The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrothermal atomic absorption spectrometric determination of aluminium, cadmium, chromium, copper, iron, manganese, nickel and lead in olive oil
Abstract
A simple and fast procedure for the direct ETAAS determination of Al, Cd, Cr, Cu, Fe, Mn, Ni and Pb in olive oil is proposed.N,N-Hexamethylenedithiocarbamic acid, hexamethyleneammonium salt (HMDC-HMA), was used as a universal modifier with two functions: isoformation of the chemical species of the investigated elements, present in olive oil and their thermal stabilisation during the pre-treatment step. Various organic solvents were studied and 1,4-dioxane was found to be the most suitable solvent for oil dilution prior to ETAAS analysis. 1,4-Dioxane improves the decomposition of triglycerides during the pre-treatment step and permits aqueous standard solutions to be used for calibration. Uncoated graphite tubes with platforms are proposed as atomisers for the ETAAS determination of Cd, Cu, Fe, Mn and Fe, and pyrolytic graphite coated graphite tubes with grooves are the most suitable atomisers for Al, Cr and Ni. Instrumental parameters optimised according to pre-treatment and atomisation curves, obtained in the presence of the olive oil matrix and with HMDC-HMA as modifier, are presented. The proposed method permits the determination of 0.1 µg g–1 Fe, 0.05 µg g–1 Ni, 0.02 µg g–1 Al, Cu, Cr and Pb, and 0.01 µg g–1 Cd and Mn with relative standard deviations of about 8–10% for all analytes in this concentration range.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dilution of edible oils with an organic solvent or solvent mixture is simple and fast prior to atomic spectrometric determination, but it worsens the detection limit.
“Dilution of edible oils with an organic solvent (e.g. toluene, n-heptane, isopropanol, etc.) or a solvent mixture is a simple and fast procedure prior to atomic spectrometric determination, but it worsens the detection limit [15,21].”
Citations
Cites
Ashing techniques in the determination of iron and copper in palm oil
Saleh, M. I., Murray, R. S., & Chin, C. N. (1988) · Journal of the American Oil Chemists' Society · doi:10.1007/bf02542378 · Cited by 20
Flagged first, then by citations
Cited by
Sorted by citations
Karimi, M., Dadfarnia, S., Shabani, A. M. H., Tamaddon, F., & Azadi, D. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.021 · Cited by 182
Metadata
- Authors
- Karadjova, I., Zachariadis, G., Boskou, G., & Stratis, J.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1998
- Volume
- 13
- Issue
- 3
- Pages
- 201-204
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2067487850
- Cited by
- 97
- References
- 1
- Citations by year
- 2026: 1 · 2024: 3 · 2023: 2 · 2022: 5 · 2021: 3 · 2020: 1 · 2018: 2 · 2017: 4 · 2016: 3 · 2015: 5 · 2014: 3 · 2013: 6 · 2012: 7
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Analytical Atomic Spectrometry (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Spectroscopy › Laser-induced spectroscopy and plasma
- Physical Sciences › Chemistry › Analytical Chemistry › Heavy Metals in Plants
- Keywords
- olive oil, trace metal analysis, graphite furnace atomic absorption spectrometry, food contamination, cadmium, lead, nickel, iron, manganese, copper, chromium, aluminum
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review