Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record.

Application of a frequency quintupled Nd:YAG source (λ=213 nm) for laser ablation inductively coupled plasma mass spectrometric analysis of minerals

E. Jeffries, Teresa, E. Jackson, Simon, P. Longerich, Henry·1998·J. Anal. At. Spectrom.

Abstract

This paper reports the use a frequency quintupled Nd:YAG laser (λ=213 nm) for laser ablation of minerals for ICP-MS analysis. The fifth harmonic was produced by in-house modification to an existing frequency quadrupled Nd:YAG laser (λ=266 nm), using commercially available optical components. The maximum pulse energy of the 213 nm output is 7.5 mJ per pulse, based on an output of 350 mJ per pulse at 1064 nm. The pulse energy is controlled and attenuated by a wave plate and MgF2 polariser combination. The laser sampling system was coupled to an enhanced sensitivity ICP-MS system. Comparison of time resolved signals for extended analyses of several materials using 213 and 266 nm for ablation demonstrates that (1) 213 nm laser ablation greatly reduces the incidence of catastrophic ablation of strongly cleaved minerals in thin section, owing to higher absorption; (2) in each case, 213 nm laser ablation produces a longer, flatter, higher intensity signal than conventional 266 nm laser ablation, suggesting a larger volume of transportable particulate is produced; and (3) inter-element fractionation is reduced during analysis using the 213 nm laser ablation system. This study is the first reported use of frequency quintupled laser ablation microprobe (LAM)–ICP-MS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/a801328d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
E. Jeffries, T., E. Jackson, S., & P. Longerich, H.
Venue
J. Anal. At. Spectrom.
Published
1998
Volume
13
Issue
9
Pages
935-940
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2009326378
Cited by
168
References
0
FWCI
13.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of a frequency quintupled Nd:YAG source (λ=213 nm) for laser ablation inductively coupled plasma mass spectrometric analysis of minerals. https://app.cochat.ai/papers/10.1039/a801328d
The paper
E. Jeffries, T., E. Jackson, S., & P. Longerich, H. (1998). Application of a frequency quintupled Nd:YAG source (λ=213 nm) for laser ablation inductively coupled plasma mass spectrometric analysis of minerals. J. Anal. At. Spectrom. https://doi.org/10.1039/a801328d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.