhou, C., Jiang, W., & Via, B. K. (2014) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2014.03.038 · Cited by 78 · see citing works
Electrochemical Detection of Arsenic in Various Water Samples
Rajkumar, M., Soundappan, T., & Chen, S. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)18243-5 · Cited by 78 · see citing works
A pH-based biosensor for detection of arsenic in drinking water
de Mora, K., Joshi, N., Bálint, B. L., Ward, F. B., Elfick, A. P. D., & French, C. E. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4815-8 · Cited by 76 · see citing works
Online Monitoring of Water Toxicity by Use of Bioluminescent Reporter Bacterial Biochips
Elad, T., Almog, R., Yagur‐Kroll, S., Levkov, K., Melamed, S., Shacham‐Diamand, Y., & Belkin, S. (2011) · Environmental Science & Technology · doi:10.1021/es202465c · Cited by 76 · see citing works
Development of an Electrochemical Metal-Ion Biosensor Using Self-Assembled Peptide Nanofibrils
Viguier, B., Zór, K., Kasotakis, E., et al. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200149h · Cited by 74 · see citing works
Tekaya, N., Saiapina, O., Ouada, H. B., et al. (2012) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2012.10.001 · Cited by 74 · see citing works
Electrochemical determination of Ag-ions in environment waters and their action on plant embryos
Mikelová, R., Baloun, J., Petrlová, J., Adam, V., Havel, L., Petřek, J., Horna, A., & Kizek, R. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.12.001 · Cited by 74 · see citing works
Zhuang, J., Fu, L., Tang, D., et al. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.015 · Cited by 73 · see citing works
Merulla, D., Buffi, N., Beggah, S., Truffer, F., Geiser, M. H., Renaud, P., & van der Meer, J. R. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2012.09.002 · Cited by 72 · see citing works
You, B. R., & Park, W. H. (2012) · Oncology Reports · doi:10.3892/or.2012.1852 · Cited by 70 · see citing works
Indirect Determination of Mercury Ion by Inhibition of a Glucose Biosensor Based on ZnO Nanorods
Chey, C. O., Ibupoto, Z. H., Khun, K., et al. (2012) · Sensors · doi:10.3390/s121115063 · Cited by 70 · see citing works
Adegbesan, B. O., & Adenuga, G. A. (2007) · Biological Trace Element Research · doi:10.1007/bf02685932 · Cited by 69 · see citing works
Speciation of metals in natural waters
Millero, F. J. (2001) · Geochemical Transactions · doi:10.1186/1467-4866-2-57 · Cited by 69 · see citing works
Wang, D., Zhao, Y., Jin, H., et al. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am401205w · Cited by 68 · see citing works
Su, W., Cho, M. S., Nam, J., et al. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.031 · Cited by 67 · see citing works
Use of nanohybrid materials as electrochemical transducers for mercury sensors
Martín‐Yerga, D., González-Garcı́a, M. B., & Costa‐García, A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.02.031 · Cited by 67 · see citing works
Ion Channels and Zinc: Mechanisms of Neurotoxicity and Neurodegeneration
Morris, D. R., & Levenson, C. W. (2012) · Journal of Toxicology · doi:10.1155/2012/785647 · Cited by 65 · see citing works
Electrochemical Microsensors for the Detection of Cadmium(II) and Lead(II) Ions in Plants
Kryštofová, O., Trnková, L., Adam, V., et al. (2010) · Sensors · doi:10.3390/s100605308 · Cited by 65 · see citing works
Screen-printed electrodes for electroanalytical sensing, of chromium VI in strong acid media
Miscoria, S. A., Jacq, C., Maeder, T., et al. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.013 · Cited by 64 · see citing works
Selvaraj, S., Krishnaswamy, S., Devashya, V., et al. (2011) · Langmuir · doi:10.1021/la2029356 · Cited by 63 · see citing works
Carbon nanotube-based extraction and electrochemical detection of heavy metals
Musameh, M. M., Hickey, M. B., & Kyratzis, I. L. (2011) · Research on Chemical Intermediates · doi:10.1007/s11164-011-0307-x · Cited by 62 · see citing works
Development of urease based amperometric biosensors for the inhibitive determination of Hg (II)
Domínguez‐Renedo, O., Alonso‐Lomillo, M. A., Ferreira-Gonçalves, L., et al. (2009) · Talanta · doi:10.1016/j.talanta.2009.05.043 · Cited by 62 · see citing works
Pulsed voltammetric detection of arsenic(III) at platinum electrodes in acidic media
Williams, D. G., & Johnson, D. C. (1992) · Analytical Chemistry · doi:10.1021/ac00041a009 · Cited by 62 · see citing works
Cytochrome c biosensor for determination of trace levels of cyanide and arsenic compounds
Fuku, X. G., Iftikar, F., Hess, E. H., Iwuoha, E. I., & Baker, P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.02.025 · Cited by 61 · see citing works
Casadevall, M., Fresco, P., & Kortenkamp, A. (1999) · Chemico-Biological Interactions · doi:10.1016/s0009-2797(99)00128-3 · Cited by 61 · see citing works
Huang, M., Ding, Y., & Li, X. (2014) · ACS Combinatorial Science · doi:10.1021/co400140g · Cited by 60 · see citing works
Novel approaches to biosensors for detection of arsenic in drinking water
Joshi, N., Wang, X., Montgomery, L., et al. (2009) · Desalination · doi:10.1016/j.desal.2008.05.096 · Cited by 59 · see citing works
Screen-printed Electrochemical Sensors and Biosensors for Monitoring Metal Pollutants
Honeychurch, K. C. (2012) · Insciences Journal · doi:10.5640/insc.020101 · Cited by 57 · see citing works
Bio-Sensing of Cadmium(II) Ions Using Staphylococcus aureus
Sochor, J., Zítka, O., Hynek, D., Jílková, E., Krejčová, L., Trnková, L., Adam, V., Hubálek, J., Kynický, J., Vrba, R., et al. (2011) · Sensors · doi:10.3390/s111110638 · Cited by 57 · see citing works
de Oliveira, P. R., Lamy-Mendes, A. C., Gogola, J. L., et al. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.11.057 · Cited by 56 · see citing works
Zhang, Z., Tang, A., Liao, S., et al. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.006 · Cited by 55 · see citing works
Sadeghi, S., & Garmroodi, A. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.08.020 · Cited by 53 · see citing works
Arsenic induces DNA damage via reactive oxygen species in human cells
Li, D., Morimoto, K., Takeshita, T., et al. (2001) · Environmental Health and Preventive Medicine · doi:10.1007/bf02897306 · Cited by 53 · see citing works
Bui, M.-P. N., Li, C. A., Han, K. N., et al. (2012) · Analytical Sciences · doi:10.2116/analsci.28.699 · Cited by 52 · see citing works
Mechanism of Cadmium-Mediated Inhibition of Msh2-Msh6 Function in DNA Mismatch Repair
Wieland, M., Levin, M. K., Hingorani, K. S., et al. (2009) · Biochemistry · doi:10.1021/bi9001248 · Cited by 47 · see citing works
Electrochemical detection of DNA hybridization based on bio-bar code method
Ding, C., Zhang, Q. Y., Lin, J., & Zhang, S. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.03.015 · Cited by 46 · see citing works
Electrochemical detection of arsenic on a gold nanoparticle array
Baron, R., Šljukić, B., Salter, C., et al. (2007) · Russian Journal of Physical Chemistry A · doi:10.1134/s003602440709018x · Cited by 45 · see citing works
Chumbimuni‐Torres, K. Y., Calvo‐Marzal, P., Wang, J., et al. (2008) · Analytical Chemistry · doi:10.1021/ac800595p · Cited by 45 · see citing works
Ho, S., Wu, W.-J., Chiu, H., et al. (2011) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2011.06.007 · Cited by 44 · see citing works
Dai, X., Qiu, F., Zhou, X., et al. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.08.002 · Cited by 43 · see citing works
Domínguez‐Renedo, O., Alonso‐Lomillo, M. A., & Arcos‐Martínez, M. J. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.06.026 · Cited by 42 · see citing works
Ensafi, A. A., Amini, M., & Rezaei, B. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.12.017 · Cited by 42 · see citing works
Zhang, L., Li, D.-W., Song, W., et al. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2046408 · Cited by 42 · see citing works
Sharma, R., Goossens, B., Kun‐Rodrigues, C., Teixeira, T., Othman, N., Boone, J. Q., Jue, N. K., Obergfell, C. J., O'Neill, R. J. W., & Chikhi, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049533 · Cited by 41 · see citing works
Trnková, L., Křížková, S., Adam, V., et al. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.035 · Cited by 41 · see citing works
Zhang, Z., & Yan, J. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.06.061 · Cited by 40 · see citing works
Reliable synthesis of bismuth nanoparticles for heavy metal detection
Yang, H., Li, J., Lü, X., et al. (2013) · Materials Research Bulletin · doi:10.1016/j.materresbull.2013.08.008 · Cited by 40 · see citing works
Electrocatalytic assay of mercury(II) ions using a bifunctional oligonucleotide signal probe
Zhang, Z., Yin, J., Wu, Z., et al. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.12.008 · Cited by 39 · see citing works
Sancho, P., Troyano, A., Fernández, C., et al. (2003) · Molecular Pharmacology · doi:10.1124/mol.63.3.581 · Cited by 36 · see citing works
Voltammetric Detection of Damage to DNA by Arsenic Compounds at a DNA Biosensor
Labuda, J., Bubnicova, K. K., Kovaľová, L., et al. (2005) · Sensors · doi:10.3390/s5060411 · Cited by 36 · see citing works
Suppression of Arsenic Trioxide-induced Apoptosis in HeLa Cells by N-Acetylcysteine
Han, Y. H., Kim, S. Z., Kim, S. H., & Park, W. H. (2008) · Molecules and Cells · doi:10.1016/s1016-8478(23)13958-6 · Cited by 36 · see citing works
Potentiometric Zinc Ion Sensor Based on Honeycomb-Like NiO Nanostructures
Abbasi, M. A., Ibupoto, Z. H., Hussain, M., Khan, Y., Khan, A., Nur, O., & Willander, M. (2012) · Sensors · doi:10.3390/s121115424 · Cited by 35 · see citing works
Wang, Y., Wei, Y., Zhang, H., et al. (2011) · Medical Oncology · doi:10.1007/s12032-011-9848-5 · Cited by 34 · see citing works
Hexavalent Chromium, Yellow Water, and Cancer
Smith, A. H. (2008) · Epidemiology · doi:10.1097/ede.0b013e31815c40dc · Cited by 34 · see citing works
Simultaneous Determination of Cadmium and Lead Using PEDOT/PSS Modified Glassy Carbon Electrode
Sukeri, A., Mathiyarasu, J., Phani, K. L. N., et al. (2011) · American Journal of Analytical Chemistry · doi:10.4236/ajac.2011.24056 · Cited by 33 · see citing works
Chang, C., Lin, S., Wei, S., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5720-5 · Cited by 33 · see citing works
Biosensor to Detect Chromium in Wastewater
Nepomuscene, N. J., Daniel, D., & Krastanov, A. I. (2007) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2007.10817477 · Cited by 33 · see citing works
Oxidative stress-mediated cytotoxicity of cadmium in chicken splenic lymphocytes
Li, J., Li, S., Tang, Z., et al. (2010) · Toxicology Letters · doi:10.1016/j.toxlet.2010.03.429 · Cited by 32 · see citing works
Feier, B., Băjan, I., Fizeșan, I., et al. (2015) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)04980-5 · Cited by 32 · see citing works
Li, Y., Liu, X., Ning, X., et al. (2011) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2011.09.001 · Cited by 31 · see citing works
Microfluidic heavy metal immunoassay based on absorbance measurement
Date, Y., Terakado, S., Sasaki, K., et al. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.12.030 · Cited by 30 · see citing works
Occurrence and Mobility of Mercury in Groundwater
Julia, L., Szabó, Z., & Pamela, A. (2013) · InTech eBooks · doi:10.5772/55487 · Cited by 29 · see citing works
K'Owino, I. O., Agarwal, R., & Sadik, O. A. (2003) · Langmuir · doi:10.1021/la0265272 · Cited by 28 · see citing works
Zhao, J. T., Fan, Q. W., Zhu, S., et al. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.073 · Cited by 28 · see citing works
Křížková, S., Kryštofová, O., Trnková, L., et al. (2009) · Sensors · doi:10.3390/s90906934 · Cited by 28 · see citing works
Electrochemical preparation of copper–dendrimer nanocomposites: picomolar detection of Cu2+ ions
Berchmans, S., Vergheese, T. M., Kavitha, A. L., et al. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1723-z · Cited by 28 · see citing works
Analytical Characteristics of Electrochemical Biosensors
Stoytcheva, M., Zlatev, R. K., Velkova, Z., et al. (2009) · Portugaliae electrochimica acta · doi:10.4152/pea.200903353 · Cited by 27 · see citing works
Protein-based electrochemical biosensor for detection of silver(I) ions
Křížková, S., Húska, D., Beklová, M., et al. (2009) · Environmental Toxicology and Chemistry · doi:10.1002/etc.77 · Cited by 26 · see citing works
Srikanth, K., Ahmad, I., Rao, J. V., et al. (2014) · Comparative Biochemistry and Physiology Part C Toxicology & Pharmacology · doi:10.1016/j.cbpc.2014.02.007 · Cited by 26 · see citing works
D’Eramo, F., Silber, J. J., Arévalo, A. H., et al. (2000) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00329-6 · Cited by 25 · see citing works
Santhosh, C., Saranya, M., Ramachandran, R., et al. (2014) · Journal of Nanotechnology · doi:10.1155/2014/304526 · Cited by 25 · see citing works
Tekaya, N., Saiapina, O., Ouada, H. B., et al. (2014) · Journal of Environmental Protection · doi:10.4236/jep.2014.55047 · Cited by 25 · see citing works
Amperometric cytochrome c3-based biosensor for chromate determination
Michel, C., Battaglia‐Brunet, F., Minh, C. T., et al. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00191-x · Cited by 25 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Heavy Metal Water Pollution: A Fresh Look about Hazards, Novel and Conventional Remediation Methods
Zamora-Ledezma, C., Negrete-Bolagay, D., Figueroa, F., Zamora-Ledezma, E., Ni, M., Alexis, F., & Guerrero, V. H. (2021) · Environmental Technology & Innovation · doi:10.1016/j.eti.2021.101504 · Cited by 1,246 · see citing works
Werner, J. (2020) · Journal of Separation Science · doi:10.1002/jssc.201901184 · Cited by 38 · see citing works
Pang, X., Jiang, H., Yang, J., Zhang, C., Pang, M., Chen, R., Li, J., Sun, B., Yang, D., Su, L., et al. (2025) · Chemistry · doi:10.3390/chemistry7060202 · Cited by 7 · see citing works
- Authors
- Gumpu, M. B., Sethuraman, S., Krishnan, U. M., & Rayappan, J. B. B.
- Affiliations
- SASTRA University (IN)
- Corresponding author
- Rayappan, John Bosco Balaguru
- ORCID
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 213
- Pages
- 515-533
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2047683103
- Cited by
- 1,027
- References
- 238
- Citations by year
- 2026: 52 · 2025: 82 · 2024: 93 · 2023: 95 · 2022: 128 · 2021: 106 · 2020: 117 · 2019: 125 · 2018: 95 · 2017: 73 · 2016: 46 · 2015: 15
- FWCI
- 35.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Sensors and Actuators B Chemical (publishedVersion)
- Funders
- Department of Science and Technology, New Delhi (DST/TSG/PT/2008/28, DST/TM/WTI/2K14/197(a)(G), SR/NM/PG-16/2007, SR/FST/ETI-284/2011(C))
- Topics
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- heavy metal ions, water pollution, electrochemical biosensor, nanomaterials, arsenic, cadmium, lead, mercury, chromium, oxidative stress, carbon nanotubes, metal oxide nanoparticles, enzyme biosensor, whole-cell biosensors, nanoparticle-based sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review