Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record.

Inductively Coupled Plasma Mass Spectrometry for Direct Multi-element Analysis of Diluted Human Blood and Serum

BARANY, EBBA, BERGDAHL, INGVAR A., SCHÜTZ, ANDREJS, SKERFVING, STAFFAN, OSKARSSON, AGNETA·1997·J. Anal. At. Spectrom.

Abstract

A method for the inductively coupled plasma mass spectrometry (ICP-MS) multi-element analysis of diluted human blood and serum was used for the following elements: Co, Ni, Cu, Zn, Ga, Se, Rb, Mo, Rh, Pd, Cd, Sn, Sb, W, Pt, Hg, Tl and Pb. Sample pretreatment was a simple dilution (ten times for blood and five times for serum) with a solution containing 5 g l -1 of 25% ammonia, 0.5 g l -1 Triton X-100, and 0.5 g l -1 EDTA in Millipore water. In and Sc were used as internal standards. For sample introduction a flow-injection-type technique (based on time instead of volume) was used. The determinations were carried out first in a peak-jumping mode for selected masses, and then in a scanning mode. Each determination of a preparation took 75 s. The results for reference samples agreed with recommended or certified values for Co, Cu, Zn, Rb, Cd, Tl and Pb in blood, and for Rb, Mo and Cd in serum. For Ni and Hg in blood, and Cu and Zn in serum, the results agreed with one of two reference samples. The detection limits for all these elements (except for Tl) were sufficient for analysis of samples from the general population. On the other hand, the results for Se in blood, and for Co, Ni, Se, Sn and Hg in serum did not agree with recommended or certified values. No reference samples are available for Ga, Mo, Rh, Pd, Sn, Sb, W, or Pt in blood, or for Ga, Rh, Pd, W, Pt, or Pb in serum. Generally, the limits of detection for the elements in the latter group (below 0.15 µg l -1 ) are close to or above the levels present in the general population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/a700904f

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
BARANY, E., BERGDAHL, I. A., SCHÜTZ, A., SKERFVING, S., & OSKARSSON, A.
Venue
J. Anal. At. Spectrom.
Published
1997
Volume
12
Issue
9
Pages
1005-1009
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2068950525
Cited by
192
References
0
FWCI
4.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inductively Coupled Plasma Mass Spectrometry for Direct Multi-element Analysis of Diluted Human Blood and Serum. https://app.cochat.ai/papers/10.1039/a700904f
The paper
BARANY, E., BERGDAHL, I. A., SCHÜTZ, A., SKERFVING, S., & OSKARSSON, A. (1997). Inductively Coupled Plasma Mass Spectrometry for Direct Multi-element Analysis of Diluted Human Blood and Serum. J. Anal. At. Spectrom. https://doi.org/10.1039/a700904f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.