The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A promising biodegradable magnesium alloy suitable for clinical vascular stent application
Open accessAbstract
We report a Mg alloy Mg-2.2Nd-0.1Zn-0.4Zr (wt.%, denoted as JDBM-2) showing great potential in clinical vascular stent application by integrating the advantages of traditional medical stainless steel and polymer. This alloy exhibits high yield strength and elongation of 276 ± 6 MPa and 34.3 ± 3.4% respectively. The JDBM-2 with a stable degradation surface results in a highly homogeneous degradation mechanism and long-term structural and mechanical durability. In vitro cytotoxicity test of the Mg extract via human vascular endothelial cells (HUVECs) indicates that the corrosion products are well tolerated by the tested cells and potentially negligible toxic effect on arterial vessel walls. This alloy also exhibits compromised foreign body response (FBR) determined by human peripheral blood derived macrophage adhesion, foreign body giant cell (FBGC) formation and inflammatory cytokine and chemokine secretion. Finally, vascular stents manufactured from the JDBM-2 were implanted into rabbits for long-term evaluation. The results confirm excellent tissue compatibility and up to 6-month structural and mechanical integrity of the stent in vivo. Thus, the JDBM-2 stent with up to 6-month structural and mechanical integrity and excellent tissue compatibility represents a major breakthrough in this field and a promising alternative to traditional medical stainless steel and polymer for the clinical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiedler, U., Reiss, Y., Scharpfenecker, M., Grunow, V., Koidl, S., Thurston, G., Gale, N. W., Witzenrath, M., Rosseau, S., Suttorp, N., et al. (2006) · Nature Medicine · doi:10.1038/nm1351 · Cited by 933
Griffin, G. K., Newton, G., Tarrio, M. L., Bu, D.-X., Maganto-Garcia, E., Azcutia, V., Alcaide, P., Grabie, N., Luscinskas, F. W., Croce, K. J., et al. (2012) · The Journal of Immunology · doi:10.4049/jimmunol.1200385 · Cited by 364
Cited by
Current status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Biodegradable magnesium‐based biomaterials: An overview of challenges and opportunities
Amukarimi, S., & Mozafari, M. (2021) · MedComm · doi:10.1002/mco2.59 · Cited by 258
Biodegradable magnesium alloys for orthopaedic applications
(2021) · PubMed Central · doi:10.12336/biomatertransl.2021.03.005 · Cited by 53
Metadata
- Authors
- Mao, L., shen, L., Chen, J., Zhang, X., Kwak, M., Wu, Y., Fan, R., Zhang, L., Pei, J., Yuan, G., Song, C., Ge, J., & Ding, W.
- Venue
- Scientific Reports
- Published
- 2017-04-11
- Volume
- 7
- Issue
- 1
- Pages
- 46343-46343
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2605927699
- Cited by
- 171
- References
- 2
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A promising biodegradable magnesium alloy suitable for clinical vascular stent application. https://app.cochat.ai/papers/10.1038/srep46343
- The paper
- Mao, L., shen, L., Chen, J., Zhang, X., Kwak, M., Wu, Y., Fan, R., Zhang, L., Pei, J., Yuan, G., Song, C., Ge, J., & Ding, W. (2017). A promising biodegradable magnesium alloy suitable for clinical vascular stent application. Scientific Reports. https://doi.org/10.1038/srep46343
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.