The DOI matches its Crossref record.
Inductively Coupled Plasma Mass Spectrometry for Direct Multi-element Analysis of Diluted Human Blood and Serum
Abstract
A method for the inductively coupled plasma mass spectrometry (ICP-MS) multi-element analysis of diluted human blood and serum was used for the following elements: Co, Ni, Cu, Zn, Ga, Se, Rb, Mo, Rh, Pd, Cd, Sn, Sb, W, Pt, Hg, Tl and Pb. Sample pretreatment was a simple dilution (ten times for blood and five times for serum) with a solution containing 5 g l -1 of 25% ammonia, 0.5 g l -1 Triton X-100, and 0.5 g l -1 EDTA in Millipore water. In and Sc were used as internal standards. For sample introduction a flow-injection-type technique (based on time instead of volume) was used. The determinations were carried out first in a peak-jumping mode for selected masses, and then in a scanning mode. Each determination of a preparation took 75 s. The results for reference samples agreed with recommended or certified values for Co, Cu, Zn, Rb, Cd, Tl and Pb in blood, and for Rb, Mo and Cd in serum. For Ni and Hg in blood, and Cu and Zn in serum, the results agreed with one of two reference samples. The detection limits for all these elements (except for Tl) were sufficient for analysis of samples from the general population. On the other hand, the results for Se in blood, and for Co, Ni, Se, Sn and Hg in serum did not agree with recommended or certified values. No reference samples are available for Ga, Mo, Rh, Pd, Sn, Sb, W, or Pt in blood, or for Ga, Rh, Pd, W, Pt, or Pb in serum. Generally, the limits of detection for the elements in the latter group (below 0.15 µg l -1 ) are close to or above the levels present in the general population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tubular and Glomerular Kidney Effects in Swedish Women with Low Environmental Cadmium Exposure
Åkesson, A., Lundh, T., Vahter, M., Bjellerup, P., Lidfeldt, J., Nerbrand, C., Samsioe, G., Strömberg, U., & Skerfving, S. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8033 · Cited by 465
Self-citationOlsson, I.-M., Bensryd, I., Lundh, T., Ottosson, H., Skerfving, S., & Oskarsson, A. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.021101185 · Cited by 428
Self-citationKim, Y., Lobdell, D. T., Wright, C. W., Gocheva, V. V., Hudgens, E., & Bowler, R. M. (2015) · Biological Trace Element Research · doi:10.1007/s12011-014-0223-1 · Cited by 51
Metadata
- Authors
- BARANY, E., BERGDAHL, I. A., SCHÜTZ, A., SKERFVING, S., & OSKARSSON, A.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1997
- Volume
- 12
- Issue
- 9
- Pages
- 1005-1009
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2068950525
- Cited by
- 192
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inductively Coupled Plasma Mass Spectrometry for Direct Multi-element Analysis of Diluted Human Blood and Serum. https://app.cochat.ai/papers/10.1039/a700904f
- The paper
- BARANY, E., BERGDAHL, I. A., SCHÜTZ, A., SKERFVING, S., & OSKARSSON, A. (1997). Inductively Coupled Plasma Mass Spectrometry for Direct Multi-element Analysis of Diluted Human Blood and Serum. J. Anal. At. Spectrom. https://doi.org/10.1039/a700904f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.