Aberration-free volumetric high-speed imaging of in vivo retina
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Certain topics in research and advancements in medical diagnostics may benefit from improved temporal and spatial resolution during non-invasive optical imaging of living tissue. However, so far no imaging technique can generate entirely diffraction-limited tomographic volumes with a single data acquisition, if the target moves or changes rapidly, such as the human retina. Additionally, the presence of aberrations may represent further difficulties. We show that a simple interferometric setup–based on parallelized optical coherence tomography–acquires volumetric data with 10 billion voxels per second, exceeding previous imaging speeds by an order of magnitude. This allows us to computationally obtain and correct defocus and aberrations resulting in entirely diffraction-limited volumes. As demonstration, we imaged living human retina with clearly visible nerve fiber layer, small capillary networks, and photoreceptor cells. Furthermore, the technique can also obtain phase-sensitive volumes of other scattering structures at unprecedented acquisition speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Design and Implementation of FFTW3
Frigo, M., & Johnson, S. G. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2004.840301 · Cited by 5,086
Cited by
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
In vivo optical imaging of physiological responses to photostimulation in human photoreceptors
Hillmann, D., Spahr, H., Pfäffle, C., Sudkamp, H., Franke, G., & Hüttmann, G. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1606428113 · Cited by 227
“Proc Natl Acad Sci USA 109(19):7175–7180.”
BackgroundMethodInfluentialSelf-citationHigh-speed OCT light sources and systems [Invited]
Klein, T., & Huber, R. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000828 · Cited by 220
Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited]
Pircher, M., & Zawadzki, R. J. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002536 · Cited by 209
Metadata
- Authors
- Hillmann, D., Spahr, H., Hain, C., Sudkamp, H., Franke, G., Pfäffle, C., Winter, C., & Hüttmann, G.
- Venue
- Scientific Reports
- Published
- 2016-10-20
- Volume
- 6
- Issue
- 1
- Pages
- 35209-35209
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2386382499
- Cited by
- 163
- References
- 1
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.