NO gas sensing kinetics at room temperature under UV light irradiation of In2O3 nanostructures
Open accessThe DOI matches its Crossref record.
Abstract
In 2 O 3 nanostructure sensors were fabricated by arc-discharging a source composed of a graphite tube containing indium. The NO gas sensing properties, as well as the morphology, structure, and electrical properties, were examined at room temperature under UV light illumination. In particular, the response and recovery kinetics of the sensor at room temperature under various UV light intensities were studied. The maximum response signal was observed at an intermediate UV light intensity, which could be corroborated by a nano-size effect based on the conduction model of a resistive chemical nano sensor. The mechanism for the enhanced adsorption/desorption kinetics for NO in an air environment under UV light irradiation is discussed in detail. Furthermore, the general requirements of the sensor, including the stability, repeatability, and selectivity, are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Room-Temperature Gas Sensors Under Photoactivation: From Metal Oxides to 2D Materials
Kumar, R., Liu, X., Zhang, J., & Kumar, M. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-00503-4 · Cited by 413
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Metal oxide semiconductors for gas sensing
Goel, N., Kunal, K., Kushwaha, A., & Kumar, M. (2023) · Engineering Reports · doi:10.1002/eng2.12604 · Cited by 294
Jamil, A., Fareed, S., Afsar, F., Siddique, F., Sher, F., & Rafiq, M. A. (2019) · Materials Research Express · doi:10.1088/2053-1591/ab4452 · Cited by 7
Metadata
- Authors
- Chinh, N. D., Quang, N. D., Lee, H., Thi Hien, T., Hieu, N. M., Kim, D., Kim, C., & Kim, D.
- Venue
- Scientific Reports
- Published
- 2016-10-07
- Volume
- 6
- Issue
- 1
- Pages
- 35066-35066
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2528395482
- Cited by
- 133
- References
- 0
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.