The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Effect of Sample Volume on Quantitative Analysis by Solid-phase MicroextractionPart 1. Theoretical Considerations
Abstract
This paper discusses the effect of sample volume on the amount of analyte extracted from a sample by solid-phase microextraction (SPME) in two-phase (sample-fiber coating) and three-phase (sample-headspace-fiber coating) systems. Up-to-date knowledge is summarized, and new concepts are introduced. The effect of sample volume on quantification and precision of results can be neglected only in rare cases. The minimum sample volume which ensures that the amount extracted, n, is lower than 1% of the initial amount of the analyte present in the sample, as well as the volume for which exactly half of the initial amount of the analyte is extracted, have been calculated for both two- and three-phase systems. It is critical that the volumes of samples and standards are the same during analysis by SPME. Extraction kinetics in headspace analysis is dependent on the headspace capacity. If it is sufficiently large, the analyte is extracted almost exclusively from the gaseous phase, and equilibration can be very fast. On the other hand, this causes a significant loss of sensitivity. The effect of sample volume on the determination of the value of the partition coefficient, K, is also discussed. If the change in concentration of the analyte in the sample at equilibrium is not taken into account, erroneous results are obtained. Even when a proper procedure is used, there are practical limitations to the accuracy of the K value determination. Large sample volumes should always be used for K value determination, as they enable broader ranges of K values to be covered with good accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid Phase Microextraction Coupled to High-Performance Liquid Chromatography
Chen, J., & Pawliszyn, J. B. (1995) · Analytical Chemistry · doi:10.1021/ac00111a006 · Cited by 310
Górecki, T., & Pawliszyn, J. (1996) · Analytical Chemistry · doi:10.1021/ac9601270 · Cited by 101
Self-citation
Cited by
Bruheim, I., Liu, X., & Pawliszyn, J. (2003) · Analytical Chemistry · doi:10.1021/ac026162q · Cited by 471
Souza-Silva, É. A., Jiang, R., Rodríguez-Lafuente, A., Gionfriddo, E., & Pawliszyn, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.016 · Cited by 335
Farahani, H., Yamini, Y., Shariati, S., Khalili-Zanjani, M. R., & Mansour-Baghahi, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.08.001 · Cited by 74
Metadata
- Authors
- Górecki, T.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1997
- Volume
- 122
- Issue
- 10
- Pages
- 1079-1086
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1990722800
- Cited by
- 192
- References
- 2
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.