Radioluminescence and photoluminescence of Th:CaF2 crystals
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We study thorium-doped CaF 2 crystals as a possible platform for optical spectroscopy of the 229 Th nuclear isomer transition. We anticipate two major sources of background signal that might cover the nuclear spectroscopy signal: VUV-photoluminescence, caused by the probe light and radioluminescence, caused by the radioactive decay of 229 Th and its daughters. We find a rich photoluminescence spectrum at wavelengths above 260 nm and radioluminescence emission above 220 nm. This is very promising, as fluorescence originating from the isomer transition, predicted at a wavelength shorter than 200 nm, could be filtered spectrally from the crystal luminescence. Furthermore, we investigate the temperature-dependent decay time of the luminescence, as well as thermoluminescence properties. Our findings allow for an immediate optimization of spectroscopy protocols for both the initial search for the nuclear transition using synchrotron radiation, as well as future optical clock operation with narrow-linewidth lasers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Nuclear laser spectroscopy of the 3.5 eV transition in Th-229
Peik, E., & Tamm, C. (2003) · Europhysics Letters (EPL) · doi:10.1209/epl/i2003-00210-x · Cited by 435
Energy Splitting of the Ground-State Doublet in the NucleusTh229
Beck, B. R., Becker, J. A., Beiersdorfer, P., Brown, G. V., Moody, K. J., Wilhelmy, J. B., Porter, F. S., Kilbourne, C. A., & Kelley, R. L. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.142501 · Cited by 290
Berengut, J. C., Dzuba, V. A., Flambaum, V. V., & Porsev, S. G. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.210801 · Cited by 127
Cited by
Direct detection of the 229Th nuclear clock transition
von der Wense, L., Seiferle, B., Laatiaoui, M., Neumayr, J. B., Maier, H.-J., Wirth, H.-F., Mokry, C., Runke, J., Eberhardt, K., Düllmann, C. E., et al. (2016) · Nature · doi:10.1038/nature17669 · Cited by 262
Laser Excitation of the Th-229 Nucleus
Tiedau, J., Okhapkin, M. V., Zhang, K., Thielking, J., Zitzer, G., Peik, E., Schaden, F., Pronebner, T., Morawetz, I., De Col, L. T., et al. (2024) · Physical Review Letters · doi:10.1103/physrevlett.132.182501 · Cited by 179
Self-citationThe thorium-229 low-energy isomer and the nuclear clock
Beeks, K., Sikorsky, T., Schumm, T., Thielking, J., Okhapkin, M. V., & Peik, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00286-6 · Cited by 127
Self-citation
Metadata
- Authors
- Stellmer, S., Schreitl, M., & Schumm, T.
- Venue
- Scientific Reports
- Published
- 2015-10-27
- Volume
- 5
- Issue
- 1
- Pages
- 15580-15580
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W1852462663
- Cited by
- 47
- References
- 4
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radioluminescence and photoluminescence of Th:CaF2 crystals. https://app.cochat.ai/papers/10.1038/srep15580
- The paper
- Stellmer, S., Schreitl, M., & Schumm, T. (2015). Radioluminescence and photoluminescence of Th:CaF2 crystals. Scientific Reports. https://doi.org/10.1038/srep15580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.