Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 379

The DOI matches its Crossref record.

Correction: Corrigendum: Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity

Open access
Gartia, Manas R., Misra, Santosh K., Ye, Mao, Schwartz-Duval, Aaron, Plucinski, Lisa, Zhou, Xiangfei, Kellner, David, Labriola, Leanne T., Pan, Dipanjan·2016·Scientific Reports

Abstract

Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of the paper-based biosensor that measures the changes in electrical resistance of the enzyme-plated interdigitated electrodes to quantify the level of AA present in ocular fluid. We have demonstrated the proof-of-concept of the biosensor testing 16 clinical samples collected from aqueous humor of patients undergoing therapeutic anterior chamber paracentesis. Comparing with gold standard colorimetric assay for AA concentration, OcuCheck showed accuracy of >80%, sensitivity of >88% and specificity of >71%. At present, there are no FDA-approved POS tests that can directly measures AA concentration levels in ocular fluid. We envisage that the device can be realized as a handheld, battery powered instrument that will have high impact on glaucoma care and point-of-care diagnostics of penetrating ocular globe injuries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep20452

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 379

Metadata

Authors
Gartia, M. R., Misra, S. K., Ye, M., Schwartz-Duval, A., Plucinski, L., Zhou, X., Kellner, D., Labriola, L. T., & Pan, D.
Venue
Scientific Reports
Published
2016-02-12
Volume
6
Issue
1
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2587859961
Cited by
379
References
0
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correction: Corrigendum: Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity. https://app.cochat.ai/papers/10.1038/srep20452
The paper
Gartia, M. R., Misra, S. K., Ye, M., Schwartz-Duval, A., Plucinski, L., Zhou, X., Kellner, D., Labriola, L. T., & Pan, D. (2016). Correction: Corrigendum: Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity. Scientific Reports. https://doi.org/10.1038/srep20452

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.