Conductive resins improve charging and resolution of acquired images in electron microscopic volume imaging
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Recent advances in serial block-face imaging using scanning electron microscopy (SEM) have enabled the rapid and efficient acquisition of 3-dimensional (3D) ultrastructural information from a large volume of biological specimens including brain tissues. However, volume imaging under SEM is often hampered by sample charging and typically requires specific sample preparation to reduce charging and increase image contrast. In the present study, we introduced carbon-based conductive resins for 3D analyses of subcellular ultrastructures, using serial block-face SEM (SBF-SEM) to image samples. Conductive resins were produced by adding the carbon black filler, Ketjen black, to resins commonly used for electron microscopic observations of biological specimens. Carbon black mostly localized around tissues and did not penetrate cells, whereas the conductive resins significantly reduced the charging of samples during SBF-SEM imaging. When serial images were acquired, embedding into the conductive resins improved the resolution of images by facilitating the successful cutting of samples in SBF-SEM. These results suggest that improving the conductivities of resins with a carbon black filler is a simple and useful option for reducing charging and enhancing the resolution of images obtained for volume imaging with SEM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure
Denk, W., & Horstmann, H. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020329 · Cited by 1,644
Micheva, K. D., & Smith, S. J. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.014 · Cited by 787
Serial section scanning electron microscopy of adult brain tissue using focused ion beam milling
Knott, G., Marchman, H., Wall, D., & Lich, B. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3189-07.2008 · Cited by 692
High-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy
Tapia, J. C., Kasthuri, N., Hayworth, K. J., Schalek, R., Lichtman, J. W., Smith, S. J., & Buchanan, J. (2012) · Nature Protocols · doi:10.1038/nprot.2011.439 · Cited by 296
Hayworth, K. J., Morgan, J. L., Schalek, R., Berger, D. R., Hildebrand, D. G. C., & Lichtman, J. W. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00068 · Cited by 282
Cited by
Dual microglia effects on blood brain barrier permeability induced by systemic inflammation
Haruwaka, K., Ikegami, A., Tachibana, Y., Ohno, N., Konishi, H., Hashimoto, A., Matsumoto, M., Kato, D., Ono, R., Kiyama, H., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13812-z · Cited by 923
Self-citationVolume scanning electron microscopy for imaging biological ultrastructure
Titze, B., & Genoud, C. (2016) · Biology of the Cell · doi:10.1111/boc.201600024 · Cited by 287
“There are several approaches to eliminate or minimise charging: (1) Re-embedding the sample in a surrounding conductive medium, for example silver epoxy (Wanner et al., 2016) or resins containing carbon-based fillers (Nguyen et al., 2016).”
BackgroundElevated protein synthesis in microglia causes autism-like synaptic and behavioral aberrations
Xu, Z.-X., Kim, G. H., Tan, J.-W., Riso, A. E., Sun, Y., Xu, E. Y., Liao, G.-Y., Xu, H., Lee, S.-H., Do, N.-Y., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15530-3 · Cited by 176
Automated synapse-level reconstruction of neural circuits in the larval zebrafish brain
Svara, F., Förster, D., Kubo, F., Januszewski, M., dal Maschio, M., Schubert, P. J., Kornfeld, J., Wanner, A. A., Laurell, E., Denk, W., et al. (2022) · Nature Methods · doi:10.1038/s41592-022-01621-0 · Cited by 124
Metadata
- Authors
- Nguyen, H. B., Thai, T. Q., Saitoh, S., Wu, B., Saitoh, Y., Shimo, S., Fujitani, H., Otobe, H., & Ohno, N.
- Venue
- Scientific Reports
- Published
- 2016-03-29
- Volume
- 6
- Issue
- 1
- Pages
- 23721-23721
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2312926757
- Cited by
- 98
- References
- 5
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.