Impact of external medium conductivity on cell membrane electropermeabilization by microsecond and nanosecond electric pulses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The impact of external medium conductivity on the efficiency of the reversible permeabilisation caused by pulsed electric fields was investigated. Pulses of 12 ns, 102 ns or 100 μs were investigated. Whenever permeabilisation could be detected after the delivery of one single pulse, media of lower conductivity induced more efficient reversible permeabilisation and thus independently of the medium composition. Effect of medium conductivity can however be hidden by some saturation effects, for example when pulses are cumulated (use of trains of 8 pulses) or when the detection method is not sensitive enough. This explains the contradicting results that can be found in the literature. The new data are complementary to those of one of our previous study in which an opposite effect of the conductivity was highlighted. It stresses that the conductivity of the medium influences the reversible permeabilization by several ways. Moreover, these results clearly indicate that electropermeabilisation does not linearly depend on the energy delivered to the cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“unfortunately increasing plasmid sizes negatively affect both transfection efficiency and cell viability (15,16).”
From Easy and robust electrotransfection protocol for efficient ectopic gene expression and genome editing in human B cells (2023) · cites this paper as [15]
In the citing paper
“Moreover, these rates are attained only using small plasmids, the transfection efficiency being much lower when using larger plasmids such as those carrying CRISPR/Cas9.”
From Easy and robust electrotransfection protocol for efficient ectopic gene expression and genome editing in human B cells (2023) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pulsed electric field assisted extraction of intracellular valuables from microalgae
Goettel, M., Eing, C., Gusbeth, C., Straessner, R., & Frey, W. (2013) · Algal Research · doi:10.1016/j.algal.2013.07.004 · Cited by 313
Research works printed but not linked: 51
- Mir, L. M., Banoun, H. & Paoletti, C. Introduction of definite amounts of nonpermeant molecules into living cells after electropermeabilization: Direct access to the cytosol. Exp. Cell Res. 175, 15–25 (1988). · DOI · Paper page
- Neumann, E. Membrane electroporation and direct gene transfer. Bioelectrochem. Bioenerg. 28, 247–267 (1992). · DOI
- Teissie, J., Golzio, M. & Rols, M. P. Mechanisms of cell membrane electropermeabilization: a minireview of our present (lack of ?) knowledge. Biochim. Biophys. Acta 1724, 270–280 (2005). · DOI · Paper page
- Mir, L. M. Therapeutic perspectives of in vivo cell electropermeabilization. Bioelectrochemistry Amst. Neth. 53, 1–10 (2001). · DOI · Paper page
- Silve, A. & Mir, L. M. in Clinical Aspects of Electroporation (eds. Kee, S. T., Gehl, J. & Lee, E. W. ) 69–82 (Springer: New York,, 2011). at < http://www.springerlink.com.gate1.inist.fr/content/r86178281342200g/>.
- Mir, L. M. Nucleic acids electrotransfer-based gene therapy (electrogenetherapy): past, current and future. Mol. Biotechnol. 43, 167–176 (2009). · DOI
- Sack, M. et al. Research on Industrial-Scale Electroporation Devices Fostering the Extraction of Substances from Biological Tissue. Food Eng. Rev. 2, 147–156 (2010). · DOI
- Müller, K. J., Sukhorukov, V. L. & Zimmermann, U. Reversible electropermeabilization of mammalian cells by high-intensity, ultra-short pulses of submicrosecond duration. J. Membr. Biol. 184, 161–170 (2001). · DOI
- Pakhomov, A. G. et al. Lipid nanopores can form a stable, ion channel-like conduction pathway in cell membrane. Biochem. Biophys. Res. Commun. 385, 181–186 (2009). · DOI · Paper page
- Vernier, P. T., Sun, Y. & Gundersen, M. A. Nanoelectropulse-driven membrane perturbation and small molecule permeabilization. BMC Cell Biol. 7, 37 (2006). · DOI · Paper page
- Vernier, P. T., Sun, Y., Chen, M.-T., Gundersen, M. A. & Craviso, G. L. Nanosecond electric pulse-induced calcium entry into chromaffin cells. Bioelectrochemistry Amst. Neth. 73, 1–4 (2008). · DOI
- Silve, A., Leray, I. & Mir, L. M. Demonstration of cell membrane permeabilization to medium-sized molecules caused by a single 10ns electric pulse. Bioelectrochemistry Amst. Neth. (2011), doi: 10.1016/j.bioelechem.2011.10.002. · DOI
- Neumann, E. Membrane electroporation and direct gene transfer. Bioelectrochem. Bioenerg. 28, 247–267 (1992). · DOI
- Pucihar, G., Kotnik, T., Kanduser, M. & Miklavcic, D. The influence of medium conductivity on electropermeabilization and survival of cells in vitro. Bioelectrochemistry Amst. Neth. 54, 107–115 (2001). · DOI
- Ferreira, E. et al. Optimization of a gene electrotransfer method for mesenchymal stem cell transfection. Gene Ther. 15, 537–544 (2008). · DOI
- Antov, Y., Barbul, A., Mantsur, H. & Korenstein, R. Electroendocytosis: Exposure of Cells to Pulsed Low Electric Fields Enhances Adsorption and Uptake of Macromolecules. Biophys. J. 88, 2206–2223 (2005). · doi:10.1529/biophysj.104.051268
- Djuzenova, C. S. et al. Effect of medium conductivity and composition on the uptake of propidium iodide into electropermeabilized myeloma cells. Biochim. Biophys. Acta 1284, 143–152 (1996). · DOI
- Sukhorukov, V. L., Mussauer, H. & Zimmermann, U. The effect of electrical deformation forces on the electropermeabilization of erythrocyte membranes in low- and high-conductivity media. J. Membr. Biol. 163, 235–245 (1998). · DOI
- Mussauer, H., Sukhorukov, V. L., Haase, A. & Zimmermann, U. Resistivity of Red Blood Cells Against High-Intensity, Short-Duration Electric Field Pulses Induced by Chelating Agents. J. Membr. Biol. 170, 121–133 (1999). · DOI
- Ivorra, A., Villemejane, J. & Mir, L. M. Electrical modeling of the influence of medium conductivity on electroporation. Phys. Chem. Chem. Phys. 12, 10055 (2010). · DOI
- Schoenbach, K., Joshi, R., Beebe, S. & Baum, C. A scaling law for membrane permeabilization with nanopulses. IEEE Trans. Dielectr. Electr. Insul. 16, 1224–1235 (2009). · DOI
- Silve, A., Leray, I., Leguèbe, M., Poignard, C. & Mir, L. M. Cell membranes permeabilization by 12-ns electric pulses: Not a purely dielectric, but a charge-dependent phenomenon. Bioelectrochemistry, doi: 10.1016/j.bioelechem.2015.06.002. · DOI
- Pakhomova, O. N., Gregory, B. W., Semenov, I. & Pakhomov, A. G. Two modes of cell death caused by exposure to nanosecond pulsed electric field. PloS One 8, e70278 (2013). · doi:10.1371/journal.pone.0070278
- Morotomi-Yano, K., Akiyama, H. & Yano, K. Different involvement of extracellular calcium in two modes of cell death induced by nanosecond pulsed electric fields. Arch. Biochem. Biophys. 555-556, 47–54 (2014). · DOI
- Poddevin, B., Orlowski, S., Belehradek, J., Jr & Mir, L. M. Very high cytotoxicity of bleomycin introduced into the cytosol of cells in culture. Biochem. Pharmacol. 42 Suppl, S67–75 (1991). · DOI · Paper page
- Nesin, O. M., Pakhomova, O. N., Xiao, S. & Pakhomov, A. G. Manipulation of cell volume and membrane pore comparison following single cell permeabilization with 60- and 600-ns electric pulses. Biochim. Biophys. Acta 1808, 792–801 (2011). · DOI
- Baldwin, W. H., Gregory, B. W., Osgood, C. J., Schoenbach, K. H. & Kolb, J. F. Membrane Permeability and Cell Survival After Nanosecond Pulsed-Electric-Field Exposure #x02014;Significance of Exposure-Media Composition. IEEE Trans. Plasma Sci. 38, 2948–2953 (2010). · doi:10.1109/tps.2010.2058129
- Gabriel, B. & Teissié, J. Control by electrical parameters of short- and long-term cell death resulting from electropermeabilization of Chinese hamster ovary cells. Biochim. Biophys. Acta BBA - Mol. Cell Res. 1266, 171–178 (1995). · DOI
- Rols, M. P. & Teissié, J. Electropermeabilization of mammalian cells. Quantitative analysis of the phenomenon. Biophys. J. 58, 1089–1098 (1990). · DOI · Paper page
- Pakhomov, A. G. et al. Multiple nanosecond electric pulses increase the number but not the size of long-lived nanopores in the cell membrane. Biochim. Biophys. Acta BBA - Biomembr. 1848, 958–966 (2015). · DOI
- Rols, M.-P. & Teissié, J. Electropermeabilization of Mammalian Cells to Macromolecules: Control by Pulse Duration. Biophys. J. 75, 1415–1423 (1998). · DOI · Paper page
- Li, J. & Lin, H. Numerical simulation of molecular uptake via electroporation. Bioelectrochemistry 82, 10–21 (2011). · DOI
- Sungailaitė, S., Ruzgys, P., Šatkauskienė, I., Čepurnienė, K. & Šatkauskas, S. The dependence of efficiency of transmembrane molecular transfer using electroporation on medium viscosity. J. Gene Med. 17, 80–86 (2015). · DOI
- DeBruin, K. A. & Krassowska, W. Modeling electroporation in a single cell. I. Effects Of field strength and rest potential. Biophys. J. 77, 1213–1224 (1999). · DOI · Paper page
- Kavian, O., Leguèbe, M., Poignard, C. & Weynans, L. ‘Classical’ electropermeabilization modeling at the cell scale. J. Math. Biol. 68, 235–265 (2014). · DOI
- Leguèbe, M., Silve, A., Mir, L. M. & Poignard, C. Conducting and permeable states of cell membrane submitted to high voltage pulses: mathematical and numerical studies validated by the experiments. J. Theor. Biol. 360, 83–94 (2014). · DOI
- Winterhalter, M. & Helfrich, W. Effect of voltage on pores in membranes. Phys. Rev. A 36, 5874–5876 (1987). · DOI
- Fernández, M. L., Risk, M., Reigada, R. & Vernier, P. T. Size-controlled nanopores in lipid membranes with stabilizing electric fields. Biochem. Biophys. Res. Commun. 423, 325–330 (2012). · DOI · Paper page
- Li, J. & Lin, H. The current-voltage relation for electropores with conductivity gradients. Biomicrofluidics 4, (2010). · DOI
- Helfrich, W. Deformation of lipid bilayer spheres by electric fields. Z. Für Naturforschung Sect. C Biosci. 29, 182–183 (1974). · doi:10.1515/znc-1974-3-417
- Bryant, G. & Wolfe, J. Electromechanical stresses produced in the plasma membranes of suspended cells by applied electric fields. J. Membr. Biol. 96, 129–139 (1987). · DOI
- Isambert, H. Understanding the Electroporation of Cells and Artificial Bilayer Membranes. Phys. Rev. Lett. 80, 3404 (1998). · doi:10.1103/physrevlett.80.3404
- Riske, K. A. & Dimova, R. Electric Pulses Induce Cylindrical Deformations on Giant Vesicles in Salt Solutions. Biophys. J. 91, 1778–1786 (2006). · DOI
- Popov, S. V., Svitkina, T. M., Margolis, L. B. & Tsong, T. Y. Mechanism of cell protrusion formation in electrical field: the role of actin. Biochim. Biophys. Acta BBA - Biomembr. 1066, 151–158 (1991). · DOI
- Needham, D. & Hochmuth, R. M. Electro-mechanical permeabilization of lipid vesicles. Role of membrane tension and compressibility. Biophys. J. 55, 1001–1009 (1989). · DOI · Paper page
- Dimova, R. Recent developments in the field of bending rigidity measurements on membranes. Adv. Colloid Interface Sci. 208, 225–234 (2014). · DOI · Paper page
- Eing, C., Goettel, M., Straessner, R., Gusbeth, C. & Frey, W. Pulsed Electric Field Treatment of Microalgae -Benefits for Microalgae Biomass Processing. IEEE Trans. Plasma Sci. 41, 2901–2907 (2013). · DOI · Paper page
- Pakhomova, O. N. et al. Electroporation-induced electrosensitization. PloS One 6, e17100 (2011). · DOI
- Silve, A., Guimerà Brunet, A., Al-Sakere, B., Ivorra, A. & Mir, L. M. Comparison of the effects of the repetition rate between microsecond and nanosecond pulses: Electropermeabilization-induced electro-desensitization? Biochim. Biophys. Acta BBA - Gen. Subj. 1840, 2139–2151 (2014). · doi:10.1016/j.bbagen.2014.02.011
- Silve, A., Vézinet, R. & Mir, L. M. Nanosecond-Duration Electric Pulse Delivery In Vitro and In Vivo: Experimental Considerations. Instrum. Meas. IEEE Trans. OnPP, 1–10 (2012). · doi:10.1109/tim.2012.2182861
- Silve, A., Mir, L. M. & Vezinet, R. Implementation of a broad band, high level electric field sensor in biological exposure device. in Power Modulator and High Voltage Conference (IPMHVC), 2010 IEEE International 711 –714 (2010). doi: 10.1109/IPMHVC.2010.5958458. · DOI
Cited by
Canoy, R. J., André, F., Shmakova, A., Wiels, J., Lipinski, M., Vassetzky, Y., & Germini, D. (2023) · Gene Therapy · doi:10.1038/s41434-020-00194-x · Cited by 31
Metadata
- Authors
- Silve, A., Leray, I., Poignard, C., & Mir, L. M.
- Venue
- Scientific Reports
- Published
- 2016-02-01
- Volume
- 6
- Issue
- 1
- ISSN
- 2045-2322
- Cited by
- 87
- References
- 1
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.