The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Narrow band perfect absorber for maximum localized magnetic and electric field enhancement and sensing applications
Open accessAbstract
Plasmonics offer an exciting way to mediate the interaction between light and matter, allowing strong field enhancement and confinement, large absorption and scattering at resonance. However, simultaneous realization of ultra-narrow band perfect absorption and electromagnetic field enhancement is challenging due to the intrinsic high optical losses and radiative damping in metals. Here, we propose an all-metal plasmonic absorber with an absorption bandwidth less than 8 nm and polarization insensitive absorptivity exceeding 99%. Unlike traditional Metal-Dielectric-Metal configurations, we demonstrate that the narrowband perfect absorption and field enhancement are ascribed to the vertical gap plasmonic mode in the deep subwavelength scale, which has a high quality factor of 120 and mode volume of about 10−4 × (λres/n)3. Based on the coupled mode theory, we verify that the diluted field enhancement is proportional to the absorption and thus perfect absorption is critical to maximum field enhancement. In addition, the proposed perfect absorber can be operated as a refractive index sensor with a sensitivity of 885 nm/RIU and figure of merit as high as 110. It provides a new design strategy for narrow band perfect absorption and local field enhancement and has potential applications in biosensors, filters and nonlinear optics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Metamaterial Electromagnetic Cloak at Microwave Frequencies
Schurig, D., Mock, J. J., Justice, B. J., Cummer, S. A., Pendry, J. B., Starr, A. F., & Smith, D. R. (2006) · Science · doi:10.1126/science.1133628 · Cited by 7,586
General properties of slow-plasmon resonant nanostructures: nano-antennas and resonators
Bozhevolnyi, S. I., & Søndergaard, T. (2007) · Optics Express · doi:10.1364/oe.15.010869 · Cited by 267
Cited by
Broadband Metamaterial Absorbers
Yu, P., Besteiro, L. V., Huang, Y., Wu, J., Fu, L., Tan, H. H., Jagadish, C., Wiederrecht, G. P., Govorov, A. O., & Wang, Z. (2019) · Advanced Optical Materials · doi:10.1002/adom.201800995 · Cited by 644
Hybrid Metamaterial Absorber Platform for Sensing of CO 2 Gas at Mid‐IR
Hasan, D., & Lee, C. (2018) · Advanced Science · doi:10.1002/advs.201700581 · Cited by 173
Metadata
- Authors
- Yong, Z., Zhang, S., Gong, C., & He, S.
- Venue
- Scientific Reports
- Published
- 2016-04-05
- Volume
- 6
- Issue
- 1
- Pages
- 24063-24063
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2224006494
- Cited by
- 198
- References
- 4
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.