The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Fully inkjet-printed microfluidics: a solution to low-cost rapid three-dimensional microfluidics fabrication with numerous electrical and sensing applications
Open accessAbstract
As the needs for low-cost rapidly-produced microfluidics are growing with the trend of Lab-on-a-Chip and distributed healthcare, the fully inkjet-printing of microfluidics can be a solution to it with numerous potential electrical and sensing applications. Inkjet-printing is an additive manufacturing technique featuring no material waste and a low equipment cost. Moreover, similar to other additive manufacturing techniques, inkjet-printing is easy to learn and has a high fabrication speed, while it offers generally a great planar resolution down to below 20 µ m and enables flexible designs due to its inherent thin film deposition capabilities. Due to the thin film feature, the printed objects also usually obtain a high vertical resolution (such as 4.6 µ m). This paper introduces a low-cost rapid three-dimensional fabrication process of microfluidics, that relies entirely on an inkjet-printer based single platform and can be implemented directly on top of virtually any substrates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Evaluation of 3D Printing and Its Potential Impact on Biotechnology and the Chemical Sciences
Gross, B. C., Erkal, J. L., Lockwood, S. Y., Chen, C., & Spence, D. M. (2014) · Analytical Chemistry · doi:10.1021/ac403397r · Cited by 1,746
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Cited by
Fabrication and Applications of Microfluidic Devices: A Review
Niculescu, A.-G., Chircov, C., Bîrcă, A. C., & Grumezescu, A. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042011 · Cited by 678
3D-printed sensors: Current progress and future challenges
Khosravani, M. R., & Reinicke, T. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.111916 · Cited by 331
Microfluidics Based Point‐of‐Care Diagnostics
Pandey, C. M., Augustine, S., Kumar, S., Kumar, S., Nara, S., Srivastava, S., & Malhotra, B. D. (2018) · Biotechnology Journal · doi:10.1002/biot.201700047 · Cited by 273
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Metadata
- Authors
- Su, W., Cook, B. S., Fang, Y., & Tentzeris, M. M.
- Venue
- Scientific Reports
- Published
- 2016-10-07
- Volume
- 6
- Issue
- 1
- Pages
- 35111-35111
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2529219302
- Cited by
- 162
- References
- 3
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.